Statistics
| Branch: | Tag: | Revision:

root / lib / hypervisor / hv_kvm.py @ cc130cc7

History | View | Annotate | Download (42.9 kB)

1
#
2
#
3

    
4
# Copyright (C) 2008, 2009, 2010, 2011 Google Inc.
5
#
6
# This program is free software; you can redistribute it and/or modify
7
# it under the terms of the GNU General Public License as published by
8
# the Free Software Foundation; either version 2 of the License, or
9
# (at your option) any later version.
10
#
11
# This program is distributed in the hope that it will be useful, but
12
# WITHOUT ANY WARRANTY; without even the implied warranty of
13
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU
14
# General Public License for more details.
15
#
16
# You should have received a copy of the GNU General Public License
17
# along with this program; if not, write to the Free Software
18
# Foundation, Inc., 51 Franklin Street, Fifth Floor, Boston, MA
19
# 02110-1301, USA.
20

    
21

    
22
"""KVM hypervisor
23

24
"""
25

    
26
import errno
27
import os
28
import os.path
29
import re
30
import tempfile
31
import time
32
import logging
33
import pwd
34
import struct
35
import fcntl
36
import shutil
37

    
38
from ganeti import utils
39
from ganeti import constants
40
from ganeti import errors
41
from ganeti import serializer
42
from ganeti import objects
43
from ganeti import uidpool
44
from ganeti import ssconf
45
from ganeti.hypervisor import hv_base
46
from ganeti import netutils
47
from ganeti.utils import wrapper as utils_wrapper
48

    
49

    
50
_KVM_NETWORK_SCRIPT = constants.SYSCONFDIR + "/ganeti/kvm-vif-bridge"
51

    
52
# TUN/TAP driver constants, taken from <linux/if_tun.h>
53
# They are architecture-independent and already hardcoded in qemu-kvm source,
54
# so we can safely include them here.
55
TUNSETIFF = 0x400454ca
56
TUNGETIFF = 0x800454d2
57
TUNGETFEATURES = 0x800454cf
58
IFF_TAP = 0x0002
59
IFF_NO_PI = 0x1000
60
IFF_VNET_HDR = 0x4000
61

    
62

    
63
def _ProbeTapVnetHdr(fd):
64
  """Check whether to enable the IFF_VNET_HDR flag.
65

66
  To do this, _all_ of the following conditions must be met:
67
   1. TUNGETFEATURES ioctl() *must* be implemented
68
   2. TUNGETFEATURES ioctl() result *must* contain the IFF_VNET_HDR flag
69
   3. TUNGETIFF ioctl() *must* be implemented; reading the kernel code in
70
      drivers/net/tun.c there is no way to test this until after the tap device
71
      has been created using TUNSETIFF, and there is no way to change the
72
      IFF_VNET_HDR flag after creating the interface, catch-22! However both
73
      TUNGETIFF and TUNGETFEATURES were introduced in kernel version 2.6.27,
74
      thus we can expect TUNGETIFF to be present if TUNGETFEATURES is.
75

76
   @type fd: int
77
   @param fd: the file descriptor of /dev/net/tun
78

79
  """
80
  req = struct.pack("I", 0)
81
  try:
82
    res = fcntl.ioctl(fd, TUNGETFEATURES, req)
83
  except EnvironmentError:
84
    logging.warning("TUNGETFEATURES ioctl() not implemented")
85
    return False
86

    
87
  tunflags = struct.unpack("I", res)[0]
88
  if tunflags & IFF_VNET_HDR:
89
    return True
90
  else:
91
    logging.warning("Host does not support IFF_VNET_HDR, not enabling")
92
    return False
93

    
94

    
95
def _OpenTap(vnet_hdr=True):
96
  """Open a new tap device and return its file descriptor.
97

98
  This is intended to be used by a qemu-type hypervisor together with the -net
99
  tap,fd=<fd> command line parameter.
100

101
  @type vnet_hdr: boolean
102
  @param vnet_hdr: Enable the VNET Header
103
  @return: (ifname, tapfd)
104
  @rtype: tuple
105

106
  """
107
  try:
108
    tapfd = os.open("/dev/net/tun", os.O_RDWR)
109
  except EnvironmentError:
110
    raise errors.HypervisorError("Failed to open /dev/net/tun")
111

    
112
  flags = IFF_TAP | IFF_NO_PI
113

    
114
  if vnet_hdr and _ProbeTapVnetHdr(tapfd):
115
    flags |= IFF_VNET_HDR
116

    
117
  # The struct ifreq ioctl request (see netdevice(7))
118
  ifr = struct.pack("16sh", "", flags)
119

    
120
  try:
121
    res = fcntl.ioctl(tapfd, TUNSETIFF, ifr)
122
  except EnvironmentError:
123
    raise errors.HypervisorError("Failed to allocate a new TAP device")
124

    
125
  # Get the interface name from the ioctl
126
  ifname = struct.unpack("16sh", res)[0].strip("\x00")
127
  return (ifname, tapfd)
128

    
129

    
130
class KVMHypervisor(hv_base.BaseHypervisor):
131
  """KVM hypervisor interface"""
132
  CAN_MIGRATE = True
133

    
134
  _ROOT_DIR = constants.RUN_GANETI_DIR + "/kvm-hypervisor"
135
  _PIDS_DIR = _ROOT_DIR + "/pid" # contains live instances pids
136
  _UIDS_DIR = _ROOT_DIR + "/uid" # contains instances reserved uids
137
  _CTRL_DIR = _ROOT_DIR + "/ctrl" # contains instances control sockets
138
  _CONF_DIR = _ROOT_DIR + "/conf" # contains instances startup data
139
  _NICS_DIR = _ROOT_DIR + "/nic" # contains instances nic <-> tap associations
140
  # KVM instances with chroot enabled are started in empty chroot directories.
141
  _CHROOT_DIR = _ROOT_DIR + "/chroot" # for empty chroot directories
142
  # After an instance is stopped, its chroot directory is removed.
143
  # If the chroot directory is not empty, it can't be removed.
144
  # A non-empty chroot directory indicates a possible security incident.
145
  # To support forensics, the non-empty chroot directory is quarantined in
146
  # a separate directory, called 'chroot-quarantine'.
147
  _CHROOT_QUARANTINE_DIR = _ROOT_DIR + "/chroot-quarantine"
148
  _DIRS = [_ROOT_DIR, _PIDS_DIR, _UIDS_DIR, _CTRL_DIR, _CONF_DIR, _NICS_DIR,
149
           _CHROOT_DIR, _CHROOT_QUARANTINE_DIR]
150

    
151
  PARAMETERS = {
152
    constants.HV_KERNEL_PATH: hv_base.OPT_FILE_CHECK,
153
    constants.HV_INITRD_PATH: hv_base.OPT_FILE_CHECK,
154
    constants.HV_ROOT_PATH: hv_base.NO_CHECK,
155
    constants.HV_KERNEL_ARGS: hv_base.NO_CHECK,
156
    constants.HV_ACPI: hv_base.NO_CHECK,
157
    constants.HV_SERIAL_CONSOLE: hv_base.NO_CHECK,
158
    constants.HV_VNC_BIND_ADDRESS:
159
      (False, lambda x: (netutils.IP4Address.IsValid(x) or
160
                         utils.IsNormAbsPath(x)),
161
       "the VNC bind address must be either a valid IP address or an absolute"
162
       " pathname", None, None),
163
    constants.HV_VNC_TLS: hv_base.NO_CHECK,
164
    constants.HV_VNC_X509: hv_base.OPT_DIR_CHECK,
165
    constants.HV_VNC_X509_VERIFY: hv_base.NO_CHECK,
166
    constants.HV_VNC_PASSWORD_FILE: hv_base.OPT_FILE_CHECK,
167
    constants.HV_KVM_FLOPPY_IMAGE_PATH: hv_base.OPT_FILE_CHECK,
168
    constants.HV_CDROM_IMAGE_PATH: hv_base.OPT_FILE_CHECK,
169
    constants.HV_KVM_CDROM2_IMAGE_PATH: hv_base.OPT_FILE_CHECK,
170
    constants.HV_BOOT_ORDER:
171
      hv_base.ParamInSet(True, constants.HT_KVM_VALID_BO_TYPES),
172
    constants.HV_NIC_TYPE:
173
      hv_base.ParamInSet(True, constants.HT_KVM_VALID_NIC_TYPES),
174
    constants.HV_DISK_TYPE:
175
      hv_base.ParamInSet(True, constants.HT_KVM_VALID_DISK_TYPES),
176
    constants.HV_KVM_CDROM_DISK_TYPE:
177
      hv_base.ParamInSet(False, constants.HT_KVM_VALID_DISK_TYPES),
178
    constants.HV_USB_MOUSE:
179
      hv_base.ParamInSet(False, constants.HT_KVM_VALID_MOUSE_TYPES),
180
    constants.HV_MIGRATION_PORT: hv_base.NET_PORT_CHECK,
181
    constants.HV_MIGRATION_BANDWIDTH: hv_base.NO_CHECK,
182
    constants.HV_MIGRATION_DOWNTIME: hv_base.NO_CHECK,
183
    constants.HV_MIGRATION_MODE: hv_base.MIGRATION_MODE_CHECK,
184
    constants.HV_USE_LOCALTIME: hv_base.NO_CHECK,
185
    constants.HV_DISK_CACHE:
186
      hv_base.ParamInSet(True, constants.HT_VALID_CACHE_TYPES),
187
    constants.HV_SECURITY_MODEL:
188
      hv_base.ParamInSet(True, constants.HT_KVM_VALID_SM_TYPES),
189
    constants.HV_SECURITY_DOMAIN: hv_base.NO_CHECK,
190
    constants.HV_KVM_FLAG:
191
      hv_base.ParamInSet(False, constants.HT_KVM_FLAG_VALUES),
192
    constants.HV_VHOST_NET: hv_base.NO_CHECK,
193
    constants.HV_KVM_USE_CHROOT: hv_base.NO_CHECK,
194
    constants.HV_MEM_PATH: hv_base.OPT_DIR_CHECK,
195
    }
196

    
197
  _MIGRATION_STATUS_RE = re.compile('Migration\s+status:\s+(\w+)',
198
                                    re.M | re.I)
199
  _MIGRATION_INFO_MAX_BAD_ANSWERS = 5
200
  _MIGRATION_INFO_RETRY_DELAY = 2
201

    
202
  _VERSION_RE = re.compile(r"\b(\d+)\.(\d+)\.(\d+)\b")
203

    
204
  ANCILLARY_FILES = [
205
    _KVM_NETWORK_SCRIPT,
206
    ]
207

    
208
  def __init__(self):
209
    hv_base.BaseHypervisor.__init__(self)
210
    # Let's make sure the directories we need exist, even if the RUN_DIR lives
211
    # in a tmpfs filesystem or has been otherwise wiped out.
212
    dirs = [(dname, constants.RUN_DIRS_MODE) for dname in self._DIRS]
213
    utils.EnsureDirs(dirs)
214

    
215
  @classmethod
216
  def _InstancePidFile(cls, instance_name):
217
    """Returns the instance pidfile.
218

219
    """
220
    return utils.PathJoin(cls._PIDS_DIR, instance_name)
221

    
222
  @classmethod
223
  def _InstanceUidFile(cls, instance_name):
224
    """Returns the instance uidfile.
225

226
    """
227
    return utils.PathJoin(cls._UIDS_DIR, instance_name)
228

    
229
  @classmethod
230
  def _InstancePidInfo(cls, pid):
231
    """Check pid file for instance information.
232

233
    Check that a pid file is associated with an instance, and retrieve
234
    information from its command line.
235

236
    @type pid: string or int
237
    @param pid: process id of the instance to check
238
    @rtype: tuple
239
    @return: (instance_name, memory, vcpus)
240
    @raise errors.HypervisorError: when an instance cannot be found
241

242
    """
243
    alive = utils.IsProcessAlive(pid)
244
    if not alive:
245
      raise errors.HypervisorError("Cannot get info for pid %s" % pid)
246

    
247
    cmdline_file = utils.PathJoin("/proc", str(pid), "cmdline")
248
    try:
249
      cmdline = utils.ReadFile(cmdline_file)
250
    except EnvironmentError, err:
251
      raise errors.HypervisorError("Can't open cmdline file for pid %s: %s" %
252
                                   (pid, err))
253

    
254
    instance = None
255
    memory = 0
256
    vcpus = 0
257

    
258
    arg_list = cmdline.split('\x00')
259
    while arg_list:
260
      arg =  arg_list.pop(0)
261
      if arg == "-name":
262
        instance = arg_list.pop(0)
263
      elif arg == "-m":
264
        memory = int(arg_list.pop(0))
265
      elif arg == "-smp":
266
        vcpus = int(arg_list.pop(0))
267

    
268
    if instance is None:
269
      raise errors.HypervisorError("Pid %s doesn't contain a ganeti kvm"
270
                                   " instance" % pid)
271

    
272
    return (instance, memory, vcpus)
273

    
274
  def _InstancePidAlive(self, instance_name):
275
    """Returns the instance pidfile, pid, and liveness.
276

277
    @type instance_name: string
278
    @param instance_name: instance name
279
    @rtype: tuple
280
    @return: (pid file name, pid, liveness)
281

282
    """
283
    pidfile = self._InstancePidFile(instance_name)
284
    pid = utils.ReadPidFile(pidfile)
285

    
286
    alive = False
287
    try:
288
      cmd_instance = self._InstancePidInfo(pid)[0]
289
      alive = (cmd_instance == instance_name)
290
    except errors.HypervisorError:
291
      pass
292

    
293
    return (pidfile, pid, alive)
294

    
295
  def _CheckDown(self, instance_name):
296
    """Raises an error unless the given instance is down.
297

298
    """
299
    alive = self._InstancePidAlive(instance_name)[2]
300
    if alive:
301
      raise errors.HypervisorError("Failed to start instance %s: %s" %
302
                                   (instance_name, "already running"))
303

    
304
  @classmethod
305
  def _InstanceMonitor(cls, instance_name):
306
    """Returns the instance monitor socket name
307

308
    """
309
    return utils.PathJoin(cls._CTRL_DIR, "%s.monitor" % instance_name)
310

    
311
  @classmethod
312
  def _InstanceSerial(cls, instance_name):
313
    """Returns the instance serial socket name
314

315
    """
316
    return utils.PathJoin(cls._CTRL_DIR, "%s.serial" % instance_name)
317

    
318
  @staticmethod
319
  def _SocatUnixConsoleParams():
320
    """Returns the correct parameters for socat
321

322
    If we have a new-enough socat we can use raw mode with an escape character.
323

324
    """
325
    if constants.SOCAT_USE_ESCAPE:
326
      return "raw,echo=0,escape=%s" % constants.SOCAT_ESCAPE_CODE
327
    else:
328
      return "echo=0,icanon=0"
329

    
330
  @classmethod
331
  def _InstanceKVMRuntime(cls, instance_name):
332
    """Returns the instance KVM runtime filename
333

334
    """
335
    return utils.PathJoin(cls._CONF_DIR, "%s.runtime" % instance_name)
336

    
337
  @classmethod
338
  def _InstanceChrootDir(cls, instance_name):
339
    """Returns the name of the KVM chroot dir of the instance
340

341
    """
342
    return utils.PathJoin(cls._CHROOT_DIR, instance_name)
343

    
344
  @classmethod
345
  def _InstanceNICDir(cls, instance_name):
346
    """Returns the name of the directory holding the tap device files for a
347
    given instance.
348

349
    """
350
    return utils.PathJoin(cls._NICS_DIR, instance_name)
351

    
352
  @classmethod
353
  def _InstanceNICFile(cls, instance_name, seq):
354
    """Returns the name of the file containing the tap device for a given NIC
355

356
    """
357
    return utils.PathJoin(cls._InstanceNICDir(instance_name), str(seq))
358

    
359
  @classmethod
360
  def _TryReadUidFile(cls, uid_file):
361
    """Try to read a uid file
362

363
    """
364
    if os.path.exists(uid_file):
365
      try:
366
        uid = int(utils.ReadOneLineFile(uid_file))
367
        return uid
368
      except EnvironmentError:
369
        logging.warning("Can't read uid file", exc_info=True)
370
      except (TypeError, ValueError):
371
        logging.warning("Can't parse uid file contents", exc_info=True)
372
    return None
373

    
374
  @classmethod
375
  def _RemoveInstanceRuntimeFiles(cls, pidfile, instance_name):
376
    """Removes an instance's rutime sockets/files/dirs.
377

378
    """
379
    utils.RemoveFile(pidfile)
380
    utils.RemoveFile(cls._InstanceMonitor(instance_name))
381
    utils.RemoveFile(cls._InstanceSerial(instance_name))
382
    utils.RemoveFile(cls._InstanceKVMRuntime(instance_name))
383
    uid_file = cls._InstanceUidFile(instance_name)
384
    uid = cls._TryReadUidFile(uid_file)
385
    utils.RemoveFile(uid_file)
386
    if uid is not None:
387
      uidpool.ReleaseUid(uid)
388
    try:
389
      shutil.rmtree(cls._InstanceNICDir(instance_name))
390
    except OSError, err:
391
      if err.errno != errno.ENOENT:
392
        raise
393
    try:
394
      chroot_dir = cls._InstanceChrootDir(instance_name)
395
      utils.RemoveDir(chroot_dir)
396
    except OSError, err:
397
      if err.errno == errno.ENOTEMPTY:
398
        # The chroot directory is expected to be empty, but it isn't.
399
        new_chroot_dir = tempfile.mkdtemp(dir=cls._CHROOT_QUARANTINE_DIR,
400
                                          prefix="%s-%s-" %
401
                                          (instance_name,
402
                                           utils.TimestampForFilename()))
403
        logging.warning("The chroot directory of instance %s can not be"
404
                        " removed as it is not empty. Moving it to the"
405
                        " quarantine instead. Please investigate the"
406
                        " contents (%s) and clean up manually",
407
                        instance_name, new_chroot_dir)
408
        utils.RenameFile(chroot_dir, new_chroot_dir)
409
      else:
410
        raise
411

    
412
  @staticmethod
413
  def _ConfigureNIC(instance, seq, nic, tap):
414
    """Run the network configuration script for a specified NIC
415

416
    @param instance: instance we're acting on
417
    @type instance: instance object
418
    @param seq: nic sequence number
419
    @type seq: int
420
    @param nic: nic we're acting on
421
    @type nic: nic object
422
    @param tap: the host's tap interface this NIC corresponds to
423
    @type tap: str
424

425
    """
426

    
427
    if instance.tags:
428
      tags = " ".join(instance.tags)
429
    else:
430
      tags = ""
431

    
432
    env = {
433
      "PATH": "%s:/sbin:/usr/sbin" % os.environ["PATH"],
434
      "INSTANCE": instance.name,
435
      "MAC": nic.mac,
436
      "MODE": nic.nicparams[constants.NIC_MODE],
437
      "INTERFACE": tap,
438
      "INTERFACE_INDEX": str(seq),
439
      "TAGS": tags,
440
    }
441

    
442
    if nic.ip:
443
      env["IP"] = nic.ip
444

    
445
    if nic.nicparams[constants.NIC_LINK]:
446
      env["LINK"] = nic.nicparams[constants.NIC_LINK]
447

    
448
    if nic.nicparams[constants.NIC_MODE] == constants.NIC_MODE_BRIDGED:
449
      env["BRIDGE"] = nic.nicparams[constants.NIC_LINK]
450

    
451
    result = utils.RunCmd([constants.KVM_IFUP, tap], env=env)
452
    if result.failed:
453
      raise errors.HypervisorError("Failed to configure interface %s: %s."
454
                                   " Network configuration script output: %s" %
455
                                   (tap, result.fail_reason, result.output))
456

    
457
  def ListInstances(self):
458
    """Get the list of running instances.
459

460
    We can do this by listing our live instances directory and
461
    checking whether the associated kvm process is still alive.
462

463
    """
464
    result = []
465
    for name in os.listdir(self._PIDS_DIR):
466
      if self._InstancePidAlive(name)[2]:
467
        result.append(name)
468
    return result
469

    
470
  def GetInstanceInfo(self, instance_name):
471
    """Get instance properties.
472

473
    @type instance_name: string
474
    @param instance_name: the instance name
475
    @rtype: tuple of strings
476
    @return: (name, id, memory, vcpus, stat, times)
477

478
    """
479
    _, pid, alive = self._InstancePidAlive(instance_name)
480
    if not alive:
481
      return None
482

    
483
    _, memory, vcpus = self._InstancePidInfo(pid)
484
    stat = "---b-"
485
    times = "0"
486

    
487
    return (instance_name, pid, memory, vcpus, stat, times)
488

    
489
  def GetAllInstancesInfo(self):
490
    """Get properties of all instances.
491

492
    @return: list of tuples (name, id, memory, vcpus, stat, times)
493

494
    """
495
    data = []
496
    for name in os.listdir(self._PIDS_DIR):
497
      try:
498
        info = self.GetInstanceInfo(name)
499
      except errors.HypervisorError:
500
        continue
501
      if info:
502
        data.append(info)
503
    return data
504

    
505
  def _GenerateKVMRuntime(self, instance, block_devices):
506
    """Generate KVM information to start an instance.
507

508
    """
509
    pidfile  = self._InstancePidFile(instance.name)
510
    kvm = constants.KVM_PATH
511
    kvm_cmd = [kvm]
512
    # used just by the vnc server, if enabled
513
    kvm_cmd.extend(['-name', instance.name])
514
    kvm_cmd.extend(['-m', instance.beparams[constants.BE_MEMORY]])
515
    kvm_cmd.extend(['-smp', instance.beparams[constants.BE_VCPUS]])
516
    kvm_cmd.extend(['-pidfile', pidfile])
517
    kvm_cmd.extend(['-daemonize'])
518
    if not instance.hvparams[constants.HV_ACPI]:
519
      kvm_cmd.extend(['-no-acpi'])
520

    
521
    hvp = instance.hvparams
522
    boot_disk = hvp[constants.HV_BOOT_ORDER] == constants.HT_BO_DISK
523
    boot_cdrom = hvp[constants.HV_BOOT_ORDER] == constants.HT_BO_CDROM
524
    boot_floppy = hvp[constants.HV_BOOT_ORDER] == constants.HT_BO_FLOPPY
525
    boot_network = hvp[constants.HV_BOOT_ORDER] == constants.HT_BO_NETWORK
526

    
527
    if hvp[constants.HV_KVM_FLAG] == constants.HT_KVM_ENABLED:
528
      kvm_cmd.extend(["-enable-kvm"])
529
    elif hvp[constants.HV_KVM_FLAG] == constants.HT_KVM_DISABLED:
530
      kvm_cmd.extend(["-disable-kvm"])
531

    
532
    if boot_network:
533
      kvm_cmd.extend(['-boot', 'n'])
534

    
535
    disk_type = hvp[constants.HV_DISK_TYPE]
536
    if disk_type == constants.HT_DISK_PARAVIRTUAL:
537
      if_val = ',if=virtio'
538
    else:
539
      if_val = ',if=%s' % disk_type
540
    # Cache mode
541
    disk_cache = hvp[constants.HV_DISK_CACHE]
542
    if instance.disk_template in constants.DTS_EXT_MIRROR:
543
      if disk_cache != "none":
544
        # TODO: make this a hard error, instead of a silent overwrite
545
        logging.warning("KVM: overriding disk_cache setting '%s' with 'none'"
546
                        " to prevent shared storage corruption on migration",
547
                        disk_cache)
548
      cache_val = ",cache=none"
549
    elif disk_cache != constants.HT_CACHE_DEFAULT:
550
      cache_val = ",cache=%s" % disk_cache
551
    else:
552
      cache_val = ""
553
    for cfdev, dev_path in block_devices:
554
      if cfdev.mode != constants.DISK_RDWR:
555
        raise errors.HypervisorError("Instance has read-only disks which"
556
                                     " are not supported by KVM")
557
      # TODO: handle FD_LOOP and FD_BLKTAP (?)
558
      if boot_disk:
559
        kvm_cmd.extend(['-boot', 'c'])
560
        if disk_type != constants.HT_DISK_IDE:
561
          boot_val = ',boot=on'
562
        else:
563
          boot_val = ''
564
        # We only boot from the first disk
565
        boot_disk = False
566
      else:
567
        boot_val = ''
568

    
569
      drive_val = 'file=%s,format=raw%s%s%s' % (dev_path, if_val, boot_val,
570
                                                cache_val)
571
      kvm_cmd.extend(['-drive', drive_val])
572

    
573
    #Now we can specify a different device type for CDROM devices.
574
    cdrom_disk_type = hvp[constants.HV_KVM_CDROM_DISK_TYPE]
575
    if not cdrom_disk_type:
576
      cdrom_disk_type = disk_type
577

    
578
    iso_image = hvp[constants.HV_CDROM_IMAGE_PATH]
579
    if iso_image:
580
      options = ',format=raw,media=cdrom'
581
      if boot_cdrom:
582
        kvm_cmd.extend(['-boot', 'd'])
583
        if cdrom_disk_type != constants.HT_DISK_IDE:
584
          options = '%s,boot=on,if=%s' % (options, constants.HT_DISK_IDE)
585
        else:
586
          options = '%s,boot=on' % options
587
      else:
588
        if cdrom_disk_type == constants.HT_DISK_PARAVIRTUAL:
589
          if_val = ',if=virtio'
590
        else:
591
          if_val = ',if=%s' % cdrom_disk_type
592
        options = '%s%s' % (options, if_val)
593
      drive_val = 'file=%s%s' % (iso_image, options)
594
      kvm_cmd.extend(['-drive', drive_val])
595

    
596
    iso_image2 = hvp[constants.HV_KVM_CDROM2_IMAGE_PATH]
597
    if iso_image2:
598
      options = ',format=raw,media=cdrom'
599
      if cdrom_disk_type == constants.HT_DISK_PARAVIRTUAL:
600
        if_val = ',if=virtio'
601
      else:
602
        if_val = ',if=%s' % cdrom_disk_type
603
      options = '%s%s' % (options, if_val)
604
      drive_val = 'file=%s%s' % (iso_image2, options)
605
      kvm_cmd.extend(['-drive', drive_val])
606

    
607
    floppy_image = hvp[constants.HV_KVM_FLOPPY_IMAGE_PATH]
608
    if floppy_image:
609
      options = ',format=raw,media=disk'
610
      if boot_floppy:
611
        kvm_cmd.extend(['-boot', 'a'])
612
        options = '%s,boot=on' % options
613
      if_val = ',if=floppy'
614
      options = '%s%s' % (options, if_val)
615
      drive_val = 'file=%s%s' % (floppy_image, options)
616
      kvm_cmd.extend(['-drive', drive_val])
617

    
618
    kernel_path = hvp[constants.HV_KERNEL_PATH]
619
    if kernel_path:
620
      kvm_cmd.extend(['-kernel', kernel_path])
621
      initrd_path = hvp[constants.HV_INITRD_PATH]
622
      if initrd_path:
623
        kvm_cmd.extend(['-initrd', initrd_path])
624
      root_append = ['root=%s' % hvp[constants.HV_ROOT_PATH],
625
                     hvp[constants.HV_KERNEL_ARGS]]
626
      if hvp[constants.HV_SERIAL_CONSOLE]:
627
        root_append.append('console=ttyS0,38400')
628
      kvm_cmd.extend(['-append', ' '.join(root_append)])
629

    
630
    mem_path = hvp[constants.HV_MEM_PATH]
631
    if mem_path:
632
      kvm_cmd.extend(["-mem-path", mem_path, "-mem-prealloc"])
633

    
634
    mouse_type = hvp[constants.HV_USB_MOUSE]
635
    vnc_bind_address = hvp[constants.HV_VNC_BIND_ADDRESS]
636

    
637
    if mouse_type:
638
      kvm_cmd.extend(['-usb'])
639
      kvm_cmd.extend(['-usbdevice', mouse_type])
640
    elif vnc_bind_address:
641
      kvm_cmd.extend(['-usbdevice', constants.HT_MOUSE_TABLET])
642

    
643
    if vnc_bind_address:
644
      if netutils.IP4Address.IsValid(vnc_bind_address):
645
        if instance.network_port > constants.VNC_BASE_PORT:
646
          display = instance.network_port - constants.VNC_BASE_PORT
647
          if vnc_bind_address == constants.IP4_ADDRESS_ANY:
648
            vnc_arg = ':%d' % (display)
649
          else:
650
            vnc_arg = '%s:%d' % (vnc_bind_address, display)
651
        else:
652
          logging.error("Network port is not a valid VNC display (%d < %d)."
653
                        " Not starting VNC", instance.network_port,
654
                        constants.VNC_BASE_PORT)
655
          vnc_arg = 'none'
656

    
657
        # Only allow tls and other option when not binding to a file, for now.
658
        # kvm/qemu gets confused otherwise about the filename to use.
659
        vnc_append = ''
660
        if hvp[constants.HV_VNC_TLS]:
661
          vnc_append = '%s,tls' % vnc_append
662
          if hvp[constants.HV_VNC_X509_VERIFY]:
663
            vnc_append = '%s,x509verify=%s' % (vnc_append,
664
                                               hvp[constants.HV_VNC_X509])
665
          elif hvp[constants.HV_VNC_X509]:
666
            vnc_append = '%s,x509=%s' % (vnc_append,
667
                                         hvp[constants.HV_VNC_X509])
668
        if hvp[constants.HV_VNC_PASSWORD_FILE]:
669
          vnc_append = '%s,password' % vnc_append
670

    
671
        vnc_arg = '%s%s' % (vnc_arg, vnc_append)
672

    
673
      else:
674
        vnc_arg = 'unix:%s/%s.vnc' % (vnc_bind_address, instance.name)
675

    
676
      kvm_cmd.extend(['-vnc', vnc_arg])
677
    else:
678
      kvm_cmd.extend(['-nographic'])
679

    
680
    monitor_dev = ("unix:%s,server,nowait" %
681
                   self._InstanceMonitor(instance.name))
682
    kvm_cmd.extend(['-monitor', monitor_dev])
683
    if hvp[constants.HV_SERIAL_CONSOLE]:
684
      serial_dev = ('unix:%s,server,nowait' %
685
                    self._InstanceSerial(instance.name))
686
      kvm_cmd.extend(['-serial', serial_dev])
687
    else:
688
      kvm_cmd.extend(['-serial', 'none'])
689

    
690
    if hvp[constants.HV_USE_LOCALTIME]:
691
      kvm_cmd.extend(['-localtime'])
692

    
693
    if hvp[constants.HV_KVM_USE_CHROOT]:
694
      kvm_cmd.extend(['-chroot', self._InstanceChrootDir(instance.name)])
695

    
696
    # Save the current instance nics, but defer their expansion as parameters,
697
    # as we'll need to generate executable temp files for them.
698
    kvm_nics = instance.nics
699
    hvparams = hvp
700

    
701
    return (kvm_cmd, kvm_nics, hvparams)
702

    
703
  def _WriteKVMRuntime(self, instance_name, data):
704
    """Write an instance's KVM runtime
705

706
    """
707
    try:
708
      utils.WriteFile(self._InstanceKVMRuntime(instance_name),
709
                      data=data)
710
    except EnvironmentError, err:
711
      raise errors.HypervisorError("Failed to save KVM runtime file: %s" % err)
712

    
713
  def _ReadKVMRuntime(self, instance_name):
714
    """Read an instance's KVM runtime
715

716
    """
717
    try:
718
      file_content = utils.ReadFile(self._InstanceKVMRuntime(instance_name))
719
    except EnvironmentError, err:
720
      raise errors.HypervisorError("Failed to load KVM runtime file: %s" % err)
721
    return file_content
722

    
723
  def _SaveKVMRuntime(self, instance, kvm_runtime):
724
    """Save an instance's KVM runtime
725

726
    """
727
    kvm_cmd, kvm_nics, hvparams = kvm_runtime
728
    serialized_nics = [nic.ToDict() for nic in kvm_nics]
729
    serialized_form = serializer.Dump((kvm_cmd, serialized_nics, hvparams))
730
    self._WriteKVMRuntime(instance.name, serialized_form)
731

    
732
  def _LoadKVMRuntime(self, instance, serialized_runtime=None):
733
    """Load an instance's KVM runtime
734

735
    """
736
    if not serialized_runtime:
737
      serialized_runtime = self._ReadKVMRuntime(instance.name)
738
    loaded_runtime = serializer.Load(serialized_runtime)
739
    kvm_cmd, serialized_nics, hvparams = loaded_runtime
740
    kvm_nics = [objects.NIC.FromDict(snic) for snic in serialized_nics]
741
    return (kvm_cmd, kvm_nics, hvparams)
742

    
743
  def _RunKVMCmd(self, name, kvm_cmd, tap_fds=None):
744
    """Run the KVM cmd and check for errors
745

746
    @type name: string
747
    @param name: instance name
748
    @type kvm_cmd: list of strings
749
    @param kvm_cmd: runcmd input for kvm
750
    @type tap_fds: list of int
751
    @param tap_fds: fds of tap devices opened by Ganeti
752

753
    """
754
    try:
755
      result = utils.RunCmd(kvm_cmd, noclose_fds=tap_fds)
756
    finally:
757
      for fd in tap_fds:
758
        utils_wrapper.CloseFdNoError(fd)
759

    
760
    if result.failed:
761
      raise errors.HypervisorError("Failed to start instance %s: %s (%s)" %
762
                                   (name, result.fail_reason, result.output))
763
    if not self._InstancePidAlive(name)[2]:
764
      raise errors.HypervisorError("Failed to start instance %s" % name)
765

    
766
  def _ExecuteKVMRuntime(self, instance, kvm_runtime, incoming=None):
767
    """Execute a KVM cmd, after completing it with some last minute data
768

769
    @type incoming: tuple of strings
770
    @param incoming: (target_host_ip, port)
771

772
    """
773
    # Small _ExecuteKVMRuntime hv parameters programming howto:
774
    #  - conf_hvp contains the parameters as configured on ganeti. they might
775
    #    have changed since the instance started; only use them if the change
776
    #    won't affect the inside of the instance (which hasn't been rebooted).
777
    #  - up_hvp contains the parameters as they were when the instance was
778
    #    started, plus any new parameter which has been added between ganeti
779
    #    versions: it is paramount that those default to a value which won't
780
    #    affect the inside of the instance as well.
781
    conf_hvp = instance.hvparams
782
    name = instance.name
783
    self._CheckDown(name)
784

    
785
    temp_files = []
786

    
787
    kvm_cmd, kvm_nics, up_hvp = kvm_runtime
788
    up_hvp = objects.FillDict(conf_hvp, up_hvp)
789

    
790
    kvm_version = self._GetKVMVersion()
791
    if kvm_version:
792
      _, v_major, v_min, _ = kvm_version
793
    else:
794
      raise errors.HypervisorError("Unable to get KVM version")
795

    
796
    # We know it's safe to run as a different user upon migration, so we'll use
797
    # the latest conf, from conf_hvp.
798
    security_model = conf_hvp[constants.HV_SECURITY_MODEL]
799
    if security_model == constants.HT_SM_USER:
800
      kvm_cmd.extend(["-runas", conf_hvp[constants.HV_SECURITY_DOMAIN]])
801

    
802
    # We have reasons to believe changing something like the nic driver/type
803
    # upon migration won't exactly fly with the instance kernel, so for nic
804
    # related parameters we'll use up_hvp
805
    tapfds = []
806
    taps = []
807
    if not kvm_nics:
808
      kvm_cmd.extend(["-net", "none"])
809
    else:
810
      vnet_hdr = False
811
      tap_extra = ""
812
      nic_type = up_hvp[constants.HV_NIC_TYPE]
813
      if nic_type == constants.HT_NIC_PARAVIRTUAL:
814
        # From version 0.12.0, kvm uses a new sintax for network configuration.
815
        if (v_major, v_min) >= (0, 12):
816
          nic_model = "virtio-net-pci"
817
          vnet_hdr = True
818
        else:
819
          nic_model = "virtio"
820

    
821
        if up_hvp[constants.HV_VHOST_NET]:
822
          # vhost_net is only available from version 0.13.0 or newer
823
          if (v_major, v_min) >= (0, 13):
824
            tap_extra = ",vhost=on"
825
          else:
826
            raise errors.HypervisorError("vhost_net is configured"
827
                                        " but it is not available")
828
      else:
829
        nic_model = nic_type
830

    
831
      for nic_seq, nic in enumerate(kvm_nics):
832
        tapname, tapfd = _OpenTap(vnet_hdr)
833
        tapfds.append(tapfd)
834
        taps.append(tapname)
835
        if (v_major, v_min) >= (0, 12):
836
          nic_val = "%s,mac=%s,netdev=netdev%s" % (nic_model, nic.mac, nic_seq)
837
          tap_val = "type=tap,id=netdev%s,fd=%d%s" % (nic_seq, tapfd, tap_extra)
838
          kvm_cmd.extend(["-netdev", tap_val, "-device", nic_val])
839
        else:
840
          nic_val = "nic,vlan=%s,macaddr=%s,model=%s" % (nic_seq,
841
                                                         nic.mac, nic_model)
842
          tap_val = "tap,vlan=%s,fd=%d" % (nic_seq, tapfd)
843
          kvm_cmd.extend(["-net", tap_val, "-net", nic_val])
844

    
845
    if incoming:
846
      target, port = incoming
847
      kvm_cmd.extend(['-incoming', 'tcp:%s:%s' % (target, port)])
848

    
849
    # Changing the vnc password doesn't bother the guest that much. At most it
850
    # will surprise people who connect to it. Whether positively or negatively
851
    # it's debatable.
852
    vnc_pwd_file = conf_hvp[constants.HV_VNC_PASSWORD_FILE]
853
    vnc_pwd = None
854
    if vnc_pwd_file:
855
      try:
856
        vnc_pwd = utils.ReadOneLineFile(vnc_pwd_file, strict=True)
857
      except EnvironmentError, err:
858
        raise errors.HypervisorError("Failed to open VNC password file %s: %s"
859
                                     % (vnc_pwd_file, err))
860

    
861
    if conf_hvp[constants.HV_KVM_USE_CHROOT]:
862
      utils.EnsureDirs([(self._InstanceChrootDir(name),
863
                         constants.SECURE_DIR_MODE)])
864

    
865
    if not incoming:
866
      # Configure the network now for starting instances, during
867
      # FinalizeMigration for incoming instances
868
      for nic_seq, nic in enumerate(kvm_nics):
869
        self._ConfigureNIC(instance, nic_seq, nic, taps[nic_seq])
870

    
871
    if security_model == constants.HT_SM_POOL:
872
      ss = ssconf.SimpleStore()
873
      uid_pool = uidpool.ParseUidPool(ss.GetUidPool(), separator="\n")
874
      all_uids = set(uidpool.ExpandUidPool(uid_pool))
875
      uid = uidpool.RequestUnusedUid(all_uids)
876
      try:
877
        username = pwd.getpwuid(uid.GetUid()).pw_name
878
        kvm_cmd.extend(["-runas", username])
879
        self._RunKVMCmd(name, kvm_cmd, tapfds)
880
      except:
881
        uidpool.ReleaseUid(uid)
882
        raise
883
      else:
884
        uid.Unlock()
885
        utils.WriteFile(self._InstanceUidFile(name), data=str(uid))
886
    else:
887
      self._RunKVMCmd(name, kvm_cmd, tapfds)
888

    
889
    utils.EnsureDirs([(self._InstanceNICDir(instance.name),
890
                     constants.RUN_DIRS_MODE)])
891
    for nic_seq, tap in enumerate(taps):
892
      utils.WriteFile(self._InstanceNICFile(instance.name, nic_seq),
893
                      data=tap)
894

    
895
    if vnc_pwd:
896
      change_cmd = 'change vnc password %s' % vnc_pwd
897
      self._CallMonitorCommand(instance.name, change_cmd)
898

    
899
    for filename in temp_files:
900
      utils.RemoveFile(filename)
901

    
902
  def StartInstance(self, instance, block_devices):
903
    """Start an instance.
904

905
    """
906
    self._CheckDown(instance.name)
907
    kvm_runtime = self._GenerateKVMRuntime(instance, block_devices)
908
    self._SaveKVMRuntime(instance, kvm_runtime)
909
    self._ExecuteKVMRuntime(instance, kvm_runtime)
910

    
911
  def _CallMonitorCommand(self, instance_name, command):
912
    """Invoke a command on the instance monitor.
913

914
    """
915
    socat = ("echo %s | %s STDIO UNIX-CONNECT:%s" %
916
             (utils.ShellQuote(command),
917
              constants.SOCAT_PATH,
918
              utils.ShellQuote(self._InstanceMonitor(instance_name))))
919
    result = utils.RunCmd(socat)
920
    if result.failed:
921
      msg = ("Failed to send command '%s' to instance %s."
922
             " output: %s, error: %s, fail_reason: %s" %
923
             (command, instance_name,
924
              result.stdout, result.stderr, result.fail_reason))
925
      raise errors.HypervisorError(msg)
926

    
927
    return result
928

    
929
  @classmethod
930
  def _GetKVMVersion(cls):
931
    """Return the installed KVM version
932

933
    @return: (version, v_maj, v_min, v_rev), or None
934

935
    """
936
    result = utils.RunCmd([constants.KVM_PATH, "--help"])
937
    if result.failed:
938
      return None
939
    match = cls._VERSION_RE.search(result.output.splitlines()[0])
940
    if not match:
941
      return None
942

    
943
    return (match.group(0), int(match.group(1)), int(match.group(2)),
944
            int(match.group(3)))
945

    
946
  def StopInstance(self, instance, force=False, retry=False, name=None):
947
    """Stop an instance.
948

949
    """
950
    if name is not None and not force:
951
      raise errors.HypervisorError("Cannot shutdown cleanly by name only")
952
    if name is None:
953
      name = instance.name
954
      acpi = instance.hvparams[constants.HV_ACPI]
955
    else:
956
      acpi = False
957
    _, pid, alive = self._InstancePidAlive(name)
958
    if pid > 0 and alive:
959
      if force or not acpi:
960
        utils.KillProcess(pid)
961
      else:
962
        self._CallMonitorCommand(name, 'system_powerdown')
963

    
964
  def CleanupInstance(self, instance_name):
965
    """Cleanup after a stopped instance
966

967
    """
968
    pidfile, pid, alive = self._InstancePidAlive(instance_name)
969
    if pid > 0 and alive:
970
      raise errors.HypervisorError("Cannot cleanup a live instance")
971
    self._RemoveInstanceRuntimeFiles(pidfile, instance_name)
972

    
973
  def RebootInstance(self, instance):
974
    """Reboot an instance.
975

976
    """
977
    # For some reason if we do a 'send-key ctrl-alt-delete' to the control
978
    # socket the instance will stop, but now power up again. So we'll resort
979
    # to shutdown and restart.
980
    _, _, alive = self._InstancePidAlive(instance.name)
981
    if not alive:
982
      raise errors.HypervisorError("Failed to reboot instance %s:"
983
                                   " not running" % instance.name)
984
    # StopInstance will delete the saved KVM runtime so:
985
    # ...first load it...
986
    kvm_runtime = self._LoadKVMRuntime(instance)
987
    # ...now we can safely call StopInstance...
988
    if not self.StopInstance(instance):
989
      self.StopInstance(instance, force=True)
990
    # ...and finally we can save it again, and execute it...
991
    self._SaveKVMRuntime(instance, kvm_runtime)
992
    self._ExecuteKVMRuntime(instance, kvm_runtime)
993

    
994
  def MigrationInfo(self, instance):
995
    """Get instance information to perform a migration.
996

997
    @type instance: L{objects.Instance}
998
    @param instance: instance to be migrated
999
    @rtype: string
1000
    @return: content of the KVM runtime file
1001

1002
    """
1003
    return self._ReadKVMRuntime(instance.name)
1004

    
1005
  def AcceptInstance(self, instance, info, target):
1006
    """Prepare to accept an instance.
1007

1008
    @type instance: L{objects.Instance}
1009
    @param instance: instance to be accepted
1010
    @type info: string
1011
    @param info: content of the KVM runtime file on the source node
1012
    @type target: string
1013
    @param target: target host (usually ip), on this node
1014

1015
    """
1016
    kvm_runtime = self._LoadKVMRuntime(instance, serialized_runtime=info)
1017
    incoming_address = (target, instance.hvparams[constants.HV_MIGRATION_PORT])
1018
    self._ExecuteKVMRuntime(instance, kvm_runtime, incoming=incoming_address)
1019

    
1020
  def FinalizeMigration(self, instance, info, success):
1021
    """Finalize an instance migration.
1022

1023
    Stop the incoming mode KVM.
1024

1025
    @type instance: L{objects.Instance}
1026
    @param instance: instance whose migration is being finalized
1027

1028
    """
1029
    if success:
1030
      kvm_runtime = self._LoadKVMRuntime(instance, serialized_runtime=info)
1031
      kvm_nics = kvm_runtime[1]
1032

    
1033
      for nic_seq, nic in enumerate(kvm_nics):
1034
        try:
1035
          tap = utils.ReadFile(self._InstanceNICFile(instance.name, nic_seq))
1036
        except EnvironmentError, err:
1037
          logging.warning("Failed to find host interface for %s NIC #%d: %s",
1038
                          instance.name, nic_seq, str(err))
1039
          continue
1040
        try:
1041
          self._ConfigureNIC(instance, nic_seq, nic, tap)
1042
        except errors.HypervisorError, err:
1043
          logging.warning(str(err))
1044

    
1045
      self._WriteKVMRuntime(instance.name, info)
1046
    else:
1047
      self.StopInstance(instance, force=True)
1048

    
1049
  def MigrateInstance(self, instance, target, live):
1050
    """Migrate an instance to a target node.
1051

1052
    The migration will not be attempted if the instance is not
1053
    currently running.
1054

1055
    @type instance: L{objects.Instance}
1056
    @param instance: the instance to be migrated
1057
    @type target: string
1058
    @param target: ip address of the target node
1059
    @type live: boolean
1060
    @param live: perform a live migration
1061

1062
    """
1063
    instance_name = instance.name
1064
    port = instance.hvparams[constants.HV_MIGRATION_PORT]
1065
    pidfile, pid, alive = self._InstancePidAlive(instance_name)
1066
    if not alive:
1067
      raise errors.HypervisorError("Instance not running, cannot migrate")
1068

    
1069
    if not live:
1070
      self._CallMonitorCommand(instance_name, 'stop')
1071

    
1072
    migrate_command = ('migrate_set_speed %dm' %
1073
        instance.hvparams[constants.HV_MIGRATION_BANDWIDTH])
1074
    self._CallMonitorCommand(instance_name, migrate_command)
1075

    
1076
    migrate_command = ('migrate_set_downtime %dms' %
1077
        instance.hvparams[constants.HV_MIGRATION_DOWNTIME])
1078
    self._CallMonitorCommand(instance_name, migrate_command)
1079

    
1080
    migrate_command = 'migrate -d tcp:%s:%s' % (target, port)
1081
    self._CallMonitorCommand(instance_name, migrate_command)
1082

    
1083
    info_command = 'info migrate'
1084
    done = False
1085
    broken_answers = 0
1086
    while not done:
1087
      result = self._CallMonitorCommand(instance_name, info_command)
1088
      match = self._MIGRATION_STATUS_RE.search(result.stdout)
1089
      if not match:
1090
        broken_answers += 1
1091
        if not result.stdout:
1092
          logging.info("KVM: empty 'info migrate' result")
1093
        else:
1094
          logging.warning("KVM: unknown 'info migrate' result: %s",
1095
                          result.stdout)
1096
        time.sleep(self._MIGRATION_INFO_RETRY_DELAY)
1097
      else:
1098
        status = match.group(1)
1099
        if status == 'completed':
1100
          done = True
1101
        elif status == 'active':
1102
          # reset the broken answers count
1103
          broken_answers = 0
1104
          time.sleep(self._MIGRATION_INFO_RETRY_DELAY)
1105
        elif status == 'failed' or status == 'cancelled':
1106
          if not live:
1107
            self._CallMonitorCommand(instance_name, 'cont')
1108
          raise errors.HypervisorError("Migration %s at the kvm level" %
1109
                                       status)
1110
        else:
1111
          logging.warning("KVM: unknown migration status '%s'", status)
1112
          broken_answers += 1
1113
          time.sleep(self._MIGRATION_INFO_RETRY_DELAY)
1114
      if broken_answers >= self._MIGRATION_INFO_MAX_BAD_ANSWERS:
1115
        raise errors.HypervisorError("Too many 'info migrate' broken answers")
1116

    
1117
    utils.KillProcess(pid)
1118
    self._RemoveInstanceRuntimeFiles(pidfile, instance_name)
1119

    
1120
  def GetNodeInfo(self):
1121
    """Return information about the node.
1122

1123
    This is just a wrapper over the base GetLinuxNodeInfo method.
1124

1125
    @return: a dict with the following keys (values in MiB):
1126
          - memory_total: the total memory size on the node
1127
          - memory_free: the available memory on the node for instances
1128
          - memory_dom0: the memory used by the node itself, if available
1129

1130
    """
1131
    return self.GetLinuxNodeInfo()
1132

    
1133
  @classmethod
1134
  def GetInstanceConsole(cls, instance, hvparams, beparams):
1135
    """Return a command for connecting to the console of an instance.
1136

1137
    """
1138
    if hvparams[constants.HV_SERIAL_CONSOLE]:
1139
      cmd = [constants.SOCAT_PATH,
1140
             "STDIO,%s" % cls._SocatUnixConsoleParams(),
1141
             "UNIX-CONNECT:%s" % cls._InstanceSerial(instance.name)]
1142
      return objects.InstanceConsole(instance=instance.name,
1143
                                     kind=constants.CONS_SSH,
1144
                                     host=instance.primary_node,
1145
                                     user=constants.GANETI_RUNAS,
1146
                                     command=cmd)
1147

    
1148
    vnc_bind_address = hvparams[constants.HV_VNC_BIND_ADDRESS]
1149
    if vnc_bind_address and instance.network_port > constants.VNC_BASE_PORT:
1150
      display = instance.network_port - constants.VNC_BASE_PORT
1151
      return objects.InstanceConsole(instance=instance.name,
1152
                                     kind=constants.CONS_VNC,
1153
                                     host=vnc_bind_address,
1154
                                     port=instance.network_port,
1155
                                     display=display)
1156

    
1157
    return objects.InstanceConsole(instance=instance.name,
1158
                                   kind=constants.CONS_MESSAGE,
1159
                                   message=("No serial shell for instance %s" %
1160
                                            instance.name))
1161

    
1162
  def Verify(self):
1163
    """Verify the hypervisor.
1164

1165
    Check that the binary exists.
1166

1167
    """
1168
    if not os.path.exists(constants.KVM_PATH):
1169
      return "The kvm binary ('%s') does not exist." % constants.KVM_PATH
1170
    if not os.path.exists(constants.SOCAT_PATH):
1171
      return "The socat binary ('%s') does not exist." % constants.SOCAT_PATH
1172

    
1173
  @classmethod
1174
  def CheckParameterSyntax(cls, hvparams):
1175
    """Check the given parameters for validity.
1176

1177
    @type hvparams:  dict
1178
    @param hvparams: dictionary with parameter names/value
1179
    @raise errors.HypervisorError: when a parameter is not valid
1180

1181
    """
1182
    super(KVMHypervisor, cls).CheckParameterSyntax(hvparams)
1183

    
1184
    kernel_path = hvparams[constants.HV_KERNEL_PATH]
1185
    if kernel_path:
1186
      if not hvparams[constants.HV_ROOT_PATH]:
1187
        raise errors.HypervisorError("Need a root partition for the instance,"
1188
                                     " if a kernel is defined")
1189

    
1190
    if (hvparams[constants.HV_VNC_X509_VERIFY] and
1191
        not hvparams[constants.HV_VNC_X509]):
1192
      raise errors.HypervisorError("%s must be defined, if %s is" %
1193
                                   (constants.HV_VNC_X509,
1194
                                    constants.HV_VNC_X509_VERIFY))
1195

    
1196
    boot_order = hvparams[constants.HV_BOOT_ORDER]
1197
    if (boot_order == constants.HT_BO_CDROM and
1198
        not hvparams[constants.HV_CDROM_IMAGE_PATH]):
1199
      raise errors.HypervisorError("Cannot boot from cdrom without an"
1200
                                   " ISO path")
1201

    
1202
    security_model = hvparams[constants.HV_SECURITY_MODEL]
1203
    if security_model == constants.HT_SM_USER:
1204
      if not hvparams[constants.HV_SECURITY_DOMAIN]:
1205
        raise errors.HypervisorError("A security domain (user to run kvm as)"
1206
                                     " must be specified")
1207
    elif (security_model == constants.HT_SM_NONE or
1208
          security_model == constants.HT_SM_POOL):
1209
      if hvparams[constants.HV_SECURITY_DOMAIN]:
1210
        raise errors.HypervisorError("Cannot have a security domain when the"
1211
                                     " security model is 'none' or 'pool'")
1212

    
1213
  @classmethod
1214
  def ValidateParameters(cls, hvparams):
1215
    """Check the given parameters for validity.
1216

1217
    @type hvparams:  dict
1218
    @param hvparams: dictionary with parameter names/value
1219
    @raise errors.HypervisorError: when a parameter is not valid
1220

1221
    """
1222
    super(KVMHypervisor, cls).ValidateParameters(hvparams)
1223

    
1224
    security_model = hvparams[constants.HV_SECURITY_MODEL]
1225
    if security_model == constants.HT_SM_USER:
1226
      username = hvparams[constants.HV_SECURITY_DOMAIN]
1227
      try:
1228
        pwd.getpwnam(username)
1229
      except KeyError:
1230
        raise errors.HypervisorError("Unknown security domain user %s"
1231
                                     % username)
1232

    
1233
  @classmethod
1234
  def PowercycleNode(cls):
1235
    """KVM powercycle, just a wrapper over Linux powercycle.
1236

1237
    """
1238
    cls.LinuxPowercycle()