Statistics
| Branch: | Tag: | Revision:

root / test / py / ganeti.rpc_unittest.py @ 6b06efa7

History | View | Annotate | Download (33.8 kB)

# Date Author Comment
baaa2ece 01/28/2014 03:17 pm Klaus Aehlig

Merge branch 'stable-2.10' into stable-2.11

  • stable-2.10
    Enable network tags in Haskell code
    Haskell style: explicit errors, visible in the type
    Clarify spacing in record syntax
    Improve the point-free section of the style guide
    Add code style document to documentation...
410945f1 01/27/2014 05:36 pm Klaus Aehlig

Merge branch 'stable-2.9' into stable-2.10

  • stable-2.9
    Revision bump for 2.9.3
    Schedule 2.9.3 release
    Document fix of issue 691 in NEWS
    NEWS: fix typo in 2.8.4 release
    Fix 'hvparams' of '_InstanceStartupMemory' on hypervisors
    Add missing option to gnt-instance documentation...
52a988f2 12/20/2013 11:34 am Michele Tartara

Fix testEncodeInstance test input

The input of the testEncodeInstance test was not adherent to the actual format
of the Ganeti configuration file: kvm has no HV_BLOCKDEV_PREFIX, and "hvparams"
inside an instance should only contain the values of the hypervisor parameters,...

4869595d 12/17/2013 10:11 pm Petr Pudlak

Add a Python directory for RPC code to keep it at one place

Move rpc.py to rpc/node.py and modify imports in existing code.

Signed-off-by: Petr Pudlak <>
Reviewed-by: Helga Velroyen <>

6c00b2c7 10/15/2013 02:13 pm Helga Velroyen

Streamlining handling of spindles and default templates

This rather lenghy patch comprises a couple of refactorings
to achieve the following goals:
- 'gnt-node info' should only report space information about
spindles, when exclusive storage is enabled on the node...

4d1429e4 10/15/2013 02:13 pm Helga Velroyen

Rename entities of unit test for MakeLegacyNodeInfo

This is a small preparation step for the next patch.
It just renames the key/value constants for the unit
test of MakeLegacyNodeInfo, because they were rather
undescriptive and thus made changes to the test cumbersome....

3d835d1b 09/24/2013 09:17 am Thomas Thrainer

Fix tests related to the physical_id field

Remove all references to the physical_id field of disk objects in tests.

Signed-off-by: Thomas Thrainer <>
Reviewed-by: Jose A. Lopes <>

cd3b4ff4 08/28/2013 06:19 pm Helga Velroyen

Replace LD_* constants with DT_* constants

LD_* constants are basically like DT_* constants, except
for that both file and shared file were mapped to file.
In order to not having to maintain three slightly different
sets of disk-related constants (DT, LD and ST), we merge...

20faaa74 07/03/2013 12:41 pm Helga Velroyen

Improve handling of storage info

This patch improves the processing of storage information
as result of the 'node_info' call in the following way:
- It removes the override for LVM storage. This was needed
in MakeLegacyNode info to be compatible to the...

b844311b 06/27/2013 12:05 pm Helga Velroyen

rpc.py: override default storage type in node info

This patch changes the semantics of dealing with the result
of the RPC call "node_info" when converting them into a
LegacyNodeInfo. A legacy node info, can only hold storage
information about one storage type, which so far was always...

32389d91 06/14/2013 02:43 pm Helga Velroyen

Refactor NodeInfo RPC regarding storage reporting

The NodeInfo RPC call is refactored to handle now more than
just storage reporting for volume groups.

Since NodeInfo now returns storage space information not
necessarily for volume groups, but also for other storage...

1c3231aa 06/13/2013 12:32 pm Thomas Thrainer

Index nodes by their UUID

No longer index nodes by their name but by their UUID in the cluster
config. This change changes large parts of the code, as the following
adjustments were necessary: * Change the index key to UUID in the configuration and the
ConfigWriter, including all methods....

06fb92cf 06/07/2013 04:10 pm Bernardo Dal Seno

Export node spindles

Node spindles (queried live) are exported through the LUXI, RAPI, and
iallocator interfaces.

Signed-off-by: Bernardo Dal Seno <>
Reviewed-by: Klaus Aehlig <>

91c17910 03/04/2013 12:35 pm Iustin Pop

Allow rpc.MakeLegacyNodeInfo to parse non-LVM results

'MakeLegacyNodeInfo' is not the best place for this, but we'd have to
duplicate it if we wanted a LVM-less version, so the easiest is to add
an optional parameter that allows it to accept/skip LVM-less results....

90066780 12/27/2012 03:34 pm Iustin Pop

Move python test files to test/py

This is the first step of the test files reorganisation: moving test/*
(except test/data) to new directory test/py/.

Signed-off-by: Iustin Pop <>
Reviewed-by: Guido Trotter <>