Statistics
| Branch: | Tag: | Revision:

root / daemons @ 06009e27

Name Size
Makefile.am 62 Bytes
ganeti-master 5.1 kB
ganeti-noded 16.1 kB
ganeti-watcher 12.2 kB

Latest revisions

# Date Author Comment
06009e27 02/05/2008 04:12 pm Iustin Pop

Add a test opcode that sleeps for a given duration

This can be used for testing purposes.

Reviewed-by: ultrotter,imsnah

d2f311db 12/12/2007 03:13 pm Iustin Pop

Modify ‘ganeti-watcher’ to run verify-disks

This patch modifies the watcher to run the ‘gnt-cluster verify-disks’
command and to log its output (if any).

Reviewed-by: imsnah

f4bc1f2c 12/03/2007 04:03 pm Michael Hanselmann

Various code style fixes for strings.

- When line wrapping is needed, move spaces to the next line.
- Remove embedded line breaks from error messages.

Reviewed-by: schreiberal

f362096f 11/29/2007 06:03 pm Iustin Pop

Make utils.RunCmd log failures when using debug

This patch adds logging of command failures to the debug log in case the
user either started the command (gnt-*) or the node daemon with the
debug flag.

Reviewed-by: imsnah

7b195d9b 11/13/2007 09:31 pm Michael Hanselmann

Small changes and fixes in ganeti-watcher.

- Use constants for keys.
- Fix bug through which automatic instance restarts wouldn't be limited

Reviewed-by: iustinp

dfa96ded 11/05/2007 02:43 am Guido Trotter

Convert os_get to use OS rather than InvalidOS

In order to do this for simplicity we leave the OSFromDisk function as-is and
we convert the eventual exception to an OS object in ganeti-noded. The
unmangling gets simplified and so does the code for checking whether the OS is...

4e679f11 11/05/2007 02:43 am Guido Trotter

Simplify diagnose mangling/unmangling functions

The functions in ganeti-noded and rpc.py still deal with the fact that an
InvalidOS error could be returned by DiagnoseOS. As this is not the case
anymore simplify their code for the current behavior.

Reviewed-By: iustinp

3f78eef2 11/02/2007 03:44 pm Iustin Pop

Implement device to instance mapping cache

Currently, troubleshooting DRBD problems involves a manual process of going
backwards from the DRBD device to the instance that owns it.

This patch adds a weak (i.e. not guaranteed to be correct or up-to-date)
cache of device to instance. The cache should be, in normal operation,...

f3e513ad 10/29/2007 05:44 pm Iustin Pop

Implement block device renaming

This patch add code for renaming a device; more precisely, for changing
the unique_id of the device. This means:
- logical volumes, rename the volume
- drbd8, change the remote peer

This is needed for the being able to replace disks for drbd8....

153d9724 10/25/2007 02:22 pm Iustin Pop

Modify two mirror-device related rpc calls

The two calls mirror_addchild and mirror_removechild take only one child
for addition/removal. While this is enough for our md usage, for local
disk replacement in drbd8, we need to be able to specify both the data...

View revisions