Add the ‘gnt-cluster verify-disks’ command
This patch adds the OpVerifyDisks handling in mcpu.py and theverify-disks command in the gnt-cluster script, which for every instancecomputed by LUVerifyDisks submits a new OpActivateInstanceDisks request.
Reviewed-by: imsnah
Various code style fixes for strings.
- When line wrapping is needed, move spaces to the next line.- Remove embedded line breaks from error messages.
Reviewed-by: schreiberal
Replace disk template drbd8 with drbd where missing.
Reviewed-by: iustinp
Correct the -s parameter in gnt-node output
This fixed the previous commit (-s => -s ip).
Reviewed-by: ultrotter
Add the -s option in the output of 'gnt-node'
Since on dual-homed clusters one always needs to add '-s' to thegnt-node add command, make this appear in the output of 'gnt-node' (whenrun without arguments).
Fix --node option for “gnt-backup list”.
Change --nodes to --node
The --nodes option in gnt-backup really accepts only one node at a time.Change it to --node, for added clarity and consistency with a similaroption in gnt-cluster. This patch also updates the relevant man page.
Reviewed-By: iustinp
Enhance secondary node replace for drbd8
This (big) patch does two things: - add "local disk status" to the block device checks (BlockDevice.GetSyncStatus and the rpc calls that call this function, and therefore cmdlib._CheckDiskConsistency) - improve the drbd8 secondary replace operation using the above...
Remove --secondary-node option.
Replace --secondary-node option with an optional parameter for --node.
Implement degraded status for logical volumes
Logical volumes can be 'degraded' in a similar way to mirrored devices,when their underlying storage has gone away (i.e. after a physical diskfailure and 'vgreduce --removemissing'). If we can detect this, we can...