Fix typo.
Reviewed-by: iustin
Disable hashing of the ssh keys.
In case we use StrictHostKeyChecking=ask, also add HashKnownHosts=no so thatdebugging is easier. The nodes to which we are connecting are anyway visible in/etc/ssh/ssh_known_hosts.
Add support for listing instance disk sizes.
Reviewed-by: imsnah
A CheckPrereq method had one unconverted "return 1" statement. Change it to theappropriate raise.
Change cli.OutputTable to cli.GenerateTable
Since the table generation might be useful elsewhere, let's change it toreturn the data instead of directly printing it.
Its callers have also been updated.
Some small fixes.
It fixes the main Makefile.am to create $localstatedir/{lib,log}/ganeti.It fixes the testing Makefile.am after the rename fake_config.py ->mocks.py. It strips the output of "ip link show" to have a nicer outputif the master netdev does not exist.
Style changes for pep-8 and python-3000 compliance.
This changes the raising of exceptions from: raise Exception, valueto raise Exception(value)
as the first form will be removed in python-3000 and the second form ispreferred now.
The changes also involve a few cases of changing from raising standard...
Implement tag support for cluster, nodes and instances.
This is only the backend part, from the command line the tags can't beread/modified yet.
Don't bail out if node isn't there on “gnt-node volumes”.
Reviewed-by: iustinp
Prepare for the tags implementation: - add an Update method on the ConfigWriter class; - make the AddInstance method not log disks for diskless types (helps with testing) - implement limited testing for the ConfigWriter with focus on the new Update method
Re-stat the config file when we write it so that the next _OpenConfig()won't reread it if not modified by someone else.
Add instance name to LVM volume as a tag.
Implement a standard way of getting the cluster object from theconfiguration.
Change logival volume names to not be based on the instance's name, butinstead use an UUID prefix and a suffix denoting the disk iv_name(sda/sdb) and possibly it's type (data/meta).
Put synchronization speed into constant.
Put default bridge into constant.
Add configuration upgrade utility.
Implement setitem for ConfigObject to add container protocol compatibility.
Fix issues reported by pylint.
Unify environment variables for instance related hooks.
Check for instances on “gnt-cluster destroy”.
- Implement “gnt-instance reinstall --os-type=…”- Add the command to gnt-instance.sgml
Fix the "gnt-cluster getmaster" command by making the LuQueryClusterInforunnable on non-master nodes (and remove the list of instances and nodesreturned by it, that information can be retrieved by other opcodes).
Also, remove the node/instance list from "gnt-cluster info" as it...
Move the cluster name from ConfigWriter to SimpleStore.
Reason: if left ConfigWriter, nodes don't know to which cluster they belong.This will bite us later when we'll revisit node join operation.
Cons: we lose the cluster name from the config file, which means a...
- Move --force option to cli.py- Implement “gnt-instance reinstall”- Fix two typos
Don't pass master_node
Comment formatting updates.
The master_node is no longer stored in the config file (but in sstore)and all users have been converted, let's remove it from the slots of thecluster object.
Also let's move the tcpudp_port_pool to the cluster object.
Get ports from configuration if there are some.
It seems the _CheckNodesDirs function is no longer used. Let's remove it.
Since the watcher can run on all nodes, let's get rid of the cron filehandling, as it can be static and outside of ganeti.
This also means we can get rid of a lot of infrastructure too: - the master/node config files checkers - one rpc function
Make the ganeti-watcher exit gracefully if it's not run on the master.
Add description, fix indentation.
Use generic function to output tables.
- Implement “gnt-node volumes”- Create all --output options using a constant- Put node checking code from opcodes into a single function- Do the same for output fields
Big change/cleanup in relation to the master startup: - move the master node name from the ConfigWriter to SimpleStore (all nodes need this, and it was the only thing pulled in from the ConfigWriter on nodes) - fix mcpu.py and the testing w.r.t. this change; for testing, rename...
Do the secondary check and subsequently allocate the drive on all availablelogival volumes. This lets you use more than one when none of them can supportyour full drive size.
Reviewed-By: iustinp
Fix a typo in an error message, and actually pass it its parameters.
Reviewed-By: imsnah
Output instance name in error message instead of object representation.
Fix calls to _GenerateMDDRBDBranch.
Check for memory size requirements before failing over an instance.
Implement space requirement checking before creating/importing an instance.
Initial commit.