Fix for man entry for htools - added hinfo
[ganeti-local] / man / gnt-cluster.rst
index 062d55a..8082d14 100644 (file)
@@ -20,10 +20,17 @@ Ganeti system.
 COMMANDS
 --------
 
+ACTIVATE-MASTER-IP
+~~~~~~~~~~~~~~~~~~
+
+**activate-master-ip**
+
+Activates the master IP on the master node.
+
 ADD-TAGS
 ~~~~~~~~
 
-**add-tags** [--from *file*] {*tag*...}
+**add-tags** [\--from *file*] {*tag*...}
 
 Add tags to the cluster. If any of the tags contains invalid
 characters, the entire operation will abort.
@@ -37,7 +44,7 @@ interpreted as stdin.
 COMMAND
 ~~~~~~~
 
-**command** [-n *node*] {*command*}
+**command** [-n *node*] [-g *group*] [-M] {*command*}
 
 Executes a command on all nodes. If the option ``-n`` is not given,
 the command will be executed on all nodes, otherwise it will be
@@ -46,6 +53,14 @@ times for running it on multiple nodes, like::
 
     # gnt-cluster command -n node1.example.com -n node2.example.com date
 
+The ``-g`` option can be used to run a command only on a specific node
+group, e.g.::
+
+    # gnt-cluster command -g default date
+
+The ``-M`` option can be used to prepend the node name to all output
+lines.
+
 The command is executed serially on the selected nodes. If the
 master node is present in the list, the command will be executed
 last on the master. Regarding the other nodes, the execution order
@@ -67,12 +82,14 @@ and the command which will be executed will be ``ls -l /etc``.
 COPYFILE
 ~~~~~~~~
 
-**copyfile** [--use-replication-network] [-n *node*] {*file*}
+| **copyfile** [\--use-replication-network] [-n *node*] [-g *group*]
+| {*file*}
 
 Copies a file to all or to some nodes. The argument specifies the
 source file (on the current system), the ``-n`` argument specifies
 the target node, or nodes if the option is given multiple times. If
-``-n`` is not given at all, the file will be copied to all nodes.
+``-n`` is not given at all, the file will be copied to all nodes. The
+``-g`` option can be used to only select nodes in a specific node group.
 Passing the ``--use-replication-network`` option will cause the
 copy to be done over the replication network (only matters if the
 primary/secondary IPs are different). Example::
@@ -82,16 +99,49 @@ primary/secondary IPs are different). Example::
 This will copy the file /tmp/test from the current node to the two
 named nodes.
 
+DEACTIVATE-MASTER-IP
+~~~~~~~~~~~~~~~~~~~~
+
+**deactivate-master-ip** [\--yes]
+
+Deactivates the master IP on the master node.
+
+This should be run only locally or on a connection to the node ip
+directly, as a connection to the master ip will be broken by this
+operation. Because of this risk it will require user confirmation
+unless the ``--yes`` option is passed.
+
 DESTROY
 ~~~~~~~
 
-**destroy** {--yes-do-it}
+**destroy** {\--yes-do-it}
 
 Remove all configuration files related to the cluster, so that a
 **gnt-cluster init** can be done again afterwards.
 
 Since this is a dangerous command, you are required to pass the
-argument *--yes-do-it.*
+argument *\--yes-do-it.*
+
+EPO
+~~~
+
+**epo** [\--on] [\--groups|\--all] [\--power-delay] *arguments*
+
+Performs an emergency power-off on nodes given as arguments. If
+``--groups`` is given, arguments are node groups. If ``--all`` is
+provided, the whole cluster will be shut down.
+
+The ``--on`` flag recovers the cluster after an emergency power-off.
+When powering on the cluster you can use ``--power-delay`` to define the
+time in seconds (fractions allowed) waited between powering on
+individual nodes.
+
+Please note that the master node will not be turned down or up
+automatically.  It will just be left in a state, where you can manully
+perform the shutdown of that one node. If the master is in the list of
+affected nodes and this is not a complete cluster emergency power-off
+(e.g. using ``--all``), you're required to do a master failover to
+another node not affected.
 
 GETMASTER
 ~~~~~~~~~
@@ -103,7 +153,7 @@ Displays the current master node.
 INFO
 ~~~~
 
-**info** [--roman]
+**info** [\--roman]
 
 Shows runtime cluster information: cluster name, architecture (32
 or 64 bit), master node, node list and instance list.
@@ -116,26 +166,36 @@ INIT
 ~~~~
 
 | **init**
-| [{-s|--secondary-ip} *secondary\_ip*]
-| [--vg-name *vg-name*]
-| [--master-netdev *interface-name*]
-| [{-m|--mac-prefix} *mac-prefix*]
-| [--no-lvm-storage]
-| [--no-etc-hosts]
-| [--no-ssh-init]
-| [--file-storage-dir *dir*]
-| [--enabled-hypervisors *hypervisors*]
-| [-t *hypervisor name*]
-| [{-H|--hypervisor-parameters} *hypervisor*:*hv-param*=*value*[,*hv-param*=*value*...]]
-| [{-B|--backend-parameters} *be-param*=*value* [,*be-param*=*value*...]]
-| [{-N|--nic-parameters} *nic-param*=*value* [,*nic-param*=*value*...]]
-| [--maintain-node-health {yes \| no}]
-| [--uid-pool *user-id pool definition*]
-| [{-I|--default-iallocator} *default instance allocator*]
-| [--primary-ip-version *version*]
-| [--prealloc-wipe-disks {yes \| no}]
-| [--node-parameters *ndparams*]
-| [{-C|--candidate-pool-size} *candidate\_pool\_size*]
+| [{-s|\--secondary-ip} *secondary\_ip*]
+| [\--vg-name *vg-name*]
+| [\--master-netdev *interface-name*]
+| [\--master-netmask *netmask*]
+| [\--use-external-mip-script {yes \| no}]
+| [{-m|\--mac-prefix} *mac-prefix*]
+| [\--no-lvm-storage]
+| [\--no-etc-hosts]
+| [\--no-ssh-init]
+| [\--file-storage-dir *dir*]
+| [\--enabled-hypervisors *hypervisors*]
+| [{-H|\--hypervisor-parameters} *hypervisor*:*hv-param*=*value*[,*hv-param*=*value*...]]
+| [{-B|\--backend-parameters} *be-param*=*value*[,*be-param*=*value*...]]
+| [{-N|\--nic-parameters} *nic-param*=*value*[,*nic-param*=*value*...]]
+| [{-D|\--disk-parameters} *disk-template*:*disk-param*=*value*[,*disk-param*=*value*...]]
+| [\--maintain-node-health {yes \| no}]
+| [\--uid-pool *user-id pool definition*]
+| [{-I|\--default-iallocator} *default instance allocator*]
+| [\--primary-ip-version *version*]
+| [\--prealloc-wipe-disks {yes \| no}]
+| [\--node-parameters *ndparams*]
+| [{-C|\--candidate-pool-size} *candidate\_pool\_size*]
+| [\--specs-cpu-count *spec-param*=*value* [,*spec-param*=*value*...]]
+| [\--specs-disk-count *spec-param*=*value* [,*spec-param*=*value*...]]
+| [\--specs-disk-size *spec-param*=*value* [,*spec-param*=*value*...]]
+| [\--specs-mem-size *spec-param*=*value* [,*spec-param*=*value*...]]
+| [\--specs-nic-count *spec-param*=*value* [,*spec-param*=*value*...]]
+| [\--ipol-disk-templates *template* [,*template*...]]
+| [\--disk-state *diskstate*]
+| [\--hypervisor-state *hvstate*]
 | {*clustername*}
 
 This commands is only run once initially on the first node of the
@@ -176,6 +236,17 @@ interface on which the master will activate its IP address. It's
 important that all nodes have this interface because you'll need it
 for a master failover.
 
+The ``--master-netmask`` option allows to specify a netmask for the
+master IP. The netmask must be specified as an integer, and will be
+interpreted as a CIDR netmask. The default value is 32 for an IPv4
+address and 128 for an IPv6 address.
+
+The ``--use-external-mip-script`` option allows to specify whether to
+use an user-supplied master IP address setup script, whose location is
+``@SYSCONFDIR@/ganeti/scripts/master-ip-setup``. If the option value is
+set to False, the default script (located at
+``@PKGLIBDIR@/tools/master-ip-setup``) will be executed.
+
 The ``-m (--mac-prefix)`` option will let you specify a three byte
 prefix under which the virtual MAC addresses of your instances will be
 generated. The prefix must be specified in the format ``XX:XX:XX`` and
@@ -262,16 +333,26 @@ vcpus
     Number of VCPUs to set for an instance by default, must be an
     integer, will be set to 1 if no specified.
 
-memory
-    Amount of memory to allocate for an instance by default, can be
-    either an integer or an integer followed by a unit (M for mebibytes
-    and G for gibibytes are supported), will be set to 128M if not
-    specified.
+maxmem
+    Maximum amount of memory to allocate for an instance by default, can
+    be either an integer or an integer followed by a unit (M for
+    mebibytes and G for gibibytes are supported), will be set to 128M if
+    not specified.
+
+minmem
+    Minimum amount of memory to allocate for an instance by default, can
+    be either an integer or an integer followed by a unit (M for
+    mebibytes and G for gibibytes are supported), will be set to 128M if
+    not specified.
 
 auto\_balance
     Value of the auto\_balance flag for instances to use by default,
     will be set to true if not specified.
 
+always\_failover
+    Default value for the ``always\_failover`` flag for instances; if
+    not set, ``False`` is used.
+
 
 The ``-N (--nic-parameters)`` option allows you to set the default nic
 parameters for the cluster. The parameter format is a comma-separated
@@ -287,11 +368,96 @@ link
     network script it is interpreted as a routing table number or
     name.
 
+The ``-D (--disk-parameters)`` option allows you to set the default disk
+template parameters at cluster level. The format used for this option is
+similar to the one use by the  ``-H`` option: the disk template name
+must be specified first, followed by a colon and by a comma-separated
+list of key-value pairs. These parameters can only be specified at
+cluster and node group level; the cluster-level parameter are inherited
+by the node group at the moment of its creation, and can be further
+modified at node group level using the **gnt-group**(8) command.
+
+The following is the list of disk parameters available for the **drbd**
+template, with measurement units specified in square brackets at the end
+of the description (when applicable):
+
+resync-rate
+    Static re-synchronization rate. [KiB/s]
+
+data-stripes
+    Number of stripes to use for data LVs.
+
+meta-stripes
+    Number of stripes to use for meta LVs.
+
+disk-barriers
+    What kind of barriers to **disable** for disks. It can either assume
+    the value "n", meaning no barrier disabled, or a non-empty string
+    containing a subset of the characters "bfd". "b" means disable disk
+    barriers, "f" means disable disk flushes, "d" disables disk drains.
+
+meta-barriers
+    Boolean value indicating whether the meta barriers should be
+    disabled (True) or not (False).
+
+metavg
+    String containing the name of the default LVM volume group for DRBD
+    metadata. By default, it is set to ``xenvg``. It can be overridden
+    during the instance creation process by using the ``metavg`` key of
+    the ``--disk`` parameter.
+
+disk-custom
+    String containing additional parameters to be appended to the
+    arguments list of ``drbdsetup disk``.
+
+net-custom
+    String containing additional parameters to be appended to the
+    arguments list of ``drbdsetup net``.
+
+dynamic-resync
+    Boolean indicating whether to use the dynamic resync speed
+    controller or not. If enabled, c-plan-ahead must be non-zero and all
+    the c-* parameters will be used by DRBD. Otherwise, the value of
+    resync-rate will be used as a static resync speed.
+
+c-plan-ahead
+    Agility factor of the dynamic resync speed controller. (the higher,
+    the slower the algorithm will adapt the resync speed). A value of 0
+    (that is the default) disables the controller. [ds]
+
+c-fill-target
+    Maximum amount of in-flight resync data for the dynamic resync speed
+    controller. [sectors]
+
+c-delay-target
+    Maximum estimated peer response latency for the dynamic resync speed
+    controller. [ds]
+
+c-min-rate
+    Minimum resync speed for the dynamic resync speed controller. [KiB/s]
+
+c-max-rate
+    Upper bound on resync speed for the dynamic resync speed controller.
+    [KiB/s]
+
+List of parameters available for the **plain** template:
+
+stripes
+    Number of stripes to use for new LVs.
+
+List of parameters available for the **rbd** template:
+
+pool
+    The RADOS cluster pool, inside which all rbd volumes will reside.
+    When a new RADOS cluster is deployed, the default pool to put rbd
+    volumes (Images in RADOS terminology) is 'rbd'.
+
 The option ``--maintain-node-health`` allows one to enable/disable
 automatic maintenance actions on nodes. Currently these include
 automatic shutdown of instances and deactivation of DRBD devices on
 offline nodes; in the future it might be extended to automatic
-removal of unknown LVM volumes, etc.
+removal of unknown LVM volumes, etc. Note that this option is only
+useful if the use of ``ganeti-confd`` was enabled at compilation.
 
 The ``--uid-pool`` option initializes the user-id pool. The
 *user-id pool definition* can contain a list of user-ids and/or a
@@ -303,14 +469,16 @@ user-id pool is initialized to an empty list. An empty list means
 that the user-id pool feature is disabled.
 
 The ``-I (--default-iallocator)`` option specifies the default
-instance allocator. The instance allocator will be used for
-operations like instance creation, instance and node migration,
-etc. when no manual override is specified. If this option is not
-specified, the default instance allocator will be blank, which
-means that relevant operations will require the administrator to
-manually specify either an instance allocator, or a set of nodes.
-The default iallocator can be changed later using the **modify**
-command.
+instance allocator. The instance allocator will be used for operations
+like instance creation, instance and node migration, etc. when no
+manual override is specified. If this option is not specified and
+htools was not enabled at build time, the default instance allocator
+will be blank, which means that relevant operations will require the
+administrator to manually specify either an instance allocator, or a
+set of nodes. If the option is not specified but htools was enabled,
+the default iallocator will be **hail**(1) (assuming it can be found
+on disk). The default iallocator can be changed later using the
+**modify** command.
 
 The ``--primary-ip-version`` option specifies the IP version used
 for the primary address. Possible values are 4 and 6 for IPv4 and
@@ -326,6 +494,26 @@ The ``-C (--candidate-pool-size)`` option specifies the
 that the master will try to keep as master\_candidates. For more
 details about this role and other node roles, see the ganeti(7).
 
+The ``--specs-...`` and ``--ipol-disk-templates`` options specify
+instance policy on the cluster. For the ``--specs-...`` options, each
+option can have three values: ``min``, ``max`` and ``std``, which can
+also be modified on group level (except for ``std``, which is defined
+once for the entire cluster). Please note, that ``std`` values are not
+the same as defaults set by ``--beparams``, but they are used for the
+capacity calculations. The ``--ipol-disk-templates`` option takes a
+comma-separated list of disk templates.
+
+- ``--specs-cpu-count`` limits the number of VCPUs that can be used by an
+  instance.
+- ``--specs-disk-count`` limits the number of disks
+- ``--specs-disk-size`` limits the disk size for every disk used
+- ``--specs-mem-size`` limits the amount of memory available
+- ``--specs-nic-count`` sets limits on the number of NICs used
+- ``--ipol-disk-templates`` limits the allowed disk templates
+
+For details about how to use ``--hypervisor-state`` and ``--disk-state``
+have a look at **ganeti**(7).
+
 LIST-TAGS
 ~~~~~~~~~
 
@@ -336,7 +524,7 @@ List the tags of the cluster.
 MASTER-FAILOVER
 ~~~~~~~~~~~~~~~
 
-**master-failover** [--no-voting]
+**master-failover** [\--no-voting]
 
 Failover the master role to the current node.
 
@@ -366,32 +554,49 @@ be 1.
 MODIFY
 ~~~~~~
 
-| **modify**
-| [--vg-name *vg-name*]
-| [--no-lvm-storage]
-| [--enabled-hypervisors *hypervisors*]
-| [{-H|--hypervisor-parameters} *hypervisor*:*hv-param*=*value*[,*hv-param*=*value*...]]
-| [{-B|--backend-parameters} *be-param*=*value* [,*be-param*=*value*...]]
-| [{-N|--nic-parameters} *nic-param*=*value* [,*nic-param*=*value*...]]
-| [--uid-pool *user-id pool definition*]
-| [--add-uids *user-id pool definition*]
-| [--remove-uids *user-id pool definition*]
-| [{-C|--candidate-pool-size} *candidate\_pool\_size*]
-| [--maintain-node-health {yes \| no}]
-| [--prealloc-wipe-disks {yes \| no}]
-| [{-I|--default-iallocator} *default instance allocator*]
-| [--reserved-lvs=*NAMES*]
-| [--node-parameters *ndparams*]
-| [--master-netdev *interface-name*]
+| **modify** [\--submit]
+| [\--vg-name *vg-name*]
+| [\--no-lvm-storage]
+| [\--enabled-hypervisors *hypervisors*]
+| [{-H|\--hypervisor-parameters} *hypervisor*:*hv-param*=*value*[,*hv-param*=*value*...]]
+| [{-B|\--backend-parameters} *be-param*=*value*[,*be-param*=*value*...]]
+| [{-N|\--nic-parameters} *nic-param*=*value*[,*nic-param*=*value*...]]
+| [{-D|\--disk-parameters} *disk-template*:*disk-param*=*value*[,*disk-param*=*value*...]]
+| [\--uid-pool *user-id pool definition*]
+| [\--add-uids *user-id pool definition*]
+| [\--remove-uids *user-id pool definition*]
+| [{-C|\--candidate-pool-size} *candidate\_pool\_size*]
+| [\--maintain-node-health {yes \| no}]
+| [\--prealloc-wipe-disks {yes \| no}]
+| [{-I|\--default-iallocator} *default instance allocator*]
+| [\--reserved-lvs=*NAMES*]
+| [\--node-parameters *ndparams*]
+| [\--master-netdev *interface-name*]
+| [\--master-netmask *netmask*]
+| [\--use-external-mip-script {yes \| no}]
+| [\--hypervisor-state *hvstate*]
+| [\--disk-state *diskstate*]
+| [\--specs-cpu-count *spec-param*=*value* [,*spec-param*=*value*...]]
+| [\--specs-disk-count *spec-param*=*value* [,*spec-param*=*value*...]]
+| [\--specs-disk-size *spec-param*=*value* [,*spec-param*=*value*...]]
+| [\--specs-mem-size *spec-param*=*value* [,*spec-param*=*value*...]]
+| [\--specs-nic-count *spec-param*=*value* [,*spec-param*=*value*...]]
+| [\--ipol-disk-templates *template* [,*template*...]]
+
 
 Modify the options for the cluster.
 
 The ``--vg-name``, ``--no-lvm-storarge``, ``--enabled-hypervisors``,
 ``-H (--hypervisor-parameters)``, ``-B (--backend-parameters)``,
-``--nic-parameters``, ``-C (--candidate-pool-size)``,
-``--maintain-node-health``, ``--prealloc-wipe-disks``, ``--uid-pool``,
-``--node-parameters``, ``--master-netdev`` options are described in
-the **init** command.
+``-D (--disk-parameters)``, ``--nic-parameters``, ``-C
+(--candidate-pool-size)``, ``--maintain-node-health``,
+``--prealloc-wipe-disks``, ``--uid-pool``, ``--node-parameters``,
+``--master-netdev``, ``--master-netmask`` and
+``--use-external-mip-script`` options are described in the **init**
+command.
+
+The ``--hypervisor-state`` and ``--disk-state`` options are described in
+detail in **ganeti(7)**.
 
 The ``--add-uids`` and ``--remove-uids`` options can be used to
 modify the user-id pool by adding/removing a list of user-ids or
@@ -413,6 +618,12 @@ The ``-I (--default-iallocator)`` is described in the **init**
 command. To clear the default iallocator, just pass an empty string
 ('').
 
+The ``--specs-...`` and ``--ipol-disk-templates`` options are described
+in the **init** command.
+
+See **ganeti(7)** for a description of ``--submit`` and other common
+options.
+
 QUEUE
 ~~~~~
 
@@ -443,24 +654,23 @@ The ``continue`` option will let the watcher continue.
 
 The ``info`` option shows whether the watcher is currently paused.
 
-redist-conf
+REDIST-CONF
 ~~~~~~~~~~~
 
-**redist-conf** [--submit]
+**redist-conf** [\--submit]
 
 This command forces a full push of configuration files from the
 master node to the other nodes in the cluster. This is normally not
 needed, but can be run if the **verify** complains about
 configuration mismatches.
 
-The ``--submit`` option is used to send the job to the master
-daemon but not wait for its completion. The job ID will be shown so
-that it can be examined via **gnt-job info**.
+See **ganeti(7)** for a description of ``--submit`` and other common
+options.
 
 REMOVE-TAGS
 ~~~~~~~~~~~
 
-**remove-tags** [--from *file*] {*tag*...}
+**remove-tags** [\--from *file*] {*tag*...}
 
 Remove tags from the cluster. If any of the tags are not existing
 on the cluster, the entire operation will abort.
@@ -489,9 +699,11 @@ RENEW-CRYPTO
 ~~~~~~~~~~~~
 
 | **renew-crypto** [-f]
-| [--new-cluster-certificate] [--new-confd-hmac-key]
-| [--new-rapi-certificate] [--rapi-certificate *rapi-cert*]
-| [--new-cluster-domain-secret] [--cluster-domain-secret *filename*]
+| [\--new-cluster-certificate] [\--new-confd-hmac-key]
+| [\--new-rapi-certificate] [\--rapi-certificate *rapi-cert*]
+| [\--new-spice-certificate | \--spice-certificate *spice-cert*
+| \--spice-ca-certificate *spice-ca-cert*]
+| [\--new-cluster-domain-secret] [\--cluster-domain-secret *filename*]
 
 This command will stop all Ganeti daemons in the cluster and start
 them again once the new certificates and keys are replicated. The
@@ -504,6 +716,12 @@ ganeti-rapi(8)) specify ``--new-rapi-certificate``. If you want to
 use your own certificate, e.g. one signed by a certificate
 authority (CA), pass its filename to ``--rapi-certificate``.
 
+To generate a new self-signed SPICE certificate, used by SPICE
+connections to the KVM hypervisor, specify the
+``--new-spice-certificate`` option. If you want to provide a
+certificate, pass its filename to ``--spice-certificate`` and pass the
+signing CA certificate to ``--spice-ca-certificate``.
+
 ``--new-cluster-domain-secret`` generates a new, random cluster
 domain secret. ``--cluster-domain-secret`` reads the secret from a
 file. The cluster domain secret is used to sign information
@@ -522,7 +740,7 @@ arguments are given, all instances will be checked.
 
 Note that only active disks can be checked by this command; in case
 a disk cannot be activated it's advised to use
-**gnt-instance activate-disks --ignore-size ...** to force
+**gnt-instance activate-disks \--ignore-size ...** to force
 activation without regard to the current size.
 
 When the all disk sizes are consistent, the command will return no
@@ -556,7 +774,9 @@ node will be listed as /nodes/*name*, and an instance as
 VERIFY
 ~~~~~~
 
-**verify** [--no-nplus1-mem]
+| **verify** [\--no-nplus1-mem] [\--node-group *nodegroup*]
+| [\--error-codes] [{-I|\--ignore-errors} *errorcode*]
+| [{-I|\--ignore-errors} *errorcode*...]
 
 Verify correctness of cluster configuration. This is safe with
 respect to running instances, and incurs no downtime of the
@@ -566,6 +786,44 @@ If the ``--no-nplus1-mem`` option is given, Ganeti won't check
 whether if it loses a node it can restart all the instances on
 their secondaries (and report an error otherwise).
 
+With ``--node-group``, restrict the verification to those nodes and
+instances that live in the named group. This will not verify global
+settings, but will allow to perform verification of a group while other
+operations are ongoing in other groups.
+
+The ``--error-codes`` option outputs each error in the following
+parseable format: *ftype*:*ecode*:*edomain*:*name*:*msg*.
+These fields have the following meaning:
+
+ftype
+    Failure type. Can be *WARNING* or *ERROR*.
+
+ecode
+    Error code of the failure. See below for a list of error codes.
+
+edomain
+    Can be *cluster*, *node* or *instance*.
+
+name
+    Contains the name of the item that is affected from the failure.
+
+msg
+    Contains a descriptive error message about the error
+
+``gnt-cluster verify`` will have a non-zero exit code if at least one of
+the failures that are found are of type *ERROR*.
+
+The ``--ignore-errors`` option can be used to change this behaviour,
+because it demotes the error represented by the error code received as a
+parameter to a warning. The option must be repeated for each error that
+should be ignored (e.g.: ``-I ENODEVERSION -I ENODEORPHANLV``). The
+``--error-codes`` option can be used to determine the error code of a
+given error.
+
+List of error codes:
+
+@CONSTANTS_ECODES@
+
 VERIFY-DISKS
 ~~~~~~~~~~~~
 
@@ -585,3 +843,9 @@ VERSION
 **version**
 
 Show the cluster version.
+
+.. vim: set textwidth=72 :
+.. Local Variables:
+.. mode: rst
+.. fill-column: 72
+.. End: