A few updates to the confd design (2.1)
[ganeti-local] / doc / design-2.1.rst
1 =================
2 Ganeti 2.1 design
3 =================
4
5 This document describes the major changes in Ganeti 2.1 compared to
6 the 2.0 version.
7
8 The 2.1 version will be a relatively small release. Its main aim is to
9 avoid changing too much of the core code, while addressing issues and
10 adding new features and improvements over 2.0, in a timely fashion.
11
12 .. contents:: :depth: 4
13
14 Objective
15 =========
16
17 Ganeti 2.1 will add features to help further automatization of cluster
18 operations, further improve scalability to even bigger clusters, and
19 make it easier to debug the Ganeti core.
20
21 Detailed design
22 ===============
23
24 As for 2.0 we divide the 2.1 design into three areas:
25
26 - core changes, which affect the master daemon/job queue/locking or
27   all/most logical units
28 - logical unit/feature changes
29 - external interface changes (eg. command line, os api, hooks, ...)
30
31 Core changes
32 ------------
33
34 Storage units modelling
35 ~~~~~~~~~~~~~~~~~~~~~~~
36
37 Currently, Ganeti has a good model of the block devices for instances
38 (e.g. LVM logical volumes, files, DRBD devices, etc.) but none of the
39 storage pools that are providing the space for these front-end
40 devices. For example, there are hardcoded inter-node RPC calls for
41 volume group listing, file storage creation/deletion, etc.
42
43 The storage units framework will implement a generic handling for all
44 kinds of storage backends:
45
46 - LVM physical volumes
47 - LVM volume groups
48 - File-based storage directories
49 - any other future storage method
50
51 There will be a generic list of methods that each storage unit type
52 will provide, like:
53
54 - list of storage units of this type
55 - check status of the storage unit
56
57 Additionally, there will be specific methods for each method, for
58 example:
59
60 - enable/disable allocations on a specific PV
61 - file storage directory creation/deletion
62 - VG consistency fixing
63
64 This will allow a much better modeling and unification of the various
65 RPC calls related to backend storage pool in the future. Ganeti 2.1 is
66 intended to add the basics of the framework, and not necessarilly move
67 all the curent VG/FileBased operations to it.
68
69 Note that while we model both LVM PVs and LVM VGs, the framework will
70 **not** model any relationship between the different types. In other
71 words, we don't model neither inheritances nor stacking, since this is
72 too complex for our needs. While a ``vgreduce`` operation on a LVM VG
73 could actually remove a PV from it, this will not be handled at the
74 framework level, but at individual operation level. The goal is that
75 this is a lightweight framework, for abstracting the different storage
76 operation, and not for modelling the storage hierarchy.
77
78
79 Locking improvements
80 ~~~~~~~~~~~~~~~~~~~~
81
82 Current State and shortcomings
83 ++++++++++++++++++++++++++++++
84
85 The class ``LockSet`` (see ``lib/locking.py``) is a container for one or
86 many ``SharedLock`` instances. It provides an interface to add/remove
87 locks and to acquire and subsequently release any number of those locks
88 contained in it.
89
90 Locks in a ``LockSet`` are always acquired in alphabetic order. Due to
91 the way we're using locks for nodes and instances (the single cluster
92 lock isn't affected by this issue) this can lead to long delays when
93 acquiring locks if another operation tries to acquire multiple locks but
94 has to wait for yet another operation.
95
96 In the following demonstration we assume to have the instance locks
97 ``inst1``, ``inst2``, ``inst3`` and ``inst4``.
98
99 #. Operation A grabs lock for instance ``inst4``.
100 #. Operation B wants to acquire all instance locks in alphabetic order,
101    but it has to wait for ``inst4``.
102 #. Operation C tries to lock ``inst1``, but it has to wait until
103    Operation B (which is trying to acquire all locks) releases the lock
104    again.
105 #. Operation A finishes and releases lock on ``inst4``. Operation B can
106    continue and eventually releases all locks.
107 #. Operation C can get ``inst1`` lock and finishes.
108
109 Technically there's no need for Operation C to wait for Operation A, and
110 subsequently Operation B, to finish. Operation B can't continue until
111 Operation A is done (it has to wait for ``inst4``), anyway.
112
113 Proposed changes
114 ++++++++++++++++
115
116 Non-blocking lock acquiring
117 ^^^^^^^^^^^^^^^^^^^^^^^^^^^
118
119 Acquiring locks for OpCode execution is always done in blocking mode.
120 They won't return until the lock has successfully been acquired (or an
121 error occurred, although we won't cover that case here).
122
123 ``SharedLock`` and ``LockSet`` must be able to be acquired in a
124 non-blocking way. They must support a timeout and abort trying to
125 acquire the lock(s) after the specified amount of time.
126
127 Retry acquiring locks
128 ^^^^^^^^^^^^^^^^^^^^^
129
130 To prevent other operations from waiting for a long time, such as
131 described in the demonstration before, ``LockSet`` must not keep locks
132 for a prolonged period of time when trying to acquire two or more locks.
133 Instead it should, with an increasing timeout for acquiring all locks,
134 release all locks again and sleep some time if it fails to acquire all
135 requested locks.
136
137 A good timeout value needs to be determined. In any case should
138 ``LockSet`` proceed to acquire locks in blocking mode after a few
139 (unsuccessful) attempts to acquire all requested locks.
140
141 One proposal for the timeout is to use ``2**tries`` seconds, where
142 ``tries`` is the number of unsuccessful tries.
143
144 In the demonstration before this would allow Operation C to continue
145 after Operation B unsuccessfully tried to acquire all locks and released
146 all acquired locks (``inst1``, ``inst2`` and ``inst3``) again.
147
148 Other solutions discussed
149 +++++++++++++++++++++++++
150
151 There was also some discussion on going one step further and extend the
152 job queue (see ``lib/jqueue.py``) to select the next task for a worker
153 depending on whether it can acquire the necessary locks. While this may
154 reduce the number of necessary worker threads and/or increase throughput
155 on large clusters with many jobs, it also brings many potential
156 problems, such as contention and increased memory usage, with it. As
157 this would be an extension of the changes proposed before it could be
158 implemented at a later point in time, but we decided to stay with the
159 simpler solution for now.
160
161 Implementation details
162 ++++++++++++++++++++++
163
164 ``SharedLock`` redesign
165 ^^^^^^^^^^^^^^^^^^^^^^^
166
167 The current design of ``SharedLock`` is not good for supporting timeouts
168 when acquiring a lock and there are also minor fairness issues in it. We
169 plan to address both with a redesign. A proof of concept implementation
170 was written and resulted in significantly simpler code.
171
172 Currently ``SharedLock`` uses two separate queues for shared and
173 exclusive acquires and waiters get to run in turns. This means if an
174 exclusive acquire is released, the lock will allow shared waiters to run
175 and vice versa.  Although it's still fair in the end there is a slight
176 bias towards shared waiters in the current implementation. The same
177 implementation with two shared queues can not support timeouts without
178 adding a lot of complexity.
179
180 Our proposed redesign changes ``SharedLock`` to have only one single
181 queue.  There will be one condition (see Condition_ for a note about
182 performance) in the queue per exclusive acquire and two for all shared
183 acquires (see below for an explanation). The maximum queue length will
184 always be ``2 + (number of exclusive acquires waiting)``. The number of
185 queue entries for shared acquires can vary from 0 to 2.
186
187 The two conditions for shared acquires are a bit special. They will be
188 used in turn. When the lock is instantiated, no conditions are in the
189 queue. As soon as the first shared acquire arrives (and there are
190 holder(s) or waiting acquires; see Acquire_), the active condition is
191 added to the queue. Until it becomes the topmost condition in the queue
192 and has been notified, any shared acquire is added to this active
193 condition. When the active condition is notified, the conditions are
194 swapped and further shared acquires are added to the previously inactive
195 condition (which has now become the active condition). After all waiters
196 on the previously active (now inactive) and now notified condition
197 received the notification, it is removed from the queue of pending
198 acquires.
199
200 This means shared acquires will skip any exclusive acquire in the queue.
201 We believe it's better to improve parallelization on operations only
202 asking for shared (or read-only) locks. Exclusive operations holding the
203 same lock can not be parallelized.
204
205
206 Acquire
207 *******
208
209 For exclusive acquires a new condition is created and appended to the
210 queue.  Shared acquires are added to the active condition for shared
211 acquires and if the condition is not yet on the queue, it's appended.
212
213 The next step is to wait for our condition to be on the top of the queue
214 (to guarantee fairness). If the timeout expired, we return to the caller
215 without acquiring the lock. On every notification we check whether the
216 lock has been deleted, in which case an error is returned to the caller.
217
218 The lock can be acquired if we're on top of the queue (there is no one
219 else ahead of us). For an exclusive acquire, there must not be other
220 exclusive or shared holders. For a shared acquire, there must not be an
221 exclusive holder.  If these conditions are all true, the lock is
222 acquired and we return to the caller. In any other case we wait again on
223 the condition.
224
225 If it was the last waiter on a condition, the condition is removed from
226 the queue.
227
228 Optimization: There's no need to touch the queue if there are no pending
229 acquires and no current holders. The caller can have the lock
230 immediately.
231
232 .. image:: design-2.1-lock-acquire.png
233
234
235 Release
236 *******
237
238 First the lock removes the caller from the internal owner list. If there
239 are pending acquires in the queue, the first (the oldest) condition is
240 notified.
241
242 If the first condition was the active condition for shared acquires, the
243 inactive condition will be made active. This ensures fairness with
244 exclusive locks by forcing consecutive shared acquires to wait in the
245 queue.
246
247 .. image:: design-2.1-lock-release.png
248
249
250 Delete
251 ******
252
253 The caller must either hold the lock in exclusive mode already or the
254 lock must be acquired in exclusive mode. Trying to delete a lock while
255 it's held in shared mode must fail.
256
257 After ensuring the lock is held in exclusive mode, the lock will mark
258 itself as deleted and continue to notify all pending acquires. They will
259 wake up, notice the deleted lock and return an error to the caller.
260
261
262 Condition
263 ^^^^^^^^^
264
265 Note: This is not necessary for the locking changes above, but it may be
266 a good optimization (pending performance tests).
267
268 The existing locking code in Ganeti 2.0 uses Python's built-in
269 ``threading.Condition`` class. Unfortunately ``Condition`` implements
270 timeouts by sleeping 1ms to 20ms between tries to acquire the condition
271 lock in non-blocking mode. This requires unnecessary context switches
272 and contention on the CPython GIL (Global Interpreter Lock).
273
274 By using POSIX pipes (see ``pipe(2)``) we can use the operating system's
275 support for timeouts on file descriptors (see ``select(2)``). A custom
276 condition class will have to be written for this.
277
278 On instantiation the class creates a pipe. After each notification the
279 previous pipe is abandoned and re-created (technically the old pipe
280 needs to stay around until all notifications have been delivered).
281
282 All waiting clients of the condition use ``select(2)`` or ``poll(2)`` to
283 wait for notifications, optionally with a timeout. A notification will
284 be signalled to the waiting clients by closing the pipe. If the pipe
285 wasn't closed during the timeout, the waiting function returns to its
286 caller nonetheless.
287
288
289 Node daemon availability
290 ~~~~~~~~~~~~~~~~~~~~~~~~
291
292 Current State and shortcomings
293 ++++++++++++++++++++++++++++++
294
295 Currently, when a Ganeti node suffers serious system disk damage, the
296 migration/failover of an instance may not correctly shutdown the virtual
297 machine on the broken node causing instances duplication. The ``gnt-node
298 powercycle`` command can be used to force a node reboot and thus to
299 avoid duplicated instances. This command relies on node daemon
300 availability, though, and thus can fail if the node daemon has some
301 pages swapped out of ram, for example.
302
303
304 Proposed changes
305 ++++++++++++++++
306
307 The proposed solution forces node daemon to run exclusively in RAM. It
308 uses python ctypes to to call ``mlockall(MCL_CURRENT | MCL_FUTURE)`` on
309 the node daemon process and all its children. In addition another log
310 handler has been implemented for node daemon to redirect to
311 ``/dev/console`` messages that cannot be written on the logfile.
312
313 With these changes node daemon can successfully run basic tasks such as
314 a powercycle request even when the system disk is heavily damaged and
315 reading/writing to disk fails constantly.
316
317
318 New Features
319 ------------
320
321 Automated Ganeti Cluster Merger
322 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
323
324 Current situation
325 +++++++++++++++++
326
327 Currently there's no easy way to merge two or more clusters together.
328 But in order to optimize resources this is a needed missing piece. The
329 goal of this design doc is to come up with a easy to use solution which
330 allows you to merge two or more cluster together.
331
332 Initial contact
333 +++++++++++++++
334
335 As the design of Ganeti is based on an autonomous system, Ganeti by
336 itself has no way to reach nodes outside of its cluster. To overcome
337 this situation we're required to prepare the cluster before we can go
338 ahead with the actual merge: We've to replace at least the ssh keys on
339 the affected nodes before we can do any operation within ``gnt-``
340 commands.
341
342 To make this a automated process we'll ask the user to provide us with
343 the root password of every cluster we've to merge. We use the password
344 to grab the current ``id_dsa`` key and then rely on that ssh key for any
345 further communication to be made until the cluster is fully merged.
346
347 Cluster merge
348 +++++++++++++
349
350 After initial contact we do the cluster merge:
351
352 1. Grab the list of nodes
353 2. On all nodes add our own ``id_dsa.pub`` key to ``authorized_keys``
354 3. Stop all instances running on the merging cluster
355 4. Disable ``ganeti-watcher`` as it tries to restart Ganeti daemons
356 5. Stop all Ganeti daemons on all merging nodes
357 6. Grab the ``config.data`` from the master of the merging cluster
358 7. Stop local ``ganeti-masterd``
359 8. Merge the config:
360
361    1. Open our own cluster ``config.data``
362    2. Open cluster ``config.data`` of the merging cluster
363    3. Grab all nodes of the merging cluster
364    4. Set ``master_candidate`` to false on all merging nodes
365    5. Add the nodes to our own cluster ``config.data``
366    6. Grab all the instances on the merging cluster
367    7. Adjust the port if the instance has drbd layout:
368
369       1. In ``logical_id`` (index 2)
370       2. In ``physical_id`` (index 1 and 3)
371
372    8. Add the instances to our own cluster ``config.data``
373
374 9. Start ``ganeti-masterd`` with ``--no-voting`` ``--yes-do-it``
375 10. ``gnt-node add --readd`` on all merging nodes
376 11. ``gnt-cluster redist-conf``
377 12. Restart ``ganeti-masterd`` normally
378 13. Enable ``ganeti-watcher`` again
379 14. Start all merging instances again
380
381 Rollback
382 ++++++++
383
384 Until we actually (re)add any nodes we can abort and rollback the merge
385 at any point. After merging the config, though, we've to get the backup
386 copy of ``config.data`` (from another master candidate node). And for
387 security reasons it's a good idea to undo ``id_dsa.pub`` distribution by
388 going on every affected node and remove the ``id_dsa.pub`` key again.
389 Also we've to keep in mind, that we've to start the Ganeti daemons and
390 starting up the instances again.
391
392 Verification
393 ++++++++++++
394
395 Last but not least we should verify that the merge was successful.
396 Therefore we run ``gnt-cluster verify``, which ensures that the cluster
397 overall is in a healthy state. Additional it's also possible to compare
398 the list of instances/nodes with a list made prior to the upgrade to
399 make sure we didn't lose any data/instance/node.
400
401 Appendix
402 ++++++++
403
404 cluster-merge.py
405 ^^^^^^^^^^^^^^^^
406
407 Used to merge the cluster config. This is a POC and might differ from
408 actual production code.
409
410 ::
411
412   #!/usr/bin/python
413
414   import sys
415   from ganeti import config
416   from ganeti import constants
417
418   c_mine = config.ConfigWriter(offline=True)
419   c_other = config.ConfigWriter(sys.argv[1])
420
421   fake_id = 0
422   for node in c_other.GetNodeList():
423     node_info = c_other.GetNodeInfo(node)
424     node_info.master_candidate = False
425     c_mine.AddNode(node_info, str(fake_id))
426     fake_id += 1
427
428   for instance in c_other.GetInstanceList():
429     instance_info = c_other.GetInstanceInfo(instance)
430     for dsk in instance_info.disks:
431       if dsk.dev_type in constants.LDS_DRBD:
432          port = c_mine.AllocatePort()
433          logical_id = list(dsk.logical_id)
434          logical_id[2] = port
435          dsk.logical_id = tuple(logical_id)
436          physical_id = list(dsk.physical_id)
437          physical_id[1] = physical_id[3] = port
438          dsk.physical_id = tuple(physical_id)
439     c_mine.AddInstance(instance_info, str(fake_id))
440     fake_id += 1
441
442
443 Feature changes
444 ---------------
445
446 Ganeti Confd
447 ~~~~~~~~~~~~
448
449 Current State and shortcomings
450 ++++++++++++++++++++++++++++++
451
452 In Ganeti 2.0 all nodes are equal, but some are more equal than others.
453 In particular they are divided between "master", "master candidates" and
454 "normal".  (Moreover they can be offline or drained, but this is not
455 important for the current discussion). In general the whole
456 configuration is only replicated to master candidates, and some partial
457 information is spread to all nodes via ssconf.
458
459 This change was done so that the most frequent Ganeti operations didn't
460 need to contact all nodes, and so clusters could become bigger. If we
461 want more information to be available on all nodes, we need to add more
462 ssconf values, which is counter-balancing the change, or to talk with
463 the master node, which is not designed to happen now, and requires its
464 availability.
465
466 Information such as the instance->primary_node mapping will be needed on
467 all nodes, and we also want to make sure services external to the
468 cluster can query this information as well. This information must be
469 available at all times, so we can't query it through RAPI, which would
470 be a single point of failure, as it's only available on the master.
471
472
473 Proposed changes
474 ++++++++++++++++
475
476 In order to allow fast and highly available access read-only to some
477 configuration values, we'll create a new ganeti-confd daemon, which will
478 run on master candidates. This daemon will talk via UDP, and
479 authenticate messages using HMAC with a cluster-wide shared key. This
480 key will be generated at cluster init time, and stored on the clusters
481 alongside the ganeti SSL keys, and readable only by root.
482
483 An interested client can query a value by making a request to a subset
484 of the cluster master candidates. It will then wait to get a few
485 responses, and use the one with the highest configuration serial number.
486 Since the configuration serial number is increased each time the ganeti
487 config is updated, and the serial number is included in all answers,
488 this can be used to make sure to use the most recent answer, in case
489 some master candidates are stale or in the middle of a configuration
490 update.
491
492 In order to prevent replay attacks queries will contain the current unix
493 timestamp according to the client, and the server will verify that its
494 timestamp is in the same 5 minutes range (this requires synchronized
495 clocks, which is a good idea anyway). Queries will also contain a "salt"
496 which they expect the answers to be sent with, and clients are supposed
497 to accept only answers which contain salt generated by them.
498
499 The configuration daemon will be able to answer simple queries such as:
500
501 - master candidates list
502 - master node
503 - offline nodes
504 - instance list
505 - instance primary nodes
506
507 Wire protocol
508 ^^^^^^^^^^^^^
509
510 A confd query will look like this, on the wire::
511
512   plj0{
513     "msg": "{\"type\": 1,
514              \"rsalt\": \"9aa6ce92-8336-11de-af38-001d093e835f\",
515              \"protocol\": 1,
516              \"query\": \"node1.example.com\"}\n",
517     "salt": "1249637704",
518     "hmac": "4a4139b2c3c5921f7e439469a0a45ad200aead0f"
519   }
520
521 ``plj0`` is a fourcc that details the message content. It stands for plain
522 json 0, and can be changed as we move on to different type of protocols
523 (for example protocol buffers, or encrypted json). What follows is a
524 json encoded string, with the following fields:
525
526 - ``msg`` contains a JSON-encoded query, its fields are:
527
528   - ``protocol``, integer, is the confd protocol version (initially
529     just ``constants.CONFD_PROTOCOL_VERSION``, with a value of 1)
530   - ``type``, integer, is the query type. For example "node role by
531     name" or "node primary ip by instance ip". Constants will be
532     provided for the actual available query types
533   - ``query`` is a multi-type field (depending on the ``type`` field):
534
535     - it can be missing, when the request is fully determined by the
536       ``type`` field
537     - it can contain a string which denotes the search key: for
538       example an IP, or a node name
539     - it can contain a dictionary, in which case the actual details
540       vary further per request type
541
542   - ``rsalt``, string, is the required response salt; the client must
543     use it to recognize which answer it's getting.
544
545 - ``salt`` must be the current unix timestamp, according to the
546   client; servers should refuse messages which have a wrong timing,
547   according to their configuration and clock
548 - ``hmac`` is an hmac signature of salt+msg, with the cluster hmac key
549
550 If an answer comes back (which is optional, since confd works over UDP)
551 it will be in this format::
552
553   plj0{
554     "msg": "{\"status\": 0,
555              \"answer\": 0,
556              \"serial\": 42,
557              \"protocol\": 1}\n",
558     "salt": "9aa6ce92-8336-11de-af38-001d093e835f",
559     "hmac": "aaeccc0dff9328fdf7967cb600b6a80a6a9332af"
560   }
561
562 Where:
563
564 - ``plj0`` the message type magic fourcc, as discussed above
565 - ``msg`` contains a JSON-encoded answer, its fields are:
566
567   - ``protocol``, integer, is the confd protocol version (initially
568     just constants.CONFD_PROTOCOL_VERSION, with a value of 1)
569   - ``status``, integer, is the error code; initially just ``0`` for
570     'ok' or ``1`` for 'error' (in which case answer contains an error
571     detail, rather than an answer), but in the future it may be
572     expanded to have more meanings (e.g. ``2`` if the answer is
573     compressed)
574   - ``answer``, is the actual answer; its type and meaning is query
575     specific: for example for "node primary ip by instance ip" queries
576     it will be a string containing an IP address, for "node role by
577     name" queries it will be an integer which encodes the role
578     (master, candidate, drained, offline) according to constants
579
580 - ``salt`` is the requested salt from the query; a client can use it
581   to recognize what query the answer is answering.
582 - ``hmac`` is an hmac signature of salt+msg, with the cluster hmac key
583
584
585 Redistribute Config
586 ~~~~~~~~~~~~~~~~~~~
587
588 Current State and shortcomings
589 ++++++++++++++++++++++++++++++
590
591 Currently LUClusterRedistConf triggers a copy of the updated
592 configuration file to all master candidates and of the ssconf files to
593 all nodes. There are other files which are maintained manually but which
594 are important to keep in sync. These are:
595
596 - rapi SSL key certificate file (rapi.pem) (on master candidates)
597 - rapi user/password file rapi_users (on master candidates)
598
599 Furthermore there are some files which are hypervisor specific but we
600 may want to keep in sync:
601
602 - the xen-hvm hypervisor uses one shared file for all vnc passwords, and
603   copies the file once, during node add. This design is subject to
604   revision to be able to have different passwords for different groups
605   of instances via the use of hypervisor parameters, and to allow
606   xen-hvm and kvm to use an equal system to provide password-protected
607   vnc sessions. In general, though, it would be useful if the vnc
608   password files were copied as well, to avoid unwanted vnc password
609   changes on instance failover/migrate.
610
611 Optionally the admin may want to also ship files such as the global
612 xend.conf file, and the network scripts to all nodes.
613
614 Proposed changes
615 ++++++++++++++++
616
617 RedistributeConfig will be changed to copy also the rapi files, and to
618 call every enabled hypervisor asking for a list of additional files to
619 copy. Users will have the possibility to populate a file containing a
620 list of files to be distributed; this file will be propagated as well.
621 Such solution is really simple to implement and it's easily usable by
622 scripts.
623
624 This code will be also shared (via tasklets or by other means, if
625 tasklets are not ready for 2.1) with the AddNode and SetNodeParams LUs
626 (so that the relevant files will be automatically shipped to new master
627 candidates as they are set).
628
629 VNC Console Password
630 ~~~~~~~~~~~~~~~~~~~~
631
632 Current State and shortcomings
633 ++++++++++++++++++++++++++++++
634
635 Currently just the xen-hvm hypervisor supports setting a password to
636 connect the the instances' VNC console, and has one common password
637 stored in a file.
638
639 This doesn't allow different passwords for different instances/groups of
640 instances, and makes it necessary to remember to copy the file around
641 the cluster when the password changes.
642
643 Proposed changes
644 ++++++++++++++++
645
646 We'll change the VNC password file to a vnc_password_file hypervisor
647 parameter.  This way it can have a cluster default, but also a different
648 value for each instance. The VNC enabled hypervisors (xen and kvm) will
649 publish all the password files in use through the cluster so that a
650 redistribute-config will ship them to all nodes (see the Redistribute
651 Config proposed changes above).
652
653 The current VNC_PASSWORD_FILE constant will be removed, but its value
654 will be used as the default HV_VNC_PASSWORD_FILE value, thus retaining
655 backwards compatibility with 2.0.
656
657 The code to export the list of VNC password files from the hypervisors
658 to RedistributeConfig will be shared between the KVM and xen-hvm
659 hypervisors.
660
661 Disk/Net parameters
662 ~~~~~~~~~~~~~~~~~~~
663
664 Current State and shortcomings
665 ++++++++++++++++++++++++++++++
666
667 Currently disks and network interfaces have a few tweakable options and
668 all the rest is left to a default we chose. We're finding that we need
669 more and more to tweak some of these parameters, for example to disable
670 barriers for DRBD devices, or allow striping for the LVM volumes.
671
672 Moreover for many of these parameters it will be nice to have
673 cluster-wide defaults, and then be able to change them per
674 disk/interface.
675
676 Proposed changes
677 ++++++++++++++++
678
679 We will add new cluster level diskparams and netparams, which will
680 contain all the tweakable parameters. All values which have a sensible
681 cluster-wide default will go into this new structure while parameters
682 which have unique values will not.
683
684 Example of network parameters:
685   - mode: bridge/route
686   - link: for mode "bridge" the bridge to connect to, for mode route it
687     can contain the routing table, or the destination interface
688
689 Example of disk parameters:
690   - stripe: lvm stripes
691   - stripe_size: lvm stripe size
692   - meta_flushes: drbd, enable/disable metadata "barriers"
693   - data_flushes: drbd, enable/disable data "barriers"
694
695 Some parameters are bound to be disk-type specific (drbd, vs lvm, vs
696 files) or hypervisor specific (nic models for example), but for now they
697 will all live in the same structure. Each component is supposed to
698 validate only the parameters it knows about, and ganeti itself will make
699 sure that no "globally unknown" parameters are added, and that no
700 parameters have overridden meanings for different components.
701
702 The parameters will be kept, as for the BEPARAMS into a "default"
703 category, which will allow us to expand on by creating instance
704 "classes" in the future.  Instance classes is not a feature we plan
705 implementing in 2.1, though.
706
707
708 Global hypervisor parameters
709 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~
710
711 Current State and shortcomings
712 ++++++++++++++++++++++++++++++
713
714 Currently all hypervisor parameters are modifiable both globally
715 (cluster level) and at instance level. However, there is no other
716 framework to held hypervisor-specific parameters, so if we want to add
717 a new class of hypervisor parameters that only makes sense on a global
718 level, we have to change the hvparams framework.
719
720 Proposed changes
721 ++++++++++++++++
722
723 We add a new (global, not per-hypervisor) list of parameters which are
724 not changeable on a per-instance level. The create, modify and query
725 instance operations are changed to not allow/show these parameters.
726
727 Furthermore, to allow transition of parameters to the global list, and
728 to allow cleanup of inadverdently-customised parameters, the
729 ``UpgradeConfig()`` method of instances will drop any such parameters
730 from their list of hvparams, such that a restart of the master daemon
731 is all that is needed for cleaning these up.
732
733 Also, the framework is simple enough that if we need to replicate it
734 at beparams level we can do so easily.
735
736
737 Non bridged instances support
738 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
739
740 Current State and shortcomings
741 ++++++++++++++++++++++++++++++
742
743 Currently each instance NIC must be connected to a bridge, and if the
744 bridge is not specified the default cluster one is used. This makes it
745 impossible to use the vif-route xen network scripts, or other
746 alternative mechanisms that don't need a bridge to work.
747
748 Proposed changes
749 ++++++++++++++++
750
751 The new "mode" network parameter will distinguish between bridged
752 interfaces and routed ones.
753
754 When mode is "bridge" the "link" parameter will contain the bridge the
755 instance should be connected to, effectively making things as today. The
756 value has been migrated from a nic field to a parameter to allow for an
757 easier manipulation of the cluster default.
758
759 When mode is "route" the ip field of the interface will become
760 mandatory, to allow for a route to be set. In the future we may want
761 also to accept multiple IPs or IP/mask values for this purpose. We will
762 evaluate possible meanings of the link parameter to signify a routing
763 table to be used, which would allow for insulation between instance
764 groups (as today happens for different bridges).
765
766 For now we won't add a parameter to specify which network script gets
767 called for which instance, so in a mixed cluster the network script must
768 be able to handle both cases. The default kvm vif script will be changed
769 to do so. (Xen doesn't have a ganeti provided script, so nothing will be
770 done for that hypervisor)
771
772 Introducing persistent UUIDs
773 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~
774
775 Current state and shortcomings
776 ++++++++++++++++++++++++++++++
777
778 Some objects in the Ganeti configurations are tracked by their name
779 while also supporting renames. This creates an extra difficulty,
780 because neither Ganeti nor external management tools can then track
781 the actual entity, and due to the name change it behaves like a new
782 one.
783
784 Proposed changes part 1
785 +++++++++++++++++++++++
786
787 We will change Ganeti to use UUIDs for entity tracking, but in a
788 staggered way. In 2.1, we will simply add an “uuid” attribute to each
789 of the instances, nodes and cluster itself. This will be reported on
790 instance creation for nodes, and on node adds for the nodes. It will
791 be of course avaiblable for querying via the OpNodeQuery/Instance and
792 cluster information, and via RAPI as well.
793
794 Note that Ganeti will not provide any way to change this attribute.
795
796 Upgrading from Ganeti 2.0 will automatically add an ‘uuid’ attribute
797 to all entities missing it.
798
799
800 Proposed changes part 2
801 +++++++++++++++++++++++
802
803 In the next release (e.g. 2.2), the tracking of objects will change
804 from the name to the UUID internally, and externally Ganeti will
805 accept both forms of identification; e.g. an RAPI call would be made
806 either against ``/2/instances/foo.bar`` or against
807 ``/2/instances/bb3b2e42…``. Since an FQDN must have at least a dot,
808 and dots are not valid characters in UUIDs, we will not have namespace
809 issues.
810
811 Another change here is that node identification (during cluster
812 operations/queries like master startup, “am I the master?” and
813 similar) could be done via UUIDs which is more stable than the current
814 hostname-based scheme.
815
816 Internal tracking refers to the way the configuration is stored; a
817 DRBD disk of an instance refers to the node name (so that IPs can be
818 changed easily), but this is still a problem for name changes; thus
819 these will be changed to point to the node UUID to ease renames.
820
821 The advantages of this change (after the second round of changes), is
822 that node rename becomes trivial, whereas today node rename would
823 require a complete lock of all instances.
824
825
826 Automated disk repairs infrastructure
827 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
828
829 Replacing defective disks in an automated fashion is quite difficult
830 with the current version of Ganeti. These changes will introduce
831 additional functionality and interfaces to simplify automating disk
832 replacements on a Ganeti node.
833
834 Fix node volume group
835 +++++++++++++++++++++
836
837 This is the most difficult addition, as it can lead to dataloss if it's
838 not properly safeguarded.
839
840 The operation must be done only when all the other nodes that have
841 instances in common with the target node are fine, i.e. this is the only
842 node with problems, and also we have to double-check that all instances
843 on this node have at least a good copy of the data.
844
845 This might mean that we have to enhance the GetMirrorStatus calls, and
846 introduce and a smarter version that can tell us more about the status
847 of an instance.
848
849 Stop allocation on a given PV
850 +++++++++++++++++++++++++++++
851
852 This is somewhat simple. First we need a "list PVs" opcode (and its
853 associated logical unit) and then a set PV status opcode/LU. These in
854 combination should allow both checking and changing the disk/PV status.
855
856 Instance disk status
857 ++++++++++++++++++++
858
859 This new opcode or opcode change must list the instance-disk-index and
860 node combinations of the instance together with their status. This will
861 allow determining what part of the instance is broken (if any).
862
863 Repair instance
864 +++++++++++++++
865
866 This new opcode/LU/RAPI call will run ``replace-disks -p`` as needed, in
867 order to fix the instance status. It only affects primary instances;
868 secondaries can just be moved away.
869
870 Migrate node
871 ++++++++++++
872
873 This new opcode/LU/RAPI call will take over the current ``gnt-node
874 migrate`` code and run migrate for all instances on the node.
875
876 Evacuate node
877 ++++++++++++++
878
879 This new opcode/LU/RAPI call will take over the current ``gnt-node
880 evacuate`` code and run replace-secondary with an iallocator script for
881 all instances on the node.
882
883
884 User-id pool
885 ~~~~~~~~~~~~
886
887 In order to allow running different processes under unique user-ids
888 on a node, we introduce the user-id pool concept.
889
890 The user-id pool is a cluster-wide configuration parameter.
891 It is a list of user-ids and/or user-id ranges that are reserved
892 for running Ganeti processes (including KVM instances).
893 The code guarantees that on a given node a given user-id is only
894 handed out if there is no other process running with that user-id.
895
896 Please note, that this can only be guaranteed if all processes in
897 the system - that run under a user-id belonging to the pool - are
898 started by reserving a user-id first. That can be accomplished
899 either by using the RequestUnusedUid() function to get an unused
900 user-id or by implementing the same locking mechanism.
901
902 Implementation
903 ++++++++++++++
904
905 The functions that are specific to the user-id pool feature are located
906 in a separate module: ``lib/uidpool.py``.
907
908 Storage
909 ^^^^^^^
910
911 The user-id pool is a single cluster parameter. It is stored in the
912 *Cluster* object under the ``uid_pool`` name as a list of integer
913 tuples. These tuples represent the boundaries of user-id ranges.
914 For single user-ids, the boundaries are equal.
915
916 The internal user-id pool representation is converted into a
917 string: a newline separated list of user-ids or user-id ranges.
918 This string representation is distributed to all the nodes via the
919 *ssconf* mechanism. This means that the user-id pool can be
920 accessed in a read-only way on any node without consulting the master
921 node or master candidate nodes.
922
923 Initial value
924 ^^^^^^^^^^^^^
925
926 The value of the user-id pool cluster parameter can be initialized
927 at cluster initialization time using the
928
929 ``gnt-cluster init --uid-pool <uid-pool definition> ...``
930
931 command.
932
933 As there is no sensible default value for the user-id pool parameter,
934 it is initialized to an empty list if no ``--uid-pool`` option is
935 supplied at cluster init time.
936
937 If the user-id pool is empty, the user-id pool feature is considered
938 to be disabled.
939
940 Manipulation
941 ^^^^^^^^^^^^
942
943 The user-id pool cluster parameter can be modified from the
944 command-line with the following commands:
945
946 - ``gnt-cluster modify --uid-pool <uid-pool definition>``
947 - ``gnt-cluster modify --add-uids <uid-pool definition>``
948 - ``gnt-cluster modify --remove-uids <uid-pool definition>``
949
950 The ``--uid-pool`` option overwrites the current setting with the
951 supplied ``<uid-pool definition>``, while
952 ``--add-uids``/``--remove-uids`` adds/removes the listed uids
953 or uid-ranges from the pool.
954
955 The ``<uid-pool definition>`` should be a comma-separated list of
956 user-ids or user-id ranges. A range should be defined by a lower and
957 a higher boundary. The boundaries should be separated with a dash.
958 The boundaries are inclusive.
959
960 The ``<uid-pool definition>`` is parsed into the internal
961 representation, sanity-checked and stored in the ``uid_pool``
962 attribute of the *Cluster* object.
963
964 It is also immediately converted into a string (formatted in the
965 input format) and distributed to all nodes via the *ssconf* mechanism.
966
967 Inspection
968 ^^^^^^^^^^
969
970 The current value of the user-id pool cluster parameter is printed
971 by the ``gnt-cluster info`` command.
972
973 The output format is accepted by the ``gnt-cluster modify --uid-pool``
974 command.
975
976 Locking
977 ^^^^^^^
978
979 The ``uidpool.py`` module provides a function (``RequestUnusedUid``)
980 for requesting an unused user-id from the pool.
981
982 This will try to find a random user-id that is not currently in use.
983 The algorithm is the following:
984
985 1) Randomize the list of user-ids in the user-id pool
986 2) Iterate over this randomized UID list
987 3) Create a lock file (it doesn't matter if it already exists)
988 4) Acquire an exclusive POSIX lock on the file, to provide mutual
989    exclusion for the following non-atomic operations
990 5) Check if there is a process in the system with the given UID
991 6) If there isn't, return the UID, otherwise unlock the file and
992    continue the iteration over the user-ids
993
994 The user can than start a new process with this user-id.
995 Once a process is successfully started, the exclusive POSIX lock can
996 be released, but the lock file will remain in the filesystem.
997 The presence of such a lock file means that the given user-id is most
998 probably in use. The lack of a uid lock file does not guarantee that
999 there are no processes with that user-id.
1000
1001 After acquiring the exclusive POSIX lock, ``RequestUnusedUid``
1002 always performs a check to see if there is a process running with the
1003 given uid.
1004
1005 A user-id can be returned to the pool, by calling the
1006 ``ReleaseUid`` function. This will remove the corresponding lock file.
1007 Note, that it doesn't check if there is any process still running
1008 with that user-id. The removal of the lock file only means that there
1009 are most probably no processes with the given user-id. This helps
1010 in speeding up the process of finding a user-id that is guaranteed to
1011 be unused.
1012
1013 There is a convenience function, called ``ExecWithUnusedUid`` that
1014 wraps the execution of a function (or any callable) that requires a
1015 unique user-id. ``ExecWithUnusedUid`` takes care of requesting an
1016 unused user-id and unlocking the lock file. It also automatically
1017 returns the user-id to the pool if the callable raises an exception.
1018
1019 Code examples
1020 +++++++++++++
1021
1022 Requesting a user-id from the pool:
1023
1024 ::
1025
1026   from ganeti import ssconf
1027   from ganeti import uidpool
1028
1029   # Get list of all user-ids in the uid-pool from ssconf
1030   ss = ssconf.SimpleStore()
1031   uid_pool = uidpool.ParseUidPool(ss.GetUidPool(), separator="\n")
1032   all_uids = set(uidpool.ExpandUidPool(uid_pool))
1033
1034   uid = uidpool.RequestUnusedUid(all_uids)
1035   try:
1036     <start a process with the UID>
1037     # Once the process is started, we can release the file lock
1038     uid.Unlock()
1039   except ..., err:
1040     # Return the UID to the pool
1041     uidpool.ReleaseUid(uid)
1042
1043
1044 Releasing a user-id:
1045
1046 ::
1047
1048   from ganeti import uidpool
1049
1050   uid = <get the UID the process is running under>
1051   <stop the process>
1052   uidpool.ReleaseUid(uid)
1053
1054
1055 External interface changes
1056 --------------------------
1057
1058 OS API
1059 ~~~~~~
1060
1061 The OS API of Ganeti 2.0 has been built with extensibility in mind.
1062 Since we pass everything as environment variables it's a lot easier to
1063 send new information to the OSes without breaking retrocompatibility.
1064 This section of the design outlines the proposed extensions to the API
1065 and their implementation.
1066
1067 API Version Compatibility Handling
1068 ++++++++++++++++++++++++++++++++++
1069
1070 In 2.1 there will be a new OS API version (eg. 15), which should be
1071 mostly compatible with api 10, except for some new added variables.
1072 Since it's easy not to pass some variables we'll be able to handle
1073 Ganeti 2.0 OSes by just filtering out the newly added piece of
1074 information. We will still encourage OSes to declare support for the new
1075 API after checking that the new variables don't provide any conflict for
1076 them, and we will drop api 10 support after ganeti 2.1 has released.
1077
1078 New Environment variables
1079 +++++++++++++++++++++++++
1080
1081 Some variables have never been added to the OS api but would definitely
1082 be useful for the OSes. We plan to add an INSTANCE_HYPERVISOR variable
1083 to allow the OS to make changes relevant to the virtualization the
1084 instance is going to use. Since this field is immutable for each
1085 instance, the os can tight the install without caring of making sure the
1086 instance can run under any virtualization technology.
1087
1088 We also want the OS to know the particular hypervisor parameters, to be
1089 able to customize the install even more.  Since the parameters can
1090 change, though, we will pass them only as an "FYI": if an OS ties some
1091 instance functionality to the value of a particular hypervisor parameter
1092 manual changes or a reinstall may be needed to adapt the instance to the
1093 new environment. This is not a regression as of today, because even if
1094 the OSes are left blind about this information, sometimes they still
1095 need to make compromises and cannot satisfy all possible parameter
1096 values.
1097
1098 OS Variants
1099 +++++++++++
1100
1101 Currently we are assisting to some degree of "os proliferation" just to
1102 change a simple installation behavior. This means that the same OS gets
1103 installed on the cluster multiple times, with different names, to
1104 customize just one installation behavior. Usually such OSes try to share
1105 as much as possible through symlinks, but this still causes
1106 complications on the user side, especially when multiple parameters must
1107 be cross-matched.
1108
1109 For example today if you want to install debian etch, lenny or squeeze
1110 you probably need to install the debootstrap OS multiple times, changing
1111 its configuration file, and calling it debootstrap-etch,
1112 debootstrap-lenny or debootstrap-squeeze. Furthermore if you have for
1113 example a "server" and a "development" environment which installs
1114 different packages/configuration files and must be available for all
1115 installs you'll probably end  up with deboostrap-etch-server,
1116 debootstrap-etch-dev, debootrap-lenny-server, debootstrap-lenny-dev,
1117 etc. Crossing more than two parameters quickly becomes not manageable.
1118
1119 In order to avoid this we plan to make OSes more customizable, by
1120 allowing each OS to declare a list of variants which can be used to
1121 customize it. The variants list is mandatory and must be written, one
1122 variant per line, in the new "variants.list" file inside the main os
1123 dir. At least one supported variant must be supported. When choosing the
1124 OS exactly one variant will have to be specified, and will be encoded in
1125 the os name as <OS-name>+<variant>. As for today it will be possible to
1126 change an instance's OS at creation or install time.
1127
1128 The 2.1 OS list will be the combination of each OS, plus its supported
1129 variants. This will cause the name name proliferation to remain, but at
1130 least the internal OS code will be simplified to just parsing the passed
1131 variant, without the need for symlinks or code duplication.
1132
1133 Also we expect the OSes to declare only "interesting" variants, but to
1134 accept some non-declared ones which a user will be able to pass in by
1135 overriding the checks ganeti does. This will be useful for allowing some
1136 variations to be used without polluting the OS list (per-OS
1137 documentation should list all supported variants). If a variant which is
1138 not internally supported is forced through, the OS scripts should abort.
1139
1140 In the future (post 2.1) we may want to move to full fledged parameters
1141 all orthogonal to each other (for example "architecture" (i386, amd64),
1142 "suite" (lenny, squeeze, ...), etc). (As opposed to the variant, which
1143 is a single parameter, and you need a different variant for all the set
1144 of combinations you want to support).  In this case we envision the
1145 variants to be moved inside of Ganeti and be associated with lists
1146 parameter->values associations, which will then be passed to the OS.
1147
1148
1149 IAllocator changes
1150 ~~~~~~~~~~~~~~~~~~
1151
1152 Current State and shortcomings
1153 ++++++++++++++++++++++++++++++
1154
1155 The iallocator interface allows creation of instances without manually
1156 specifying nodes, but instead by specifying plugins which will do the
1157 required computations and produce a valid node list.
1158
1159 However, the interface is quite akward to use:
1160
1161 - one cannot set a 'default' iallocator script
1162 - one cannot use it to easily test if allocation would succeed
1163 - some new functionality, such as rebalancing clusters and calculating
1164   capacity estimates is needed
1165
1166 Proposed changes
1167 ++++++++++++++++
1168
1169 There are two area of improvements proposed:
1170
1171 - improving the use of the current interface
1172 - extending the IAllocator API to cover more automation
1173
1174
1175 Default iallocator names
1176 ^^^^^^^^^^^^^^^^^^^^^^^^
1177
1178 The cluster will hold, for each type of iallocator, a (possibly empty)
1179 list of modules that will be used automatically.
1180
1181 If the list is empty, the behaviour will remain the same.
1182
1183 If the list has one entry, then ganeti will behave as if
1184 '--iallocator' was specifyed on the command line. I.e. use this
1185 allocator by default. If the user however passed nodes, those will be
1186 used in preference.
1187
1188 If the list has multiple entries, they will be tried in order until
1189 one gives a successful answer.
1190
1191 Dry-run allocation
1192 ^^^^^^^^^^^^^^^^^^
1193
1194 The create instance LU will get a new 'dry-run' option that will just
1195 simulate the placement, and return the chosen node-lists after running
1196 all the usual checks.
1197
1198 Cluster balancing
1199 ^^^^^^^^^^^^^^^^^
1200
1201 Instance add/removals/moves can create a situation where load on the
1202 nodes is not spread equally. For this, a new iallocator mode will be
1203 implemented called ``balance`` in which the plugin, given the current
1204 cluster state, and a maximum number of operations, will need to
1205 compute the instance relocations needed in order to achieve a "better"
1206 (for whatever the script believes it's better) cluster.
1207
1208 Cluster capacity calculation
1209 ^^^^^^^^^^^^^^^^^^^^^^^^^^^^
1210
1211 In this mode, called ``capacity``, given an instance specification and
1212 the current cluster state (similar to the ``allocate`` mode), the
1213 plugin needs to return:
1214
1215 - how many instances can be allocated on the cluster with that
1216   specification
1217 - on which nodes these will be allocated (in order)
1218
1219 .. vim: set textwidth=72 :