Statistics
| Branch: | Tag: | Revision:

root / lib / cmdlib.py @ c5cc3403

History | View | Annotate | Download (145.8 kB)

# Date Author Comment
5f83e263 03/31/2008 05:39 pm Iustin Pop

Change the 'gnt-cluster command' execution order

This patch makes the command execute last on the master (if the master
is selected). The order for the other nodes is unchanged.

The patch also updates the man page with some explanations and an
example.
...

7767bbf5 03/31/2008 03:04 pm Manuel Franceschini

parms->params Refactoring

- Substitute all occurences of name 'parms' with 'params'
- Small codestyle fix

Reviewed-by: ultrotter

efa14262 03/31/2008 01:59 pm Manuel Franceschini

Skip HasValidVG when --no-lvm-storage on cluster init

This patch does two things:
- Remove "vg_name" from _OP_REQP due to the introduction of
--no-lvm-storage. Since vg_name option has as default now None and is
only set to the DEFAULT_VG if lvm_storage is enabled, this is needed...

8084f9f6 03/31/2008 01:59 pm Manuel Franceschini

Add LUSetClusterParams to cmdlib

Add LUSetClusterParams, which is the LU to modify cluster options.
This includes checks:
- not to disable lvm storage when it's already disabled
- not to enable lvm storage when it is already enabled
- not to disable lvm when lvm-based instances are present...

eedc99de 03/31/2008 01:57 pm Manuel Franceschini

Add lvm-storage check when creating instances

This adds a check to fail instance creation if lvm-storage is disabled
(cluster-wide). If lvm-storage is disabled (by initializing the cluster
with --no-lvm-storage) only instances with disk template in frozenset...

fe482621 03/30/2008 05:54 pm Iustin Pop

Change the order of config updates in some LUs

In the start and stop instance LUs, the configuration update is done
right at the end. This means that if, for example, the instance shutdown
succeeds, but the drive deactivation fails, the next run of the watcher...

0a80a26f 03/27/2008 04:39 pm Michael Hanselmann

Return first parameter of console command only once

Reviewed-by: iustinp

f9193417 03/25/2008 06:30 pm Iustin Pop

Remove the option to create md/drbd7 instances

This patch removes the options that allow to create local_raid1 or
remote_raid1 instances. It also modifies the documentation and removes
these disk templates from burnin and from qa.

Reviewed-by: imsnah

249069a1 03/25/2008 06:30 pm Iustin Pop

Remove the add/remove mirror operations

These two operations are related to md/drbd7 code (remote_raid1). Remove
them as part of the md/drbd7 removal.

Reviewed-by: imsnah

2872a949 03/20/2008 05:55 pm Manuel Franceschini

Modify cluster-init to create file-storage-dir

This patch adds three things:
- it normalizes the file storage directory path passed to gnt-cluster init
- if the file-storage-path doesn't exist on the master node, ganeti
tries to create it
- adds additional check if the passed file-storage-dir is not a directory...

871705db 03/19/2008 12:47 pm Manuel Franceschini

Add support for file_storage_dir to LUInitCluster

Author: manuel.franceschini
Reviewed-by: iustinp

f408b346 03/18/2008 03:04 pm Michael Hanselmann

Use new ssh.WriteKnownHostsFile function

This replaces very old code.

Reviewed-by: ultrotter

1ff08570 03/18/2008 03:03 pm Michael Hanselmann

Use new cluster alias in known_hosts file

Reviewed-by: ultrotter

b047857b 03/18/2008 03:03 pm Michael Hanselmann

Use new “tty” parameter on SshRunner.BuildCmd for “gnt-instance console”

Reviewed-by: ultrotter

c92b310a 03/18/2008 03:02 pm Michael Hanselmann

Move SSH functions into a class

This renames some functions and does some minor codestyle cleanup.

Reviewed-by: ultrotter

411f8ad0 03/11/2008 09:44 am Iustin Pop

Disable cluster init with a reachable IP

Make the cluster init fail if the IP to which the cluster name resolved
is already reachable by the master node. This is not a foolproof
solution, but it allows a cheap method of detecting simple mistakes.

It will also disallow using the master node name as cluster name (which...

b15d625f 03/11/2008 09:44 am Iustin Pop

Modify utils.TcpPing to make source address optional

This patch modifies TcpPing and its callers to make the source address
selection optional. Usually, the kernel will know better what
source address to use, just in some cases we want to enforce a given...

7c0d6283 03/05/2008 04:39 pm Michael Hanselmann

Codestyle fixes: adding a few empty lines

Reviewed-by: ultrotter

c9064964 02/29/2008 06:32 pm Iustin Pop

Fix master role stop on cluster destroy

Currently the cluster destroy doesn't remove the master role, which
means that the IP address of the cluster remains assigned to the master
node.

This patch fixes this and also a docstring in backend.StopMaster()....

488b540d 02/29/2008 02:32 pm Iustin Pop

Fix cluster rename operation

This one-liner fixes the cluster rename operation. As a side note, we
should have a QA test for this too.

Reviewed-by: imsnah

7bde3275 02/28/2008 01:20 pm Guido Trotter

Don't allow renaming to an existing instance

Even if the target instance is down or we are not checking for IP conflicts
changing an instance name to a new one which is already in the cluster is
doomed to fail, because in a lot of places (among which figures the mind of...

107711b0 02/27/2008 03:05 pm Michael Hanselmann

Use constants.ETC_HOSTS instead of string for /etc/hosts

Reviewed-by: iustinp

3517d9b9 02/25/2008 11:17 am Manuel Franceschini

This patch replaces some hardcoded strings with their corresponding constant in `_GenerateDiskTemplate()`.

Reviewed-by: iustinp

c99a3cc0 02/22/2008 06:12 pm Manuel Franceschini

Fixes small spell mistakes and comments

515207af 02/16/2008 03:06 pm Guido Trotter

Fix gnt-instance info i1 i2 ...

Due to an indentation error only the last instance queried got returned by
LUQueryInstanceData. Moving the append() call inside the for cycle to fix this
issue.

This is a one-liner targeted at 1.2.3

Reviewed-by: iustinp

ef756965 02/15/2008 11:53 am Iustin Pop

Further fixes for the 'export MAC in hooks' change

QA suite which tests gnt-instance modify has uncovered another issue related to
mac export.

Reviewed-by: imsnah

d8052456 02/14/2008 05:53 pm Iustin Pop

Modify the default output of gnt-instance list

This patch adds a new field available for selection in gnt-instance list
names "status" which represents the combined value of "admin_state" and
"oper_state". Since this is much easier to parse (e.g. gnt-instance list...

06009e27 02/05/2008 04:12 pm Iustin Pop

Add a test opcode that sleeps for a given duration

This can be used for testing purposes.

Reviewed-by: ultrotter,imsnah

fdbd668d 02/05/2008 03:33 pm Iustin Pop

Reduce the chance of DRBD errors with stale primaries

This patch is a first step in reducing the chance of causing DRBD
activation failures when the primary node has not-perfect data.

This issue is more seen with DRBD8, which has an 'outdate' state (in
which it can get more often). But it can (and before this patch, usually...

b08d5a87 02/04/2008 04:33 pm Iustin Pop

Fix some indendation issues

Reviewed-by: imsnah

c7b27e9e 02/04/2008 04:28 pm Iustin Pop

Fix incomplete mac address export to hooks

This patch completes the change introduced in r566 (trunk) and r568
(branch-1.2).

Reviewed-by: imsnah

53e4e875 01/31/2008 03:22 pm Guido Trotter

Give mac information to instance hooks

Currently just the bridge and ip address are passed. Add an environment
variable for the mac address.

Reviewed-by: iustinp

d6d415e8 01/28/2008 01:51 pm Iustin Pop

Add option for the number of VCPUs in instance listing

Reviewed-by: ultrotter

2bc22872 01/28/2008 11:03 am Iustin Pop

Fix "gnt-instance modify --initrd"

The new QA tests for instance modify uncovered a bug in the modify
initrd operation when setting the initrd to none.

Reviewed-by: imsnah

8d75db10 01/21/2008 12:12 am Iustin Pop

Fix checking of node free disk in CreateInstance

This patch does two things:
- checks that the result values from call_node_info are valid integer
values and aborts otherwise
- skips disk space computation for the DT_DISKLESS case

The most important point of the patch is the verification of results...

d4f16fd9 01/21/2008 12:12 am Iustin Pop

Abstract node memory checking into a separate function

The checking of a node's free memory (via rpc.call_node_info) is done in
both start instance an failover. This patch abstracts this call,
together with the appropriate error handling, into a separate function...

8ae6bb54 01/16/2008 06:01 pm Iustin Pop

Show the HVM boot order in instance info

This is a merge from the 1.2 branch

Reviewed-by: imsnah

ba4b62cf 01/14/2008 05:10 pm Iustin Pop

Fix some misspellings

This patch fixes two name typos and a style issue (which makes pylint
complain).

Reviewed-by: ultrotter

40ed12dd 01/14/2008 04:19 pm Guido Trotter

Fix CreateInstance new optional parameters

Some new paramenters of the CreateInstance opcode are optional (namely
kernel_path, initrd_path and hvm_boot_order) but their absence makes the code
crash. Fix this by initializing them to a default value if they're not present....

25c5878d 01/11/2008 02:13 pm Alexander Schreiber

Support selecting the boot device order for HVM.

This patch adds support for specifying and changing the boot device order for
HVM instances. The boot device order specification is ignored for non HVM
instances.

Reviewed-by: iustinp

8cafeb26 01/08/2008 06:16 pm Iustin Pop

Fix gnt-instance modify breakage introduced in r462

Reviewed-by: schreiberal

71aa8f73 01/08/2008 01:03 pm Iustin Pop

Make ‘gnt-instance info’ show kernel/initrd paths

This patch changes the info subcommand to nicely show the kernel and
initrd paths.

Reviewed-by: imsnah

3b6d8c9b 01/08/2008 01:03 pm Iustin Pop

Allow defining the kernel/initrd at creation time

This patch adds support for defining the kernel/initrd at instance
creation time, using the same interface as in instance modify.

Reviewed-by: imsnah

973d7867 01/08/2008 01:03 pm Iustin Pop

Add support for modifying the kernel/initrd path

This patch adds support in ‘gnt-instance modify’ to set the kernel and
initrd paths. The user can pass either 'default' or 'none' (none is not
valid for kernel).

Reviewed-by: imsnah

b63ed789 01/07/2008 03:30 pm Iustin Pop

Improve verify-disks: broken/missing LV detection

This patch improves the ‘gnt-cluster verify-disks’ command by adding
support for detecting broken volume groups and missing logical volume
names.

As such, we don't try anymore to activate disks for instances that are...

1862d460 12/27/2007 05:31 pm Alexander Schreiber

Allow instance MAC address to be set.

Allow the MAC address of an instance to be specified optionally during
instance creation and later to be changed via instance modify.

Reviewed-by: iustinp

2a6469d5 12/20/2007 06:47 pm Alexander Schreiber

Proof-of-Concept HVM support for Ganeti.

This patch implements a first proof-of-concept for HVM support in Ganeti.
Due to the nature of this patch, it is intended for test environments
only.

Reviewed-by: iustinp

30989e69 12/18/2007 04:25 pm Alexander Schreiber

Internal API change for instance console access.

Change the internal hypervisor API for GetShellCommandForConsole, we
now call it with the instance instead of just the instance name.

This is a prep patch for HVM, since HVM needs more than just the instance...

2584d4a4 12/18/2007 04:05 pm Alexander Schreiber

cleanup for hypervisor constants

Move constant definitions for hypervisor into constants.py

Reviewed-by: ultrotter

79caa9ed 12/18/2007 01:04 pm Guido Trotter

Specify hint as a named argument

hint is declared as a named argument for the LogWarning function. Make its
caller pass it naming it.

Reviewed-by: iustinp

58acb49d 12/17/2007 04:53 pm Alexander Schreiber

Add instance port support.

Extends the instance object by adding a port item, also adds changes
to print this port via gnt-instance info.

Reviewed-by: iustinp

2c95a8d4 12/12/2007 03:13 pm Iustin Pop

Add LUVerifyDisks

This patch adds a new LUVerifyDisks that implements the OpVerifyDisks.
The algorithm is that by determining not-used logical volumes for
instances that are supposed to be running, we presume from there that
the DRBD devices are not online and therefore one should...

f4bc1f2c 12/03/2007 04:03 pm Michael Hanselmann

Various code style fixes for strings.

- When line wrapping is needed, move spaces to the next line.
- Remove embedded line breaks from error messages.

Reviewed-by: schreiberal

8522ceeb 11/27/2007 04:15 pm Iustin Pop

Fix logging of some checks in LUClusterVerify

Currently, the results of ConfigWriter.VerifyConfig() are lost. Make
sure we log them too in cluster verify.

Reviewed-by: ultrotter

642445d9 11/26/2007 10:38 am Iustin Pop

Split the change of peer in secondary replace in two operations

This patch splits the single operation of replace peer into two distinct
phases, in order to make a single change to the instance configuration:
- detach from network
- if at least one drbd device succeeded, make one change to the...

12c3449a 11/21/2007 06:55 pm Michael Hanselmann

Replace disk template drbd8 with drbd where missing.

Reviewed-by: iustinp

6852c52f 11/16/2007 08:36 pm Guido Trotter

Fix a typo in a warning message

Reviewed-by: schreiberal

6510a58a 11/16/2007 04:28 pm Michael Hanselmann

Don't remove master's hostname from /etc/hosts on cluster destroy.

This fixes issue #13.

Reviewed-by: schreiberal

9440aeab 11/12/2007 07:09 pm Michael Hanselmann

Fix functions for /etc/hosts.

- Combine hostname and aliases on one line
- Fix bug with wrongfully removed newline characters
- Use wrapper for SetEtcHostsEntry in cmdlib

Reviewed-by: iustin

7df43a76 11/12/2007 05:56 am Iustin Pop

Relax replace_disks_all meaning for drbd8

In order to make the replace secondary action to be done via the same
opcode parameters for both remote_raid1 and drbd, we must allow the
LUReplaceDisks to change replace_disks_all for drbd with non-empty
remote_node into replace_disks_sec....

c8a0948f 11/09/2007 04:54 pm Michael Hanselmann

Use new functions to modify /etc/hosts.

Reviewed-by: schreiberal

5bfac263 11/08/2007 09:04 pm Iustin Pop

Changes related to logging

This patch modifes:
- mcpu.Processor.LogWarning to have its 'hint' parameter as optional
and only log it if not None
- cmdlib._WaitForSync to not log directly to stdout/stderr but via the
proc.Log(Info|Warning) methods...

0834c866 11/07/2007 05:53 pm Iustin Pop

Enhance secondary node replace for drbd8

This (big) patch does two things:
- add "local disk status" to the block device checks
(BlockDevice.GetSyncStatus and the rpc calls that call this
function, and therefore cmdlib._CheckDiskConsistency)
- improve the drbd8 secondary replace operation using the above...

7dd30006 11/07/2007 01:48 pm Michael Hanselmann

Check whether init.d script is executable.

Reviewed-by: schreiberal

cff90b79 11/06/2007 07:01 pm Iustin Pop

Enhance DBRD8 disk replacement (same nodes)

This patch adds enhanced reporting and much more checks to the disk
replacement (when not switching the secondary).

Reviewed-by: imsnah

c7b46d59 11/05/2007 07:59 pm Iustin Pop

Handle missing init script at cluster init

This patch adds a check in the prereq of LUInitCluster for the existence
of the init script. This allows a clean abort instead of a stack dump.

Based on a report by

Reviewed-by: ultrotter

65fe4693 11/05/2007 05:06 pm Iustin Pop

Miscellaneous style fixes

This patch fixes some minor pylint warnings (unused variables, wrong
indentation, etc.) and a real bug in the recovery for drbd8 rename
procedure.

Reviewed-by: imsnah

dfa96ded 11/05/2007 02:43 am Guido Trotter

Convert os_get to use OS rather than InvalidOS

In order to do this for simplicity we leave the OSFromDisk function as-is and
we convert the eventual exception to an OS object in ganeti-noded. The
unmangling gets simplified and so does the code for checking whether the OS is...

00fe9e38 11/04/2007 06:10 am Guido Trotter

Make call_os_get a single node function

call_os_get is never called with a real list of nodes, so there's no point in
it being multi-node. Making it single-node till a usage for multi-node call is
found.

Reviewed-By: iustinp

73415719 11/03/2007 08:55 am Iustin Pop

Implement tag searching

This patch adds a search command for locating tags on all objects of the
cluster using a regex pattern.

Reviewed-by: aat

3f78eef2 11/02/2007 03:44 pm Iustin Pop

Implement device to instance mapping cache

Currently, troubleshooting DRBD problems involves a manual process of going
backwards from the DRBD device to the instance that owns it.

This patch adds a weak (i.e. not guaranteed to be correct or up-to-date)
cache of device to instance. The cache should be, in normal operation,...

24a40d57 10/31/2007 04:56 pm Iustin Pop

More sane handling of errors during failover

Currently we ignore errors on instance shutdown (on the source node)
during instance failover. We should do this only if the user gave a
command line options allowing this, as it's a dangerous thing to do.

This patch fixes this by using the same "--ignore-consistency" option...

50ff9a7a 10/31/2007 04:55 pm Iustin Pop

Fix bridge checking in instance failover

The current code checks the bridge on the primary node of the instance,
but we need to check it on the destination node.

This was caught by testing failover with a down primary node.

Reviewed-by: imsnah

4cc2a728 10/30/2007 05:09 pm Michael Hanselmann

Fix _UpdateEtcHosts to understand empty lines.

Reviewed-by: schreiberal

1a8c0ce1 10/29/2007 10:09 pm Iustin Pop

Change the signature of some methods of mcpu.Processor

This patch moves the passing of the feedback_fn argument from the
(Exec|Chain)OpCode to the initialization of the Processor instance.

Reviewed-by: imsnah

a9e0c397 10/29/2007 05:49 pm Iustin Pop

Implement replace-disks for drbd8 devices

This patch adds three modes of disk replacement for drbd8:
- replace the disk on the primary node
- replace the disk on the secondary node
- replace the secondary node

It also adds some debugging code to backend.py and increments the...

153d9724 10/25/2007 02:22 pm Iustin Pop

Modify two mirror-device related rpc calls

The two calls mirror_addchild and mirror_removechild take only one child
for addition/removal. While this is enough for our md usage, for local
disk replacement in drbd8, we need to be able to specify both the data...

a1f445d3 10/24/2007 05:43 pm Iustin Pop

Initial implementation of drbd8 template type

This is a partially working drbd8 template type. It does:
- add/remove
- startup/failover/shutdown

Not working is replace disks, which needs custom code for this template.

Reviewed-by: imsnah

b352ab5b 10/24/2007 05:23 pm Iustin Pop

Fix a disk handling bug triggered by failover

This leaves an instance's disks configured for the primary node as after
disk activation we want to start the instance anyway. As such,
_GatherBlockDevs in backend.py will need the disks configured for the
primary....

fe96220b 10/19/2007 02:48 pm Iustin Pop

Abstract more strings values into constants

Currently, the disk types are defined using constants in the code.
Convert those into constants so that we can easily find them and check
their usage.

Note that we don't rename the values of the constants as they are used...

bf6929a2 10/18/2007 01:25 pm Alexander Schreiber

Patch series for reboot feature, part 2

This patch series implements the reboot command for gnt-instance. It
supports three types of reboot: soft (hypervisor reboot), hard (instance
config rebuild and reboot) and full (full instance shutdown and startup
again)....

6a438c98 10/16/2007 06:27 pm Michael Hanselmann

Make “gnt-cluster verify” exit 0 if there's no problem with instances.

Reviewed-by: schreiberal

f55ff7ec 10/16/2007 05:30 pm Iustin Pop

Add the number of VCPUs in gnt-instance info

Reviewed-by: imsnah

1d67656e 10/16/2007 04:51 pm Iustin Pop

Allow force removal of instances

This patch adds a new option to the instance removal command
"--ignore-failures" that forces the removal of the instance from the
configuration even if the removal process encounters errors.

In order to be able to do this when the remote node(s) is(are) down, we...

70d9e3d8 10/16/2007 11:28 am Iustin Pop

Replace more ssh paths with proper constants

The node's ssh keys filenames are now provided as constants; this should
allow easier customization.

Also, the user's ssh key computing has been abstracted into ssh.py

Reviewed-by: imsnah

0e137c28 10/11/2007 06:23 pm Iustin Pop

Some small improvements to the hooks environment

For the configuration update hook, it's useful to have a consistent name
for the target of the operation. As such, the LU code is modified to
include an GANETI_OP_TARGET that points either to the cluster (name),...

4167825b 10/11/2007 06:00 pm Iustin Pop

Split the hooks env building in two parts

This patch moves some of the environment processing from _BuildEnv to a
new _RunWrapper command which does the stringification and adds the
sstore variables.

The reasoning is that the sstore can be fresher than before the...

16abfbc2 10/10/2007 08:20 pm Alexander Schreiber

Remove fping as a dependency for Ganeti.

This patch completely gets rid of fping
- replace all fping invocations with TcpPing calls
- update documentation accordingly.
- associated cleanups (use constant for localhost IP, use more sensible
defaults for TcpPing and use those)...

2f31098c 10/10/2007 01:00 pm Iustin Pop

Remove the shebang from modules

Since modules are not directly executables, remove the shebang from
them. This helps with lintian warnings.

Also make the autogenerated _autoconf.py contain two comment lines at
the beginning, like the other modules.

Reviewed-by: ultrotter

3ef10550 10/08/2007 06:18 pm Michael Hanselmann

Add boot id to “gnt-node list”.

Reviewed-by: iustinp

f27302fa 10/08/2007 06:10 pm Iustin Pop

Change tags add/remove to process multiple tags

This patch changes the tags opcodes to work with multiple tags at once
instead of only one. As such, the opcodes and some parameters are
renamed.

Reviewed-by: imsnah

8f684e16 10/08/2007 06:10 pm Iustin Pop

Fix tags operations for instances

Reviewed-by: imsnah

89e1fc26 09/21/2007 04:37 pm Iustin Pop

Remove requirement that host names are FQDN

We currently require that hostnames are FQDN not short names
(node1.example.com instead of node1). We can allow short names as long
as:
- we always resolve the names as returned by socket.gethostname()
- we rely on having a working resolver...

bdd55f71 09/19/2007 04:52 pm Iustin Pop

Allow 'add instance' to not start the new instance

This patch allows 'gnt-instance add' to not start the newly-created
instance. It also allow 'gnt-instance add' and 'gnt-backup import' to
not check for IP conflicts (only when not starting the instance)....

bcf043c9 09/19/2007 09:56 am Iustin Pop

Change resolved hostname from dict to a class

The current result of utils.LookupHostname() is a dict, but this does
not allow static checkers to check the correctness of the code. This
patch introduces a new class names HostInfo and changes LookupHostname...

07bd8a51 09/18/2007 03:42 pm Iustin Pop

Implement cluster rename operation

This patch adds a new OpCode (and corresponding LU) that implements the
cluster rename functionality.

This is done by shutting down the master role, making the needed sstore
modifications and distributing the changed files to all nodes, and then...

decd5f45 09/17/2007 02:52 pm Iustin Pop

Implement instance rename operation

This patch adds support for instance rename operation at all remaining
layers: RPC, OpCode/LU and CLI.

Reviewed-by: imsnah

246e180a 09/14/2007 12:54 pm Iustin Pop

Change OpQueryNodes nodes attribute to names

Change this to have the exact same parameters as OpQueryInstances.

Also fix burnin which is broken since r146.

Reviewed-by: imsnah

069dcc86 09/14/2007 12:54 pm Iustin Pop

Enable LUQueryInstances to work with a given list of instances

As per the changes to LUQueryNodes, the QueryInstances LU is modified to
accept a list of instances for which to compute and return information.

Reviewed-by: imsnah

4a72cc75 09/14/2007 12:03 pm Iustin Pop

Remove OpQueryNodeData and LUQueryNodeData

Now that LUQueryNodes supports all the functionality of LUQueryNodeData,
let's migrate gnt-node.ShowNodeConfig to use it and remove all traces of
OpQueryNodeData and LUQueryNodeData.

Reviewed-by: imsnah