2 - more tweaks to the disk activation code (especially helpful for DRBD)
3 - change the default ‘gnt-instance list’ output format, now there is
4 one combined status field (see the manpage for the exact values this
6 - some more fixes for the mac export to hooks change
7 - make Ganeti not break with DRBD 8.2.x (which changed the version
8 format in /proc/drbd) (issue 24)
9 - add an upgrade tool from ‘remote_raid1’ disk template to ‘drbd’ disk
10 template, allowing migration from DRBD0.7+MD to DRBD8
13 - fix ‘gnt-instance modify’ breakage introduced in 1.2.1 with the HVM
15 - add command aliases infrastructure and a few aliases
16 - allow listing of VCPUs in the gnt-instance list and improve the man
17 pages and the --help option of gnt-node/gnt-instance list
18 - fix gnt-backup list with down nodes (issue 21)
19 - change the tools location (move from $pkgdatadir to
21 - fix the dist archive and add a check for including svn/git files in
23 - some developer-related changes: improve the burnin and the QA
24 suite, add an upload script for testing during development
27 - experimental HVM support, read the install document, section
28 "Initializing the cluster"
29 - allow for the PVM hypervisor per-instance kernel and initrd paths
30 - add a new command ‘gnt-cluster verify-disks’ which uses a new
31 algorithm to improve the reconnection of the DRBD pairs if the
32 device on the secondary node has gone away
33 - make logical volume code auto-activate LVs at disk activation time
34 - slightly improve the speed of activating disks
35 - allow specification of the MAC address at instance creation time,
36 and changing it later via ‘gnt-instance modify’
37 - fix handling of external commands that generate lots of output on
39 - update documentation with regard to minimum version of DRBD8
43 - Log the ‘xm create’ output to the node daemon log on failure (to
44 help diagnosing the error)
45 - In debug mode, log all external commands output if failed to the
47 - Change parsing of lvm commands to ignore stderr
50 - Another round of updates to the DRBD 8 code to deal with more
51 failures in the replace secondary node operation
52 - Some more logging of failures in disk operations (lvm, drbd)
53 - A few documentation updates
57 - Change configuration file format from Python's Pickle to JSON.
58 Upgrading is possible using the cfgupgrade utility.
59 - Add support for DRBD 8.0 (new disk template `drbd`) which allows for
60 faster replace disks and is more stable (DRBD 8 has many
61 improvements compared to DRBD 0.7)
62 - Added command line tags support (see man pages for gnt-instance,
63 gnt-node, gnt-cluster)
64 - Added instance rename support
65 - Added multi-instance startup/shutdown
66 - Added cluster rename support
67 - Added `gnt-node evacuate` to simplify some node operations
68 - Added instance reboot operation that can speedup reboot as compared
70 - Soften the requirement that hostnames are in FQDN format
71 - The ganeti-watcher now activates drbd pairs after secondary node
73 - Removed dependency on debian's patched fping that uses the
74 non-standard -S option
75 - Now the OS definitions are searched for in multiple, configurable
76 paths (easier for distros to package)
77 - Some changes to the hooks infrastructure (especially the new
78 post-configuration update hook)
79 - Other small bugfixes