Statistics
| Branch: | Tag: | Revision:

root / lib @ 04c4330c

Name Size
  hypervisor
  rapi
__init__.py 791 Bytes
backend.py 55.6 kB
bdev.py 49.4 kB
bootstrap.py 11.9 kB
cli.py 20.3 kB
cmdlib.py 178 kB
config.py 23.2 kB
constants.py 8.6 kB
errors.py 5.3 kB
http.py 6.9 kB
jqueue.py 19.7 kB
jstore.py 3.8 kB
locking.py 29.3 kB
logger.py 2.8 kB
luxi.py 8.6 kB
mcpu.py 12.6 kB
objects.py 21.6 kB
opcodes.py 13.8 kB
rpc.py 18.3 kB
serializer.py 1.6 kB
ssconf.py 6.9 kB
ssh.py 6.7 kB
utils.py 34.1 kB
workerpool.py 9 kB

Latest revisions

# Date Author Comment
04c4330c 09/02/2008 11:42 am Alexander Schreiber

merge r1540 from branches/ganeti/ganeti-1.2

Allow access to HVM serial console

Reviewed-by: imsnah

34b6ab97 09/01/2008 07:05 pm Alexander Schreiber

merge r1539 from branches/ganeti/ganeti-1.2

Display VNC console port in gnt-instance info.

Reviewed-by: iustinp

5bc84f33 09/01/2008 05:12 pm Alexander Schreiber

merge r1538 from branches/ganeti/ganeti-1.2

Check HVM device type on instance modify as well.

Reviewed-by: imsnah

cfefe007 09/01/2008 02:37 pm Guido Trotter

Check memory size before setting it

With this change when a user asks for a new memory size for an instance,
the number is checked instead of just applied. The operation fails only
if the instance would not be able to restart on its primary node, but
generates warnings should it be impossible to failover the instance or...

4300c4b6 09/01/2008 02:37 pm Guido Trotter

Pass the force param to SetInstanceParms

It was already allowed in gnt-instance modify, but ignored.
It will be used to force skipping parameter checks.

This is a forward-port from branches/ganeti-1.2

Original-Reviewed-by: imsnah
Reviewed-by: iustinp

5397e0b7 08/29/2008 07:17 pm Alexander Schreiber

Merge r1536 from branches/ganeti/ganeti-1.2

Add HVM device type flags 2/3

Reviewed-by: ultrotter

b77ba978 08/29/2008 06:04 pm Michael Hanselmann

utils.SplitTime: Fix rounding of milliseconds

Reported by Iustin.

It used to return this:

utils.SplitTime(1234.999999999999)

(1234, 1000)

while it should've returned this:

utils.SplitTime(1234.999999999999)

(1235, 0)

Reviewed-by: ultrotter

b894f5a8 08/29/2008 06:01 pm Alexander Schreiber

merge r1535 from branches/ganeti/ganeti-1.2

Add HVM device type flags 1/4

Reviewed-by: ultrotter

5c735209 08/29/2008 04:42 pm Iustin Pop

Make WaitForJobChanges deal with long jobs

This patch alters the WaitForJobChanges luxi-RPC call to have a
configurable timeout, so that the call behaves nicely with long jobs
that have no update.

We do this by adding a timeout parameter in the RPC call, and returning...

3fc175f0 08/29/2008 03:47 pm Alexander Schreiber

merge r997 from branches/ganeti/ganeti-1.2

Fix gnt-instance modify for HVM parameters

This patch makes gnt-instance modify work again for the advanced
HVM parameters after it was broken by other changes.

Reviewed-by: ultrotter

View revisions

Also available in: Atom