kvm: Use -display none rather than -nographic
[ganeti-local] / doc / design-monitoring-agent.rst
1 =======================
2 Ganeti monitoring agent
3 =======================
4
5 .. contents:: :depth: 4
6
7 This is a design document detailing the implementation of a Ganeti
8 monitoring agent report system, that can be queried by a monitoring
9 system to calculate health information for a Ganeti cluster.
10
11 Current state and shortcomings
12 ==============================
13
14 There is currently no monitoring support in Ganeti. While we don't want
15 to build something like Nagios or Pacemaker as part of Ganeti, it would
16 be useful if such tools could easily extract information from a Ganeti
17 machine in order to take actions (example actions include logging an
18 outage for future reporting or alerting a person or system about it).
19
20 Proposed changes
21 ================
22
23 Each Ganeti node should export a status page that can be queried by a
24 monitoring system. Such status page will be exported on a network port
25 and will be encoded in JSON (simple text) over HTTP.
26
27 The choice of json is obvious as we already depend on it in Ganeti and
28 thus we don't need to add extra libraries to use it, as opposed to what
29 would happen for XML or some other markup format.
30
31 Location of agent report
32 ------------------------
33
34 The report will be available from all nodes, and be concerned for all
35 node-local resources. This allows more real-time information to be
36 available, at the cost of querying all nodes.
37
38 Information reported
39 --------------------
40
41 The monitoring agent system will report on the following basic information:
42
43 - Instance status
44 - Instance disk status
45 - Status of storage for instances
46 - Ganeti daemons status, CPU usage, memory footprint
47 - Hypervisor resources report (memory, CPU, network interfaces)
48 - Node OS resources report (memory, CPU, network interfaces)
49 - Information from a plugin system
50
51 Instance status
52 +++++++++++++++
53
54 At the moment each node knows which instances are running on it, which
55 instances it is primary for, but not the cause why an instance might not
56 be running. On the other hand we don't want to distribute full instance
57 "admin" status information to all nodes, because of the performance
58 impact this would have.
59
60 As such we propose that:
61
62 - Any operation that can affect instance status will have an optional
63   "reason" attached to it (at opcode level). This can be used for
64   example to distinguish an admin request, from a scheduled maintenance
65   or an automated tool's work. If this reason is not passed, Ganeti will
66   just use the information it has about the source of the request: for
67   example a cli shutdown operation will have "cli:shutdown" as a reason,
68   a cli failover operation will have "cli:failover". Operations coming
69   from the remote API will use "rapi" instead of "cli". Of course
70   setting a real site-specific reason is still preferred.
71 - RPCs that affect the instance status will be changed so that the
72   "reason" and the version of the config object they ran on is passed to
73   them. They will then export the new expected instance status, together
74   with the associated reason and object version to the status report
75   system, which then will export those themselves.
76
77 Monitoring and auditing systems can then use the reason to understand
78 the cause of an instance status, and they can use the object version to
79 understand the freshness of their data even in the absence of an atomic
80 cross-node reporting: for example if they see an instance "up" on a node
81 after seeing it running on a previous one, they can compare these values
82 to understand which data is freshest, and repoll the "older" node. Of
83 course if they keep seeing this status this represents an error (either
84 an instance continuously "flapping" between nodes, or an instance is
85 constantly up on more than one), which should be reported and acted
86 upon.
87
88 The instance status will be on each node, for the instances it is
89 primary for and will contain at least:
90
91 - The instance name
92 - The instance UUID (stable on name change)
93 - The instance running status (up or down)
94 - The uptime, as detected by the hypervisor
95 - The timestamp of last known change
96 - The timestamp of when the status was last checked (see caching, below)
97 - The last known reason for change, if any
98
99 More information about all the fields and their type will be available
100 in the "Format of the report" section.
101
102 Note that as soon as a node knows it's not the primary anymore for an
103 instance it will stop reporting status for it: this means the instance
104 will either disappear, if it has been deleted, or appear on another
105 node, if it's been moved.
106
107 Instance Disk status
108 ++++++++++++++++++++
109
110 As for the instance status Ganeti has now only partial information about
111 its instance disks: in particular each node is unaware of the disk to
112 instance mapping, that exists only on the master.
113
114 For this design doc we plan to fix this by changing all RPCs that create
115 a backend storage or that put an already existing one in use and passing
116 the relevant instance to the node. The node can then export these to the
117 status reporting tool.
118
119 While we haven't implemented these RPC changes yet, we'll use confd to
120 fetch this information in the data collector.
121
122 Since Ganeti supports many type of disks for instances (drbd, rbd,
123 plain, file) we will export both a "generic" status which will work for
124 any type of disk and will be very opaque (at minimum just an "healthy"
125 or "error" state, plus perhaps some human readable comment and a
126 "per-type" status which will explain more about the internal details but
127 will not be compatible between different storage types (and will for
128 example export the drbd connection status, sync, and so on).
129
130 Status of storage for instances
131 +++++++++++++++++++++++++++++++
132
133 The node will also be reporting on all storage types it knows about for
134 the current node (this is right now hardcoded to the enabled storage
135 types, and in the future tied to the enabled storage pools for the
136 nodegroup). For this kind of information also we will report both a
137 generic health status (healthy or error) for each type of storage, and
138 some more generic statistics (free space, used space, total visible
139 space). In addition type specific information can be exported: for
140 example, in case of error, the nature of the error can be disclosed as a
141 type specific information. Examples of these are "backend pv
142 unavailable" for lvm storage, "unreachable" for network based storage or
143 "filesystem error" for filesystem based implementations.
144
145 Ganeti daemons status
146 +++++++++++++++++++++
147
148 Ganeti will report what information it has about its own daemons: this
149 includes memory usage, uptime, CPU usage. This should allow identifying
150 possible problems with the Ganeti system itself: for example memory
151 leaks, crashes and high resource utilization should be evident by
152 analyzing this information.
153
154 Ganeti daemons will also be able to export extra internal information to
155 the status reporting, through the plugin system (see below).
156
157 Hypervisor resources report
158 +++++++++++++++++++++++++++
159
160 Each hypervisor has a view of system resources that sometimes is
161 different than the one the OS sees (for example in Xen the Node OS,
162 running as Dom0, has access to only part of those resources). In this
163 section we'll report all information we can in a "non hypervisor
164 specific" way. Each hypervisor can then add extra specific information
165 that is not generic enough be abstracted.
166
167 Node OS resources report
168 ++++++++++++++++++++++++
169
170 Since Ganeti assumes it's running on Linux, it's useful to export some
171 basic information as seen by the host system. This includes number and
172 status of CPUs, memory, filesystems and network intefaces as well as the
173 version of components Ganeti interacts with (Linux, drbd, hypervisor,
174 etc).
175
176 Note that we won't go into any hardware specific details (e.g. querying a
177 node RAID is outside the scope of this, and can be implemented as a
178 plugin) but we can easily just report the information above, since it's
179 standard enough across all systems.
180
181 Plugin system
182 +++++++++++++
183
184 The monitoring system will be equipped with a plugin system that can
185 export specific local information through it. The plugin system will be
186 in the form of either scripts whose output will be inserted in the
187 report, plain text files which will be inserted into the report, or
188 local unix or network sockets from which the information has to be read.
189 This should allow most flexibility for implementing an efficient system,
190 while being able to keep it as simple as possible.
191
192 The plugin system is expected to be used by local installations to
193 export any installation specific information that they want to be
194 monitored, about either hardware or software on their systems.
195
196
197 Format of the query
198 -------------------
199
200 The query will be an HTTP GET request on a particular port. At the
201 beginning it will only be possible to query the full status report.
202
203
204 Format of the report
205 --------------------
206
207 The report of the will be in JSON format, and it will present an array
208 of report objects.
209 Each report object will be produced by a specific data collector.
210 Each report object includes some mandatory fields, to be provided by all
211 the data collectors, and a field to contain data collector-specific
212 data.
213
214 Here follows a minimal example of a report::
215
216   [
217   {
218       "name" : "TheCollectorIdentifier",
219       "version" : "1.2",
220       "format_version" : 1,
221       "timestamp" : 1351607182000000000,
222       "data" : { "plugin_specific_data" : "go_here" }
223   },
224   {
225       "name" : "AnotherDataCollector",
226       "version" : "B",
227       "format_version" : 7,
228       "timestamp" : 1351609526123854000,
229       "data" : { "plugin_specific" : "data",
230                  "some_late_data" : { "timestamp" : "SPECIFIC_TIME",
231                                       ... }
232                }
233   }
234   ]
235
236 Here is the description of the mandatory fields of each object:
237
238 name
239   the name of the data collector that produced this part of the report.
240   It is supposed to be unique inside a report.
241
242 version
243   the version of the data collector that produces this part of the
244   report. Built-in data collectors (as opposed to those implemented as
245   plugins) should have "B" as the version number.
246
247 format_version
248   the format of what is represented in the "data" field for each data
249   collector might change over time. Every time this happens, the
250   format_version should be changed, so that who reads the report knows
251   what format to expect, and how to correctly interpret it.
252
253 timestamp
254   the time when the reported data were gathered. Is has to be expressed
255   in nanoseconds since the unix epoch (0:00:00 January 01, 1970). If not
256   enough precision is available (or needed) it can be padded with
257   zeroes. If a report object needs multiple timestamps, it can add more
258   and/or override this one inside its own "data" section.
259
260 data
261   this field contains all the data generated by the data collector, in
262   its own independently defined format. The monitoring agent could check
263   this syntactically (according to the JSON specifications) but not
264   semantically.
265
266
267 Data collectors
268 ---------------
269
270 In order to ease testing as well as to make it simple to reuse this
271 subsystem it will be possible to run just the "data collectors" on each
272 node without passing through the agent daemon. Each data collector will
273 report specific data about its subsystem and will be documented
274 separately.
275
276 If a data collector is run independently, it should print on stdout its
277 report, according to the format corresponding to a single data collector
278 report object, as described in the previous paragraph.
279
280
281 Mode of operation
282 -----------------
283
284 In order to be able to report information fast the monitoring agent
285 daemon will keep an in-memory or on-disk cache of the status, which will
286 be returned when queries are made. The status system will then
287 periodically check resources to make sure the status is up to date.
288
289 Different parts of the report will be queried at different speeds. These
290 will depend on:
291 - how often they vary (or we expect them to vary)
292 - how fast they are to query
293 - how important their freshness is
294
295 Of course the last parameter is installation specific, and while we'll
296 try to have defaults, it will be configurable. The first two instead we
297 can use adaptively to query a certain resource faster or slower
298 depending on those two parameters.
299
300
301 Implementation place
302 --------------------
303
304 The status daemon will be implemented as a standalone Haskell daemon. In
305 the future it should be easy to merge multiple daemons into one with
306 multiple entry points, should we find out it saves resources and doesn't
307 impact functionality.
308
309 The libekg library should be looked at for easily providing metrics in
310 json format.
311
312
313 Implementation order
314 --------------------
315
316 We will implement the agent system in this order:
317
318 - initial example data collectors (eg. for drbd and instance status.
319   Data collector-specific report format TBD).
320 - initial daemon for exporting data
321 - RPC updates for instance status reasons and disk to instance mapping
322 - more data collectors
323 - cache layer for the daemon (if needed)
324
325
326 Future work
327 ===========
328
329 As a future step it can be useful to "centralize" all this reporting
330 data on a single place. This for example can be just the master node, or
331 all the master candidates. We will evaluate doing this after the first
332 node-local version has been developed and tested.
333
334 Another possible change is replacing the "read-only" RPCs with queries
335 to the agent system, thus having only one way of collecting information
336 from the nodes from a monitoring system and for Ganeti itself.
337
338 One extra feature we may need is a way to query for only sub-parts of
339 the report (eg. instances status only). This can be done by passing
340 arguments to the HTTP GET, which will be defined when we get to this
341 funtionality.
342
343 Finally the :doc:`autorepair system design <design-autorepair>`. system
344 (see its design) can be expanded to use the monitoring agent system as a
345 source of information to decide which repairs it can perform.
346
347 .. vim: set textwidth=72 :
348 .. Local Variables:
349 .. mode: rst