History | View | Annotate | Download (595 Bytes)
PPC: e500: Select MPIC v4.2 on ppce500 platform
The compatible string is changed to fsl,mpic on all e500 platforms, toadvertise the existence of BRR1. This matches what the device tree willhave on real hardware.
With MPIC v4.2 max_cpu can be increased from 15 to 32....
PPC: E500: Move PCI slot information into params
We have a params struct that allows us to expose differences betweene500 machine models. Include PCI slot information there, so we can havedifferent machines with different PCI slot topology.
Signed-off-by: Alexander Graf <agraf@suse.de>
PPC: e500: split mpc8544ds machine from generic e500 code
Currently the only mpc8544ds-ism that is factored out istoplevel compatible and model. In the future the generic e500code is expected to become more generic.