Statistics
| Branch: | Tag: | Revision:

root / doc / design-monitoring-agent.rst @ 9805aa82

History | View | Annotate | Download (11.5 kB)

1
=======================
2
Ganeti monitoring agent
3
=======================
4

    
5
.. contents:: :depth: 4
6

    
7
This is a design document detailing the implementation of a Ganeti
8
monitoring agent report system, that can be queried by a monitoring
9
system to calculate health information for a Ganeti cluster.
10

    
11
Current state and shortcomings
12
==============================
13

    
14
There is currently no monitoring support in Ganeti. While we don't want
15
to build something like Nagios or Pacemaker as part of Ganeti, it would
16
be useful if such tools could easily extract information from a Ganeti
17
machine in order to take actions (example actions include logging an
18
outage for future reporting or alerting a person or system about it).
19

    
20
Proposed changes
21
================
22

    
23
Each Ganeti node should export a status page that can be queried by a
24
monitoring system. Such status page will be exported on a network port
25
and will be encoded in JSON (simple text) over HTTP.
26

    
27
The choice of json is obvious as we already depend on it in Ganeti and
28
thus we don't need to add extra libraries to use it, as opposed to what
29
would happen for XML or some other markup format.
30

    
31
Location of agent report
32
------------------------
33

    
34
The report will be available from all nodes, and be concerned for all
35
node-local resources. This allows more real-time information to be
36
available, at the cost of querying all nodes.
37

    
38
Information reported
39
--------------------
40

    
41
The monitoring agent system will report on the following basic information:
42

    
43
- Instance status
44
- Instance disk status
45
- Status of storage for instances
46
- Ganeti daemons status, CPU usage, memory footprint
47
- Hypervisor resources report (memory, CPU, network interfaces)
48
- Node OS resources report (memory, CPU, network interfaces)
49
- Information from a plugin system
50

    
51
Instance status
52
+++++++++++++++
53

    
54
At the moment each node knows which instances are running on it, which
55
instances it is primary for, but not the cause why an instance might not
56
be running. On the other hand we don't want to distribute full instance
57
"admin" status information to all nodes, because of the performance
58
impact this would have.
59

    
60
As such we propose that:
61

    
62
- Any operation that can affect instance status will have an optional
63
  "reason" attached to it (at opcode level). This can be used for
64
  example to distinguish an admin request, from a scheduled maintenance
65
  or an automated tool's work. If this reason is not passed, Ganeti will
66
  just use the information it has about the source of the request: for
67
  example a cli shutdown operation will have "cli:shutdown" as a reason,
68
  a cli failover operation will have "cli:failover". Operations coming
69
  from the remote API will use "rapi" instead of "cli". Of course
70
  setting a real site-specific reason is still preferred.
71
- RPCs that affect the instance status will be changed so that the
72
  "reason" and the version of the config object they ran on is passed to
73
  them. They will then export the new expected instance status, together
74
  with the associated reason and object version to the status report
75
  system, which then will export those themselves.
76

    
77
Monitoring and auditing systems can then use the reason to understand
78
the cause of an instance status, and they can use the object version to
79
understand the freshness of their data even in the absence of an atomic
80
cross-node reporting: for example if they see an instance "up" on a node
81
after seeing it running on a previous one, they can compare these values
82
to understand which data is freshest, and repoll the "older" node. Of
83
course if they keep seeing this status this represents an error (either
84
an instance continuously "flapping" between nodes, or an instance is
85
constantly up on more than one), which should be reported and acted
86
upon.
87

    
88
The instance status will be on each node, for the instances it is
89
primary for and will contain at least:
90

    
91
- The instance name
92
- The instance UUID (stable on name change)
93
- The instance running status (up or down)
94
- The uptime, as detected by the hypervisor
95
- The timestamp of last known change
96
- The timestamp of when the status was last checked (see caching, below)
97
- The last known reason for change, if any
98

    
99
More information about all the fields and their type will be available
100
in the "Format of the report" section.
101

    
102
Note that as soon as a node knows it's not the primary anymore for an
103
instance it will stop reporting status for it: this means the instance
104
will either disappear, if it has been deleted, or appear on another
105
node, if it's been moved.
106

    
107
Instance Disk status
108
++++++++++++++++++++
109

    
110
As for the instance status Ganeti has now only partial information about
111
its instance disks: in particular each node is unaware of the disk to
112
instance mapping, that exists only on the master.
113

    
114
For this design doc we plan to fix this by changing all RPCs that create
115
a backend storage or that put an already existing one in use and passing
116
the relevant instance to the node. The node can then export these to the
117
status reporting tool.
118

    
119
While we haven't implemented these RPC changes yet, we'll use confd to
120
fetch this information in the data collector.
121

    
122
Since Ganeti supports many type of disks for instances (drbd, rbd,
123
plain, file) we will export both a "generic" status which will work for
124
any type of disk and will be very opaque (at minimum just an "healthy"
125
or "error" state, plus perhaps some human readable comment and a
126
"per-type" status which will explain more about the internal details but
127
will not be compatible between different storage types (and will for
128
example export the drbd connection status, sync, and so on).
129

    
130
Status of storage for instances
131
+++++++++++++++++++++++++++++++
132

    
133
The node will also be reporting on all storage types it knows about for
134
the current node (this is right now hardcoded to the enabled storage
135
types, and in the future tied to the enabled storage pools for the
136
nodegroup). For this kind of information also we will report both a
137
generic health status (healthy or error) for each type of storage, and
138
some more generic statistics (free space, used space, total visible
139
space). In addition type specific information can be exported: for
140
example, in case of error, the nature of the error can be disclosed as a
141
type specific information. Examples of these are "backend pv
142
unavailable" for lvm storage, "unreachable" for network based storage or
143
"filesystem error" for filesystem based implementations.
144

    
145
Ganeti daemons status
146
+++++++++++++++++++++
147

    
148
Ganeti will report what information it has about its own daemons: this
149
includes memory usage, uptime, CPU usage. This should allow identifying
150
possible problems with the Ganeti system itself: for example memory
151
leaks, crashes and high resource utilization should be evident by
152
analyzing this information.
153

    
154
Ganeti daemons will also be able to export extra internal information to
155
the status reporting, through the plugin system (see below).
156

    
157
Hypervisor resources report
158
+++++++++++++++++++++++++++
159

    
160
Each hypervisor has a view of system resources that sometimes is
161
different than the one the OS sees (for example in Xen the Node OS,
162
running as Dom0, has access to only part of those resources). In this
163
section we'll report all information we can in a "non hypervisor
164
specific" way. Each hypervisor can then add extra specific information
165
that is not generic enough be abstracted.
166

    
167
Node OS resources report
168
++++++++++++++++++++++++
169

    
170
Since Ganeti assumes it's running on Linux, it's useful to export some
171
basic information as seen by the host system. This includes number and
172
status of CPUs, memory, filesystems and network intefaces as well as the
173
version of components Ganeti interacts with (Linux, drbd, hypervisor,
174
etc).
175

    
176
Note that we won't go into any hardware specific details (e.g. querying a
177
node RAID is outside the scope of this, and can be implemented as a
178
plugin) but we can easily just report the information above, since it's
179
standard enough across all systems.
180

    
181
Plugin system
182
+++++++++++++
183

    
184
The monitoring system will be equipped with a plugin system that can
185
export specific local information through it. The plugin system will be
186
in the form of either scripts whose output will be inserted in the
187
report, plain text files which will be inserted into the report, or
188
local unix or network sockets from which the information has to be read.
189
This should allow most flexibility for implementing an efficient system,
190
while being able to keep it as simple as possible.
191

    
192
The plugin system is expected to be used by local installations to
193
export any installation specific information that they want to be
194
monitored, about either hardware or software on their systems.
195

    
196

    
197
Format of the query
198
-------------------
199

    
200
The query will be an HTTP GET request on a particular port. At the
201
beginning it will only be possible to query the full status report.
202

    
203

    
204
Format of the report
205
--------------------
206

    
207
TBD (this part needs to be completed with the format of the JSON and the
208
types of the various variables exported, as they get evaluated and
209
decided)
210

    
211

    
212
Data collectors
213
---------------
214

    
215
In order to ease testing as well as to make it simple to reuse this
216
subsystem it will be possible to run just the "data collectors" on each
217
node without passing through the agent daemon. Each data collector will
218
report specific data about its subsystem and will be documented
219
separately.
220

    
221

    
222
Mode of operation
223
-----------------
224

    
225
In order to be able to report information fast the monitoring agent
226
daemon will keep an in-memory or on-disk cache of the status, which will
227
be returned when queries are made. The status system will then
228
periodically check resources to make sure the status is up to date.
229

    
230
Different parts of the report will be queried at different speeds. These
231
will depend on:
232
- how often they vary (or we expect them to vary)
233
- how fast they are to query
234
- how important their freshness is
235

    
236
Of course the last parameter is installation specific, and while we'll
237
try to have defaults, it will be configurable. The first two instead we
238
can use adaptively to query a certain resource faster or slower
239
depending on those two parameters.
240

    
241

    
242
Implementation place
243
--------------------
244

    
245
The status daemon will be implemented as a standalone Haskell daemon. In
246
the future it should be easy to merge multiple daemons into one with
247
multiple entry points, should we find out it saves resources and doesn't
248
impact functionality.
249

    
250
The libekg library should be looked at for easily providing metrics in
251
json format.
252

    
253

    
254
Implementation order
255
--------------------
256

    
257
We will implement the agent system in this order:
258

    
259
- initial example data collectors (eg. for drbd and instance status)
260
- initial daemon for exporting data
261
- RPC updates for instance status reasons and disk to instance mapping
262
- more data collectors
263
- cache layer for the daemon (if needed)
264

    
265

    
266
Future work
267
===========
268

    
269
As a future step it can be useful to "centralize" all this reporting
270
data on a single place. This for example can be just the master node, or
271
all the master candidates. We will evaluate doing this after the first
272
node-local version has been developed and tested.
273

    
274
Another possible change is replacing the "read-only" RPCs with queries
275
to the agent system, thus having only one way of collecting information
276
from the nodes from a monitoring system and for Ganeti itself.
277

    
278
One extra feature we may need is a way to query for only sub-parts of
279
the report (eg. instances status only). This can be done by passing
280
arguments to the HTTP GET, which will be defined when we get to this
281
funtionality.
282

    
283
Finally the :doc:`autorepair system design <design-autorepair>`. system
284
(see its design) can be expanded to use the monitoring agent system as a
285
source of information to decide which repairs it can perform.
286

    
287
.. vim: set textwidth=72 :
288
.. Local Variables:
289
.. mode: rst
290
.. fill-column: 72
291
.. End: