Statistics
| Branch: | Tag: | Revision:

root / man / gnt-node.sgml @ 33ea43b6

History | View | Annotate | Download (33.5 kB)

# Date Author Comment
4c61d894 03/09/2010 06:07 pm Iustin Pop

Add the auto_promote option to cli and gnt-node

This allows one to cleanly set a node offline and promote as needed
other nodes.

Signed-off-by: Iustin Pop <>
Reviewed-by: Guido Trotter <>
Reviewed-by: Michael Hanselmann <>

f8c9fa5c 02/22/2010 02:50 pm Iustin Pop

Switch gnt-node evacuate to the new opcode

This switches gnt-node to the new opcode, and in the process also
enables multi-node arguments for it.

Signed-off-by: Iustin Pop <>
Reviewed-by: Michael Hanselmann <>

7ea7bcf6 02/09/2010 12:04 pm Iustin Pop

Add an early release lock/storage for disk replace

This patch adds an early_release parameter in the OpReplaceDisks and
OpEvacuateNode opcodes, allowing earlier release of storage and more
importantly of internal Ganeti locks.

The behaviour of the early release is that any locks and storage on all...

7e9c6a78 11/02/2009 04:14 pm Iustin Pop

Some improvements to gnt-node repair-storage

Currently the repair storage has two issues:

- down instances are aborting the operation, even though they should be
ignored (it's not technically possible to know their disk status
unless we would activate their disks)...

620a85fd 11/02/2009 10:22 am Iustin Pop

Unify the query fields for the storage framework

This patch unifies the query fields in the storage framework for all
types. Note that the information is still computed on-demand, so if e.g.
the used disk space is not requested for the ‘file’ type, it won't be...

c71a1a3d 10/28/2009 05:00 am Iustin Pop

Documentation updates

Our admin guide was very very trivial. This patch updates it to contain
advice on when to use which commands, removes the instance
administration part from the installation guide (moved to the admin
guide), and adds a walkthrough document that should be useable as a...

9b94905f 10/28/2009 03:47 am Iustin Pop

Rename the node storage commands

To reduce confusion, the following gnt-node commands are renamed:

- physical-volumes → list-storage
- modify-volume → modify-storage
- repair-volume → repair-storage

The NEWS file is update accordingly and it also gets emacs local...

edc8fc5f 09/24/2009 02:38 pm Iustin Pop

Man page updates for the uuid field

Also corrects wrong indentation in the gnt-instance.sgml file.

Signed-off-by: Iustin Pop <>
Reviewed-by: Michael Hanselmann <>

90f72445 08/17/2009 05:46 pm Iustin Pop

Add support for querying the ctime/mtime

This patch adds querying of ctime/mtime for the cluster/nodes/instances.

Signed-off-by: Iustin Pop <>
Reviewed-by: Michael Hanselmann <>

1e3463f1 08/17/2009 02:26 pm Michael Hanselmann

Implement “gnt-node repair-volume”

Signed-off-by: Michael Hanselmann <>
Reviewed-by: Iustin Pop <>

53548798 08/04/2009 02:46 pm Michael Hanselmann

gnt-node physical-volumes: Add storage type parameter

This way the user can also show storage types other than lvm-pv.

Signed-off-by: Michael Hanselmann <>
Reviewed-by: Iustin Pop <>

0e89fc2d 08/04/2009 12:45 pm Michael Hanselmann

Add “gnt-node modify-volume” command

Signed-off-by: Michael Hanselmann <>
Reviewed-by: Guido Trotter <>

4007f57d 08/03/2009 04:42 pm Michael Hanselmann

Implement “gnt-node physical-volumes” command

This command can be used to list all physical volumes on nodes.

Signed-off-by: Michael Hanselmann <>
Reviewed-by: Iustin Pop <>

539210af 07/17/2009 02:41 pm Guido Trotter

Merge branch 'next' into branch-2.1

  • next:
    Fix another issue with hypervisor_name change
    Update NEWS and version for 2.0.2 release
    Improve the description of node flags in man page
    Add enabled hypervisors to TestConfigRunner
    Add a few more checks to verify config...
2a061e15 07/17/2009 02:40 pm Guido Trotter

Merge branch 'master' into next

  • master:
    Update NEWS and version for 2.0.2 release
    Improve the description of node flags in man page
    Change default stripe count to 1
    Use full-stripe size in LVM growth
    RAPI: implement instance reinstall
253ba78f 07/16/2009 08:00 pm Raiford Storey

Improve the description of node flags in man page

[: slightly reworded the explanation for offline and
changed the commit message]
Signed-off-by: Iustin Pop <>
Reviewed-by: Iustin Pop <>

2f7140ba 07/08/2009 12:28 pm Guido Trotter

Merge branch 'next' into branch-2.1

  • next:
    Create a new --no-voting option for masterfailover
    ganeti-masterd: allow non-interactive --no-voting
    Fix pylint warnings
    Add custom pylintrc
    bootstrap: Don't leak file descriptor when generating SSL certificate...
5bbd3f7f 07/07/2009 03:51 pm Michael Hanselmann

Fix some typos

Signed-off-by: Michael Hanselmann <>
Reviewed-by: Iustin Pop <>

cc208ed0 06/29/2009 05:41 pm Guido Trotter

Merge branch 'master' into branch-2.1

  • master:
    Fix adjustement of candidates in cluster modify
    Add a new node list field
    Fix HTTP server library handling of credentials
    Fix a typo in backend.InstanceReboot docstring
    Fix handling of 'vcpus' in instance list...
c120ff34 06/29/2009 01:43 pm Iustin Pop

Add a new node list field

This patch adds a ‘role’ node list field, which shows a one-character
node status. This is a simpler way to see the node status than selecting
all the flags individually.

Signed-off-by: Iustin Pop <>
Reviewed-by: Guido Trotter <>

f5118ade 05/27/2009 01:19 pm Iustin Pop

Add a node powercycle command

This (somewhat big) patch adds support for remotely rebooting the nodes
via whatever support the hypervisor has for such a concept.

For KVM/fake (and containers in the future) this just uses sysrq plus a
‘reboot’ call if the sysrq method failed. For Xen, it first tries the...

949bdabe 04/15/2009 02:11 pm Iustin Pop

A bunch of doc and other small fixes

This patch adds a couple of both externally and internally reported
issues:
- missing SGML tags (Issue 54), report and patch by superdupont
- wrong variable used in the init.d script, report and patch by
Karsten Keil <>...

d3b4cf9f 02/12/2009 07:05 pm Iustin Pop

Update the command line scripts man pages for 2.0

This patch updates the gnt-* scripts to show the new 2.0 syntax. It's
not guaranteed to be 80% complete.

Reviewed-by: ultrotter

38d7239a 09/27/2008 06:58 pm Iustin Pop

Allow listing of the serial_no via gnt-* list

This patch adds listing of the serial_no attribute in gnt-instance and
gnt-node list, and updates to the manpages to reflect the change.

Reviewed-by: ultrotter

130a6a6f 06/22/2008 01:57 pm Iustin Pop

Add a ‘tags’ field to instance and node listing

Currently there isn't any easy way to list all nodes or instance and
their tags; you have to query each node in turn, or list all the tags
via something like “gnt-cluster search-tags '.*'”. Of course, this is...

bd028152 05/29/2008 12:59 pm Iustin Pop

Documentation: cleanup of local/remote_raid1

Since we have removed support for local and remote raid1, update the man
pages and guides to reflect the new situation.

Reviewed-by: imsnah

48c4dfa8 05/05/2008 01:02 pm Iustin Pop

Improve the gnt-* list field selection

This patch allows the '-o' option to the list subcommands to add more
fields to the default list instead of replacing the default list by
prefixing the fields list with '+'.

The patch also moves the listing (in the help output) of the default...

e7c6e02b 04/16/2008 09:22 pm Michael Hanselmann

Add --readd option to “gnt-node add”

This allows us to readd a node after it failed and required a
reinstallation or replacement.

Reviewed-by: iustinp

9b603bff 02/18/2008 12:44 pm Alexander Schreiber

Update online help and manpage to include drbd disk type.

Reviewed-by: imsnah

d8a4b51d 01/28/2008 04:32 pm Iustin Pop

Improve the documentation of query output fields

The gnt-node and gnt-instance list commands have a customizable list of
output fields, but the list is not up to date (in the man page) and not
easily understandable from the ‘--help’ output.

This patch updates the man pages and adds the available fields and...

f69dab6d 11/10/2007 07:54 pm Iustin Pop

Improve the man pages

This patch does some small fixes to the man pages and adds descriptions
for a few missing options.

Reviewed-by: ultrotter

a5bc662a 10/10/2007 02:10 pm Iustin Pop

Implement gnt-node evacuate

This patch adds a new 'evacuate' subcommand to gnt-node. The command
will do a replace disks for all instances having that node as secondary
with the new target being the new node given.

The syntax is:
gnt-node evacuate src_node target_node...

c450e9b0 10/09/2007 04:48 pm Iustin Pop

Implement node failover

This patch implements a simple failover command for failing over all
primary instances. This is just a batched form of gnt-instance failover.

Reviewed-by: imsnah

810c50b7 10/08/2007 06:12 pm Iustin Pop

Add source file option for {add,remove}-tags

This patch adds a '--from' option to the {add,remove}-tags commands that
allows the command to read from a file or from stdin (when passing a
dash for the filename).

Reviewed-by: imsnah

cc425644 10/08/2007 06:11 pm Iustin Pop

Update man pages for the tags operations

This adds documentation on the {list,add,remove}-tags commands to the
gnt-{cluster,node,instance} man pages.

Reviewed-by: imsnah

dcb93971 07/24/2007 02:45 pm Michael Hanselmann

- Implement “gnt-node volumes”
- Create all --output options using a constant
- Put node checking code from opcodes into a single function
- Do the same for output fields

Reviewed-by: iustinp

a8083063 07/16/2007 04:39 pm Iustin Pop

Initial commit.