This is a design document detailing the implementation of support for |
8 |
Open vSwitch in the Ganeti tool chain. |
9 |
|
10 |
Current state and shortcomings |
11 |
============================== |
12 |
|
13 |
At the moment Ganeti's support for Open vSwitch is very basic and |
14 |
limited to connecting instances to an existing vSwitch. |
15 |
|
16 |
The shortcomings of this approach are: |
17 |
|
18 |
1. The full functionality (VLANs, QoS and trunking) of Open vSwitch is not used. |
19 |
|
20 |
2. Open vSwitch cannot be managed centrally. |
21 |
|
22 |
Proposed changes |
23 |
---------------- |
24 |
1. Implement functions into gnt-network to manage Open vSwitch through Ganeti gnt-network |
25 |
should be able to create, modify and delete vSwitches. The resulting configuration shall |
26 |
automatically be done on all members of the node group. Connecting Ethernet devices to |
27 |
vSwitches should be managed through this interface as well. |
28 |
|
29 |
2. Implement VLAN-capabilities: Instances shall have additional information for every NIC: VLAN-ID |
30 |
and port type. These are used to determine their type of connection to Open vSwitch. This will |
31 |
require modifying the methods for instance creation and modification |
32 |
|
33 |
3. Implement NIC bonding: Functions to bond NICs for performance improvement, load-balancing and |
34 |
failover should be added. It is preferable to have a configuration option to determine the |
35 |
type of the trunk, as there are different types of trunks (LACP dynamic and static, different |
36 |
failover and load-balancing mechanisms) |
37 |
|
38 |
4. Set QoS level on per instance basis: Instances shall have an additional information: maximum |
39 |
bandwidth and maximum burst. This helps to balance the bandwidth needs between the VMs and to |
40 |
ensure fair sharing of the bandwidth. |
41 |
|
42 |
Configuration changes for VLANs |
43 |
+++++++++++++++++++++++++++++++ |
44 |
nicparams shall be extended by a value "vlan" that will store the VLAN information for each NIC. |
45 |
This parameter will only be used if nicparams[constants.NIC_MODE] == constants.NIC_MODE_OVS, |
46 |
since it doesn't make sense in other modes. |
47 |
|
48 |
Each VLAN the NIC belongs to shall be stored in this single value. The format of storing this information |
49 |
is the same as the one which is used in Xen 4.3, since Xen 4.3 comes with functionality to support |
50 |
OpenvSwitch. |
51 |
|
52 |
This parameter will, at first, only be implemented for Xen and will have no effects on other hypervisors. |
53 |
Support for KVM will be added in the future. |
54 |
|
55 |
Example: |
56 |
switch1 will connect the VM to the default VLAN of the switch1. |
57 |
switch1.3 means that the VM is connected to an access port of VLAN 3. |
58 |
switch1.2:10:20 means that the VM is connected to a trunk port on switch1, carrying VLANs 2, 10 and 20. |
59 |
|
60 |
This configuration string is split at the dot and stored in nicparams[constants.NIC_LINK] and |
61 |
nicparams[constants.NIC_VLAN] respectively. |
62 |
|
63 |
For Xen hypervisors, this information can be concatenated again and stored in the vif config as |
64 |
the bridge parameter and will be fully compatible with vif-openvswitch as of Xen 4.3. |
65 |
|
66 |
Users of older Xen versions should be able to grab vif-openvswitch from the Xen repo and use it |
67 |
(tested in 4.2). |
68 |
|
69 |
The differentiation between access port and trunk port is given by the number of VLANs that are |
70 |
specified. |
71 |
|
72 |
gnt-instance modify shall be able to add or remove single VLANs from the vlan string without users needing |
73 |
to specify the complete new string. |
74 |
|
75 |
Configuration changes for QoS |
76 |
+++++++++++++++++++++++++++++ |
77 |
Instances shall be extended with configuration options for |
78 |
|
79 |
- maximum bandwidth |
80 |
- maximum burst rate |
81 |
|
82 |
New configuration objects need to be created for the Open vSwitch configuration. |
83 |
|
84 |
All these configuration changes need to be made available on the whole node group. |
85 |
|
86 |
.. vim: set textwidth=72 : |
87 |
.. Local Variables: |
88 |
.. mode: rst |
89 |
.. fill-column: 72 |
90 |
.. End: |